Revision total hip arthroplasty for large medial (protrusio) defects with a rim-fit cementless acetabular component

被引:18
|
作者
Hansen, E [1 ]
Ries, MD [1 ]
机构
[1] Univ Calif San Francisco, Dept Orthopaed Surg, San Francisco, CA 94143 USA
来源
JOURNAL OF ARTHROPLASTY | 2006年 / 21卷 / 01期
关键词
revision; acetabular; total hip arthroplasty; protrusio; medial; defect;
D O I
10.1016/j.arth.2005.01.022
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Seventeen patients (19 hips) with protrusio acetabuli resulting from a failed total hip arthroplasty, large medial bone defect, and an intact bony rim were treated with an oversized cementless acetabular component and medial morcelized allograft. An average of 55% of the revision component was not supported by host bone. At an average follow-tip of 2.8 (range 2-6) years, none of the acetabular components required revision for loosening. The average cup position preoperatively was 10.5 min medial to Kohler's line and postoperatively was 6.8 mm lateral to Kohler's line. Despite very large medial defects, reconstructions with this technique remained stable.
引用
收藏
页码:72 / 79
页数:8
相关论文
共 50 条
  • [41] Cementless total hip arthroplasty in the treatment after acetabular fractures
    Salama W.
    Ditto P.
    Mousa S.
    Khalefa A.
    Sleem A.
    Ravera L.
    Masse A.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (1) : 59 - 64
  • [42] Total hip arthroplasty with expansion acetabular component
    Tuekenmez, Mehmet
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2007, 27 (04): : 528 - 532
  • [43] Acetabular revision for aseptic loosening in total hip arthroplasty using cementless cup and impacted morselized allograft
    Parratte, S.
    Argenson, J.-N.
    Flecher, X.
    Aubaniac, J.-M.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (03): : 255 - 263
  • [44] Large Acetabular Defects Can be Managed with Cementless Revision Components
    Paxton, E. Scott, Jr.
    Keeney, James A.
    Maloney, William J.
    Clohisy, John C.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) : 483 - 493
  • [45] Reconstruction at a high hip center in acetabular revision surgery using a cementless acetabular component
    Harris, WH
    ORTHOPEDICS, 1998, 21 (09) : 991 - 992
  • [46] Computational modeling of revision total hip arthroplasty involving acetabular defects: A systematic review
    Hopkins, Daniel
    Callary, Stuart A.
    Solomon, L. B.
    Woodford, Sarah C.
    Lee, Peter V. S.
    Ackland, David C.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2024, 42 (10) : 2249 - 2263
  • [47] Radiographic evaluation of the zurich cementless total hip acetabular component
    Hanson, Steven P.
    Peck, Jeffrey N.
    Berry, Clifford R.
    Graham, John
    Stevens, Gary
    VETERINARY SURGERY, 2006, 35 (06) : 550 - 558
  • [48] Cernentless acetabular reconstruction in revision total hip arthroplasty
    Della Valle, CJ
    Berger, RA
    Rosenberg, AG
    Galante, JO
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (420) : 96 - 100
  • [49] Midterm Survivorship After Revision Total Hip Arthroplasty With a Custom Triflange Acetabular Component
    Gladnick, Brian P.
    Fehring, Keith A.
    Odum, Susan M.
    Christie, Michael J.
    DeBoer, David K.
    Fehring, Thomas K.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02): : 500 - 504
  • [50] Acetabular revision of total hip arthroplasty using a press-fit dual mobility cup
    Massin, P.
    Besnier, L.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (01) : 8 - 12