摘要
Background: The zone of calcified cartilage (ZCC) plays an important role in the pathogenesis of osteoarthritis (OA) but has never been imaged in vivo with magnetic resonance (MR) imaging techniques. We investigated the feasibility of direct imaging of the ZCC in both cadaveric whole knee specimens and in vivo healthy knees using a 3-dimensional ultrashort echo time cones (3D UTE-Cones) sequence on a clinical 3T scanner. Methods: In all, 12 cadaveric knee joints and 10 in vivo healthy were collected. At a 3T MR scanner with an 8-channel knee coil, a fat-saturated 3D dual-echo UTE-Cones sequence was used to image the ZCC, following with a short rectangular pulse excitation and 3D spiral sampling with conical view ordering. The regions of interests (ROIs) were delineated by a blinded observer. Single-component T2* and T2 values were calculated from fat-saturated 3D dual-echo UTE-Cones and a Carr-Purcell-Meiboom-Gill (T2 C:PMG) data using a semi-automated MATLAB code. Results: The single-exponential fitting curve of ZCC was accurately obtained with R2 of 0.989. For keen joint samples, the ZCC has a short T2* ranging from 0.62 to 2.55 ms, with the mean +/- standard deviation (SD) of 1.49 +/- 0.66 ms, and with 95% confidence intervals (CI) of 1.20-1.78 ms. For volunteers, the short T2* ranges from 0.93 to 3.52 ms, with the mean +SD of 2.09 +/- 0.56 ms, and the 95% CI is 1.43 to 2.74 ms in ZCC. Conclusions: The high-resolution 3D UTE-Cones sequence might be used to directly image ZCC in the human knee joint on a clinical 3T scanner with a scan time of more than 10 min. Using this non-invasive technique, the T2* relaxation time of the ZCC can he further detected.
引用
收藏
页码:562 / 568
页数:7
相关论文
共 50 条
  • [11] Magnetic resonance ultrashort echo time spin-echo imaging of the deepest layers of articular cartilage
    GAO Song
    DU Jiang
    WANG Fei
    BAO ShangLian
    Science China(Life Sciences), 2013, 56 (07) : 672 - 674
  • [12] Magnetic resonance ultrashort echo time spin-echo imaging of the deepest layers of articular cartilage
    GAO Song
    DU Jiang
    WANG Fei
    BAO ShangLian
    Science China(Life Sciences) , 2013, (07) : 672 - 674
  • [13] Magnetic resonance ultrashort echo time spin-echo imaging of the deepest layers of articular cartilage
    Gao Song
    Du Jiang
    Wang Fei
    Bao ShangLian
    SCIENCE CHINA-LIFE SCIENCES, 2013, 56 (07) : 672 - 674
  • [14] Magnetic resonance ultrashort echo time spin-echo imaging of the deepest layers of articular cartilage
    Song Gao
    Jiang Du
    Fei Wang
    ShangLian Bao
    Science China Life Sciences, 2013, 56 : 672 - 674
  • [15] A 3-DIMENSIONAL REPRESENTATION OF AN ATHLETIC FEMALE KNEE-JOINT USING MAGNETIC-RESONANCE-IMAGING
    STEELE, JR
    BASU, A
    JOB, A
    MEDICAL ENGINEERING & PHYSICS, 1994, 16 (05) : 363 - 369
  • [16] Functional magnetic resonance imaging with an ultrashort echo time
    Kim, Min-Ji
    Jahng, Geon-Ho
    Lee, Soo-Yeol
    Ryu, Chang-Woo
    MEDICAL PHYSICS, 2013, 40 (02)
  • [17] Simultaneous Quantitative Susceptibility Mapping of Articular Cartilage and Cortical Bone of Human Knee Joint Using Ultrashort Echo Time Sequences
    Zhang, Ming
    Li, Zhihui
    Wang, Hanqi
    Chen, Tongtong
    Lu, Yong
    Yan, Fuhua
    Zhang, Yuyao
    Wei, Hongjiang
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13
  • [18] Single- and Bicomponent Analyses of T2? Relaxation in Knee Tendon and Ligament by Using 3D Ultrashort Echo Time Cones (UTE Cones) Magnetic Resonance Imaging
    Liu, Jin
    Nazaran, Amin
    Ma, Yajun
    Chen, Haimei
    Zhu, Yanchun
    Du, Jiang
    Li, Shaolin
    Zhou, Quan
    Zhao, Yinghua
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [19] Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients
    Konstantinos G. Zeimpekis
    Julia Geiger
    Florian Wiesinger
    Gaspar Delso
    Christian J. Kellenberger
    Pediatric Radiology, 2021, 51 : 57 - 65
  • [20] Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients
    Zeimpekis, Konstantinos G.
    Geiger, Julia
    Wiesinger, Florian
    Delso, Gaspar
    Kellenberger, Christian J.
    PEDIATRIC RADIOLOGY, 2021, 51 (01) : 57 - 65