A Biomechanical Comparison of Ipsilateral and Contralateral Pedicle Screw Placement for Modified Triangular Osteosynthesis in Unstable Pelvic Fractures

被引:24
|
作者
Toogood, Paul [1 ]
McDonald, Erik [1 ]
Pekmezci, Murat [1 ]
机构
[1] Univ Calif San Francisco, San Francisco Gen Hosp, Dept Orthopaed, San Francisco, CA 94143 USA
关键词
SACRAL FRACTURES; INTERNAL-FIXATION;
D O I
10.1097/BOT.0b013e3182787d54
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: Iliosacral fixation of unstable pelvic fractures does not produce enough stability to allow for immediate postoperative weight bearing. Triangular osteosynthesis creates additional resistance to vertical displacement and rotation. A disadvantage is the loss of the L5/S1 motion segment. We propose a modification of the standard triangular osteosynthesis construct in which the contralateral S1 pedicle is used. As the ipsilateral L5 pedicle is unavailable for fixation in a saw-bones composite pelvic model, we compared ipsilateral and contralateral S1 pedicle screw constructs. We hypothesized that ipsilateral and contralateral S1 pedicle screw constructs would demonstrate no difference in displacement or rotation.Methods: Seven saw bones pelvic models were tested. A 5-mm vertical fracture gap was created through the left sacrum while the pubic symphysis was completely dissociated. Each pelvis was tested sequentially in 4 triangular osteosynthesis configurations: ipsilateral S1 screw with anterior plate, contralateral S1 screw with anterior plate, contralateral S1 screw without anterior plate, and ipsilateral S1 screw without anterior plate. Specimens were cyclically loaded from 100-200 N at 0.25 Hz for 25 cycles and then loaded up to 300 N at 10 mm/min while displacement and rotation at the sacral and pubic fracture sites were measured.Results: There was no difference in any of the displacement measures between ipsilateral and contralateral constructs. When comparing rotation, the contralateral configuration experienced significantly less rotation than the ipsilateral configuration with and without the anterior plate applied.Conclusions: Within the limitations of the current model, contralateral S1 constructs for modified triangular osteosynthesis were biomechanically equal to ipsilateral constructs in preventing displacement and superior in preventing rotation.
引用
收藏
页码:515 / 520
页数:6
相关论文
共 50 条
  • [21] Biomechanical comparison of sagittal-parallel versus non-parallel pedicle screw placement
    Farshad, Mazda
    Farshad-Amacker, Nadja A.
    Bachmann, Elias
    Snedeker, Jess G.
    Schmid, Samuel L.
    ACTA NEUROCHIRURGICA, 2014, 156 (11) : 2147 - 2151
  • [22] Biomechanical comparison of sagittal-parallel versus non-parallel pedicle screw placement
    Mazda Farshad
    Nadja A. Farshad-Amacker
    Elias Bachmann
    Jess G. Snedeker
    Samuel L. Schmid
    Acta Neurochirurgica, 2014, 156 : 2147 - 2151
  • [23] Minimally invasive treatment of unstable pelvic ring injuries with modified pedicle screw-rod fixator
    Wu, Xiao-Tian
    Liu, Zuo-Qing
    Fu, Wen-Qin
    Zhao, Shan
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2018, 46 (01) : 368 - 380
  • [24] Computed Tomography-Guided C2 Pedicle Screw Placement for Treatment of Unstable Hangman Fractures
    Singh, Pankaj Kumar
    Garg, Kanwaljeet
    Sawarkar, Duttaraj
    Agarwal, Deepak
    Satyarthee, Guru Dutta
    Gupta, Deepak
    Sinha, Sumit
    Kale, Shashank Sarad
    Sharma, Bhawani Shankar
    SPINE, 2014, 39 (18) : E1058 - E1065
  • [25] Robotic guidance for percutaneous placement of triangular osteosynthesis in vertically unstable sacrum fractures: a single-center retrospective study
    Liu, Zhao-Jie
    Gu, Ya
    Jia, Jian
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [26] Robotic guidance for percutaneous placement of triangular osteosynthesis in vertically unstable sacrum fractures: a single-center retrospective study
    Zhao-Jie Liu
    Ya Gu
    Jian Jia
    Journal of Orthopaedic Surgery and Research, 18
  • [27] Novel unilateral C1 double screw and ipsilateral C2 pedicle screw placement combined with contralateral laminar screw–rod fixation for atlantoaxial instability
    Lei Shi
    Kai Shen
    Rui Deng
    Zheng-Jian Yan
    Kai-Lu Liang
    Liang Chen
    Zhen-Yong Ke
    Zhong-Liang Deng
    European Spine Journal, 2019, 28 : 362 - 369
  • [28] A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures
    Sascha Rausch
    Kajetan Klos
    Uwe Wolf
    Marc Gras
    Paul Simons
    Steffen Brodt
    Markus Windolf
    Boyko Gueorguiev
    International Orthopaedics, 2014, 38 : 1705 - 1710
  • [29] A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures
    Rausch, Sascha
    Klos, Kajetan
    Wolf, Uwe
    Gras, Marc
    Simons, Paul
    Brodt, Steffen
    Windolf, Markus
    Gueorguiev, Boyko
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (08) : 1705 - 1710
  • [30] Biomechanical Comparison of Different Pedicle Screw Fixations for Thoracolumbar Burst Fractures using Finite Element Method
    Wang, Dongmei
    Shi, Dufang
    Li, Xilei
    Dong, Jian
    Wang, Chunhui
    Chen, Shanguang
    MATERIALS AND COMPUTATIONAL MECHANICS, PTS 1-3, 2012, 117-119 : 699 - +