False Data Injection Attack Detection based on Hilbert-Huang Transform in AC Smart Islands

被引:24
|
作者
Dehghani, Moslem [1 ]
Ghiasi, Mohammad [1 ]
Niknam, Taher [1 ]
Kavousi-Fard, Abdollah [1 ]
Padmanaban, Sanjeevikumar [2 ]
机构
[1] Shiraz Univ Technol, Dept Elect & Elect Engn, Shiraz 7155713876, Iran
[2] Aalborg Univ, Dept Energy Technol, DK-6700 Esbjerg, Denmark
来源
IEEE ACCESS | 2020年 / 8卷 / 08期
关键词
Transforms; Sensors; Power measurement; Mathematical model; Power system reliability; Phasor measurement units; Reliability; False data injection attack; Hilbert-Huang transform; smart island; AC system;
D O I
10.1109/ACCESS.2020.3027782
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In Smart Island (SI) systems, operators of power distribution system usually utilize actual-time measurement information as the Advanced Metering Infrastructure (AMI) to have an accurate, efficient, advanced control and monitor of whole their system. SI system can be vulnerable to complicated information integrity attacks such as False Data Injection Attack (FDIA) on some equipment including sensors and controllers, which can generate misleading operational decision in the system. Hence, lack of detailed research in the evaluation of power system that links the FDIAs with system stability is felt, and it will be important for both assessment of the effect of cyber-attack and taking preventive protection measures. In this regards, time-frequency-based differential approach is proposed for SI cyber-attack detection according to non-stationary signal assessment. In this paper, non-stationary signal processing approach of Hilbert-Huang Transform (HHT) is performed for the FDIA detection in several case studies. Since various critical case studies with a small FDIA in data where accurate and efficient detection can be a challenge, the simulation results confirm the efficiency of HHT approach and the proposed detection frame is compared with shallow model. In this research, the configuration of the SI test case is developed in the MATLAB software with several Distributed Generations (DGs). As a result, it is found that the HHT approach is completely efficient and reliable for FDIA detection target in AC-SI. The simulation results verify that the proposed model is able to achieve accuracy rate of 93.17% and can detect FDIAs less than 50 ms from cyber-attack starting in different kind of scenarios.
引用
收藏
页码:179002 / 179017
页数:16
相关论文
共 50 条
  • [31] Induction machine bearing faults detection based on Hilbert-Huang transform
    20154701578356
    (1) ISEN Brest, EA 4325 LBMS, Brest, France; (2) University of Brest, EA 4325 LBMS, Brest, France, 1600, Federal University of Mato Grosso do Sul (UFMS); Federal University of Rio de Janeiro (UFRJ); State University of Rio de Janeiro (UERJ); The Institute of Electrical and Electronics Engineers Industrial Electronics Society (IEEE IES) (Institute of Electrical and Electronics Engineers Inc., United States):
  • [32] Research on the QRS complex detection algorithm based on Hilbert-Huang transform
    Xing, Hongyan
    Huang, Minsong
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2009, 30 (07): : 1469 - 1475
  • [33] The Detection of Low Frequency Oscillation Based on the Hilbert-Huang Transform Method
    Li, Kuan
    Tian, Junqiang
    Li, Congcong
    Liu, Meng
    Yang, Chao
    Zhang, Guohui
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 1376 - 1379
  • [34] Ship Power Quality Detection based on Improved Hilbert-Huang Transform
    Su, Yuxiang
    Liu, Guoping
    Li, Lin
    Shen, Xiaoqun
    JOURNAL OF COMPUTERS, 2012, 7 (08) : 1990 - 1997
  • [35] Terahertz Spectral Fingerprints Detection with Hilbert-Huang Transform
    Su, Yunpeng
    Zheng, Xiaoping
    Deng, Xiaojiao
    Deng, Yuqiang
    2017 42ND INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2017,
  • [36] The Application of Hilbert-Huang Transform in Power Quality Detection
    Zhang Rui
    Zhu Run-xia
    Wang Tian-bo
    PROCEEDINGS OF 2013 2ND INTERNATIONAL CONFERENCE ON MEASUREMENT, INFORMATION AND CONTROL (ICMIC 2013), VOLS 1 & 2, 2013, : 983 - 986
  • [37] Induction Machine Bearing Faults Detection based on Hilbert-Huang Transform
    Elbouchikhi, Elhoussin
    Choqueuse, Vincent
    Trachi, Youness
    Benbouzid, Mohamed
    2015 IEEE 24TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2015, : 843 - 848
  • [38] Flutter Test Data Processing Based on Improved Hilbert-Huang Transform
    Zheng, Hua
    Liu, Junhao
    Duan, Shiqiang
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2018, 2018
  • [39] An application of Hilbert-Huang Transform to handle terrain data
    Chien, Chin
    Huang, Liang-Hsiung
    Chang, Cheng-Wei
    Journal of the Chinese Institute of Civil and Hydraulic Engineering, 2010, 22 (04): : 375 - 386
  • [40] Detection of Doppler embolic signals with Hilbert-Huang transform
    Hao, Dongmei
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 412 - 415