Magnetic resonance imaging of the zone of calcified cartilage in the knee joint using 3-dimensional ultrashort echo time cones sequences

被引:8
|
作者
Liu, Jin [1 ]
Wei, Yang [2 ]
Ma, Ya-Jun [3 ]
Zhu, Yan-Chun [3 ]
Zhou, Quan [1 ]
Zhao, Ying-Hua [1 ,3 ]
机构
[1] Southern Med Univ, Dept Radiol, Affiliated Hosp 3, Acad Orthoped, Guangzhou 510630, Guangdong, Peoples R China
[2] Southern Med Univ, Guangdong Prov Key Lab Med Image Proc, Sch Biomed Engn, Guangzhou 510515, Guangdong, Peoples R China
[3] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
关键词
Ultrashort echo time; T2*relaxation time; Zone of calcified cartilage; Articular cartilage; ARTICULAR-CARTILAGE; SUBCHONDRAL BONE; RESOLUTION;
D O I
10.1097/CM9.0000000000000103
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The zone of calcified cartilage (ZCC) plays an important role in the pathogenesis of osteoarthritis (OA) but has never been imaged in vivo with magnetic resonance (MR) imaging techniques. We investigated the feasibility of direct imaging of the ZCC in both cadaveric whole knee specimens and in vivo healthy knees using a 3-dimensional ultrashort echo time cones (3D UTE-Cones) sequence on a clinical 3T scanner. Methods: In all, 12 cadaveric knee joints and 10 in vivo healthy were collected. At a 3T MR scanner with an 8-channel knee coil, a fat-saturated 3D dual-echo UTE-Cones sequence was used to image the ZCC, following with a short rectangular pulse excitation and 3D spiral sampling with conical view ordering. The regions of interests (ROIs) were delineated by a blinded observer. Single-component T2* and T2 values were calculated from fat-saturated 3D dual-echo UTE-Cones and a Carr-Purcell-Meiboom-Gill (T2 C:PMG) data using a semi-automated MATLAB code. Results: The single-exponential fitting curve of ZCC was accurately obtained with R2 of 0.989. For keen joint samples, the ZCC has a short T2* ranging from 0.62 to 2.55 ms, with the mean +/- standard deviation (SD) of 1.49 +/- 0.66 ms, and with 95% confidence intervals (CI) of 1.20-1.78 ms. For volunteers, the short T2* ranges from 0.93 to 3.52 ms, with the mean +SD of 2.09 +/- 0.56 ms, and the 95% CI is 1.43 to 2.74 ms in ZCC. Conclusions: The high-resolution 3D UTE-Cones sequence might be used to directly image ZCC in the human knee joint on a clinical 3T scanner with a scan time of more than 10 min. Using this non-invasive technique, the T2* relaxation time of the ZCC can he further detected.
引用
收藏
页码:562 / 568
页数:7
相关论文
共 50 条
  • [1] Magnetic resonance imaging of the zone of calcified cartilage in the knee joint using 3-dimensional ultrashort echo time cones sequences
    Liu Jin
    Wei Yang
    Ma Ya-Jun
    Zhu Yan-Chun
    Zhou Quan
    Zhao Ying-Hua
    中华医学杂志英文版, 2019, 132 (05) : 562 - 568
  • [2] The value of magnetic resonance ultrashort echo time imaging to evaluate non-calcified cartilage of the knee joint and its damage
    Hu, Yawen
    Xu, Jun
    Zhou, Ruizhi
    Xu, Qi
    Sun, Shiqing
    Wang, Wenzhe
    Chen, Haisong
    HELIYON, 2023, 9 (03)
  • [3] Magnetic resonance imaging (MRI) of articular cartilage of the knee using ultrashort echo time (uTE) sequences with spiral acquisition
    Goto, Hajimu
    Fujii, Masahiko
    Iwama, Yuki
    Aoyama, Nobukazu
    Ohno, Yoshiharu
    Sugimura, Kazuro
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2012, 56 (03) : 318 - 323
  • [4] Detection of Repair of the Zone of Calcified Cartilage with Osteoarthritis through Mesenchymal Stem Cells by Ultrashort Echo Time Magnetic Resonance Imaging
    Zhou Quan
    Li ShaoLin
    Ma YaJun
    Tal Vicki de
    Li Wei
    Zhao YingHua
    Department of Radiology Third Affiliated Hospital of Southern Medical University Academy of Orthopedics Guangdong Province Guangzhou Guangdong China
    Department of Radiology Third Affiliated Hospital of Southern Medical University Academy of Orthopedics Guangdong Province Guangzhou Guangdong China
    Department of Medical Imaging The Fifth Affiliated Hospital of Sun Yatsen University Zhuhai Guangdong China
    Department of Radiology University of California San Diego CA USA
    中华医学杂志英文版, 2018, 131 (09) : 1092 - 1098
  • [5] Detection of Repair of the Zone of Calcified Cartilage with Osteoarthritis through Mesenchymal Stem Cells by Ultrashort Echo Time Magnetic Resonance Imaging
    Zhou, Quan
    Li, Shao-Lin
    Ma, Ya-Jun
    de Ta, Vicki
    Li, Wei
    Zhao, Ying-Hua
    CHINESE MEDICAL JOURNAL, 2018, 131 (09) : 1092 - 1098
  • [6] Quantitative three-dimensional ultrashort echo time cones imaging of the knee joint with motion correction
    Wu, Mei
    Zhao, Wei
    Wan, Lidi
    Kakos, Lena
    Li, Liang
    Jerban, Saeed
    Jang, Hyungseok
    Chang, Eric Y.
    Du, Jiang
    Ma, Ya-Jun
    NMR IN BIOMEDICINE, 2020, 33 (01)
  • [7] Fast quantitative three-dimensional ultrashort echo time (UTE) Cones magnetic resonance imaging of major tissues in the knee joint using extended sprial sampling
    Wan, Lidi
    Ma, Yajun
    Yang, Jiawei
    Jerban, Saeed
    Searleman, Adam C.
    Carl, Michael
    Le, Nicole
    Chang, Eric Y.
    Tang, Guangyu
    Du, Jiang
    NMR IN BIOMEDICINE, 2020, 33 (10)
  • [8] Assessment of mechanical properties of articular cartilage with quantitative three-dimensional ultrashort echo time (UTE) cones magnetic resonance imaging
    Namiranian, Behnam
    Jerban, Saeed
    Ma, Yajun
    Dorthe, Erik W.
    Masoud-Afsahi, Amir
    Wong, Jonathan
    Wei, Zhao
    Chen, Yanjun
    D'Lima, Darryl
    Chang, Eric Y.
    Du, Jiang
    JOURNAL OF BIOMECHANICS, 2020, 113
  • [9] Three-dimensional ultrashort echo time cones (3D UTE-Cones) magnetic resonance imaging of entheses and tendons
    Chen, Bimin
    Zhao, Yinghua
    Cheng, Xin
    Ma, Yajun
    Chang, Eric Y.
    Kavanaugh, Arthur
    Liu, Sirun
    Du, Jiang
    MAGNETIC RESONANCE IMAGING, 2018, 49 : 4 - 9
  • [10] MAGNETIC-RESONANCE IN CARTILAGINOUS LESIONS OF THE KNEE-JOINT WITH 3-DIMENSIONAL GRADIENT-ECHO IMAGING
    REISER, MF
    BONGARTZ, G
    ERLEMANN, R
    STROBEL, M
    PAULY, T
    GAEBERT, K
    STOEBER, U
    PETERS, PE
    SKELETAL RADIOLOGY, 1988, 17 (07) : 465 - 471