A Biomechanical Comparison of Ipsilateral and Contralateral Pedicle Screw Placement for Modified Triangular Osteosynthesis in Unstable Pelvic Fractures

被引:24
|
作者
Toogood, Paul [1 ]
McDonald, Erik [1 ]
Pekmezci, Murat [1 ]
机构
[1] Univ Calif San Francisco, San Francisco Gen Hosp, Dept Orthopaed, San Francisco, CA 94143 USA
关键词
SACRAL FRACTURES; INTERNAL-FIXATION;
D O I
10.1097/BOT.0b013e3182787d54
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: Iliosacral fixation of unstable pelvic fractures does not produce enough stability to allow for immediate postoperative weight bearing. Triangular osteosynthesis creates additional resistance to vertical displacement and rotation. A disadvantage is the loss of the L5/S1 motion segment. We propose a modification of the standard triangular osteosynthesis construct in which the contralateral S1 pedicle is used. As the ipsilateral L5 pedicle is unavailable for fixation in a saw-bones composite pelvic model, we compared ipsilateral and contralateral S1 pedicle screw constructs. We hypothesized that ipsilateral and contralateral S1 pedicle screw constructs would demonstrate no difference in displacement or rotation.Methods: Seven saw bones pelvic models were tested. A 5-mm vertical fracture gap was created through the left sacrum while the pubic symphysis was completely dissociated. Each pelvis was tested sequentially in 4 triangular osteosynthesis configurations: ipsilateral S1 screw with anterior plate, contralateral S1 screw with anterior plate, contralateral S1 screw without anterior plate, and ipsilateral S1 screw without anterior plate. Specimens were cyclically loaded from 100-200 N at 0.25 Hz for 25 cycles and then loaded up to 300 N at 10 mm/min while displacement and rotation at the sacral and pubic fracture sites were measured.Results: There was no difference in any of the displacement measures between ipsilateral and contralateral constructs. When comparing rotation, the contralateral configuration experienced significantly less rotation than the ipsilateral configuration with and without the anterior plate applied.Conclusions: Within the limitations of the current model, contralateral S1 constructs for modified triangular osteosynthesis were biomechanically equal to ipsilateral constructs in preventing displacement and superior in preventing rotation.
引用
收藏
页码:515 / 520
页数:6
相关论文
共 50 条
  • [1] A Modified Triangular Osteosynthesis Protocol for the Rod and Pedicle Screw Fixation of Vertical Unstable Sacral Fractures
    Tian, Dawei
    Guo, Xiaojun
    Liu, Na
    Wang, Bo
    He, Hongsheng
    Xiong, Min
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2021, 15 (03): : 485 - 493
  • [2] Biomechanical comparison of sacroiliac screw techniques for unstable pelvic ring fractures
    van Zwienen, CMA
    van den Bosch, EW
    Snijders, CJ
    Kleinrensink, GJ
    van Vugt, AB
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (09) : 589 - 595
  • [3] Biomechanical Study of Posterior Pelvic Fixations in Vertically Unstable Sacral Fractures: An Alternative to Triangular Osteosynthesis
    Chaiyamongkol, Weera
    Kritsaneephaiboon, Apipop
    Bintachitt, Piyawat
    Suwannaphisit, Sitthiphong
    Tangtrakulwanich, Boonsin
    ASIAN SPINE JOURNAL, 2018, 12 (06) : 967 - 972
  • [4] Sacroiliac versus transiliac–transsacral screw osteosynthesis in osteoporotic pelvic fractures: a biomechanical comparison
    Raffael Cintean
    Cornelius Fritzsche
    Ivan Zderic
    Boyko Gueorguiev-Rüegg
    Florian Gebhard
    Konrad Schütze
    European Journal of Trauma and Emergency Surgery, 2023, 49 : 2553 - 2560
  • [5] BIOMECHANICAL COMPARISON OF TRANS-SACRAL AND TRIANGULAR OSTEOSYNTHESIS IN A VERTICALLY UNSTABLE PELVIC FRACTURE MODEL
    Zamorano, David P.
    Min, Kyong S.
    Wahba, George
    Garcia, Ivan
    Bahtia, Nitin N.
    Lee, Thay Q.
    PROCEEDINGS OF THE 4TH FRONTIERS IN BIOMEDICAL DEVICES CONFERENCE AND EXPOSITION - 2009, 2009, : 105 - 106
  • [6] Triangular osteosynthesis and iliosacral screw fixation for unstable sacral fractures: A cadaveric and biomechanical evaluation under cyclic loads
    Schildhauer, TA
    Ledoux, WR
    Chapman, JR
    Henley, MB
    Tencer, AF
    Routt, MLC
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (01) : 22 - 31
  • [7] Sacroiliac versus transiliac-transsacral screw osteosynthesis in osteoporotic pelvic fractures: a biomechanical comparison
    Cintean, Raffael
    Fritzsche, Cornelius
    Zderic, Ivan
    Gueorguiev-Rueegg, Boyko
    Gebhard, Florian
    Schuetze, Konrad
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2023, 49 (06) : 2553 - 2560
  • [8] Ipsilateral pedicle screw placement with contralateral percutaneous facet screws: Early results with an alternative in lumbar arthrodesis
    Rhiew, Richard B.
    Manjila, Sunil
    Lozen, Andrew M.
    Hong, David
    Guthikonda, Murali
    Rengachary, S. S.
    OPEN ACCESS SURGERY, 2009, 2 : 1 - 4
  • [9] Biomechanical comparison of four triangular osteosynthesis fixations for unilateral vertical sacral fractures
    Ma, Yupeng
    Zhao, Yong
    Hong, Huanyu
    Huang, Tao
    Li, Yu
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [10] Effect of pedicle screw placement into the fractured vertebra in management of unstable thoracolumbar and lumbar fractures
    Guduru, Aditya Vardhan
    Keerthi, Ishwara
    Sujir, Premjit
    Jain, Manesh Kumar
    Sodavarapu, Praveen
    INTERNATIONAL JOURNAL OF BURNS AND TRAUMA, 2022, 12 (04): : 139 - 148