Glow Discharge Mass Spectrometry for Cobalt Alloys Analysis

被引:0
|
作者
Itoh, Shinji [1 ]
Yamada, Katsura [1 ]
Kobayashi, Takeshi [1 ]
机构
[1] Natl Inst Mat Sci, Mat Anal Stn, Tsukuba, Ibaraki 3050047, Japan
关键词
relative sensitivity factor; cobalt alloys; glow discharge mass spectrometry; fundamental parameter/X-ray fluorescence spectrometry;
D O I
10.2116/bunsekikagaku.58.27
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A comparison of results obtained using argon/glow discharge mass spectrometry (Ar/GD-MS) and fundamental parameter/X-ray fluorescence analysis (FP/XRF) was made by analyzing of cobalt (Co) alloys. The relative sensitivity factors (RSF) used for GD-MS quantitative analysis were determined using six commercial Co alloy standard reference materials. The analysis objects comprised 16 elements contained in Co alloys: C, Al, Si, P, S, Ti, Cr, Mn, Fe, Ni, Cu, Nb, Mo, Sn, La, and W. A glow-discharge cell for disk samples was used. A sample mask made from Ta, a part of the anode, was employed; it had an internal diameter of 12 mm. The discharge parameters were 1 kV and 3 mA. Samples were put on a liquid sample CLIP with an adherent 6.3-mu m-thick polypropylene film and subjected to a FP/XRF measurement. The sensitivity coefficients (K(ij)) of XRF for Co alloys were determined through measuring identical standard substances, such as GD-MS, and processing thereof using UQ5 software. A commercial Co alloy, Haynes 188, was subjected to chemical analysis; the GD-MS, chemical analysis, and FP/XRF results were compared. The FP/XRF results of the main components (Cr, Fe, Ni, and W) agreed well with the GD-MS and chemical analysis results. The analytical accuracy was satisfactory as 0.18% (Cr) similar to 0.46% (W) in RSD. However, some overestimation occurred for minor, elements such as Cu and La, at low concentrations, where RSD was 10 similar to 17%. On the other hand, the GD-MS results agreed well with results of chemical analysis obtained from P and S at the trace impurity level, minor components, to main components. The analytical accuracy of GD-MS was shown to be within 2% as RSD for most elements, from main components, such as Cr (RSD : 1.2%), Ni (1.0%), and W (0.89%), to elements of trace impurity level, like S (4.5%), including minor components.
引用
收藏
页码:27 / 31
页数:5
相关论文
共 50 条
  • [21] Compositions of Co – Cr – Mo Alloys Examined by Glow-Discharge Mass Spectrometry
    Vladimir D. Kurochkin
    Powder Metallurgy and Metal Ceramics, 2004, 43 : 411 - 416
  • [22] GLOW-DISCHARGE MASS-SPECTROMETRY
    HARRISON, WW
    BENTZ, BL
    PROGRESS IN ANALYTICAL SPECTROSCOPY, 1988, 11 (01): : 53 - 110
  • [23] GLOW-DISCHARGE MASS-SPECTROMETRY
    HARRISON, WW
    HESS, KR
    MARCUS, RK
    KING, FL
    ANALYTICAL CHEMISTRY, 1986, 58 (02) : A341 - &
  • [24] Analysis of high purity antimony by glow discharge quadrupole mass spectrometry
    Shekhar, R
    Krishna, MVB
    Arunachalam, J
    Gangadharan, S
    ATOMIC SPECTROSCOPY, 1999, 20 (01) : 25 - 29
  • [25] ANALYSIS OF SOLUTION RESIDUES BY GLOW-DISCHARGE MASS-SPECTROMETRY
    BARSHICK, CM
    DUCKWORTH, DC
    SMITH, DH
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (01) : 47 - 53
  • [26] APPLICATION OF GLOW-DISCHARGE MASS-SPECTROMETRY TO THE STEEL ANALYSIS
    CHIBA, K
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1986, 72 (05): : S413 - S413
  • [27] Analysis of Particle Hafnium by Direct Current Glow Discharge Mass Spectrometry
    Qian Rong
    Siqinbilige
    Zhuo Shang-Jun
    Shen Ru-Xiang
    Sheng Cheng
    Gan Fu-Xi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (05) : 700 - 704
  • [28] Round robin analysis of aluminium using glow discharge mass spectrometry
    Venzago, C
    Ohanessian-Pierrard, L
    Kasik, M
    Collisi, U
    Baude, S
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (03) : 189 - 193
  • [29] APPLICATION OF GLOW-DISCHARGE MASS-SPECTROMETRY TO THE STEEL ANALYSIS
    CHIBA, K
    ONO, A
    SAEKI, M
    TRANSACTIONS OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1986, 26 (09) : B296 - B296
  • [30] ANALYSIS OF PLATINUM POWDER BY GLOW-DISCHARGE MASS-SPECTROMETRY
    VANSTRAATEN, M
    SWENTERS, K
    GIJBELS, R
    VERLINDEN, J
    ADRIAENSSENS, E
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (12) : 1389 - 1397