A Method for Determining Optimal Mean Airway Pressure in High-Frequency Oscillatory Ventilation

被引:8
|
作者
Casserly, Brian [1 ,2 ]
McCool, F. Dennis [1 ]
Sethi, Jigme M. [1 ]
Kawar, Eyad [1 ]
Read, Richard [3 ]
Levy, Mitchell M. [3 ]
机构
[1] Brown Univ, Mem Hosp Rhode Isl, Div Pulm Crit Care & Sleep Med, Pawtucket, RI 02860 USA
[2] Midwestern Reg Hosp, Limerick, Ireland
[3] Rhode Isl Hosp, Div Pulm Crit Care & Sleep Med, Providence, RI USA
关键词
Mean airway pressure; High-frequency oscillatory ventilation; Acute respiratory distress syndrome; RESPIRATORY-DISTRESS-SYNDROME; END-EXPIRATORY PRESSURE; ACUTE LUNG INJURY; CONVENTIONAL VENTILATION; MATHEMATICAL-MODEL; PULMONARY-EDEMA; TIDAL VOLUME; TRIAL; RECRUITMENT; ADULTS;
D O I
10.1007/s00408-012-9434-4
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
"Optimal" mean airway pressure (MAP) during high-frequency oscillatory ventilation (HFOV) can be defined as the pressure that allows for maximal alveolar recruitment while minimizing alveolar overdistension. Choosing a MAP near or just below the point of maximal curvature (PMC) of the volume-pressure characteristics of the lung can serve as a guide to avoid overdistention during HFOV, while simultaneously preventing derecruitment. The purpose of this study was to assess whether optimal MAP at the PMC can be determined by using measures of PaO2 in patients with acute respiratory distress syndrome (ARDS) undergoing HFOV. We prospectively studied seven patients with ARDS who underwent HFOV after failed conventional ventilation. In addition, 11 healthy subjects were studied to validate measurements of changes in end-expiratory lung volume (a dagger EELV) using magnetometers. Using this validated method, plots of a dagger EELV and MAP were constructed during decremental changes in MAP following a recruitment maneuver in seven ventilated patients with ARDS. The PMC was defined as the point where the slope of the a dagger EELV versus MAP curve acutely changed. The MAP at the PMC was compared to that determined from plots of PaO2 versus MAP. In the healthy cohort, measurements of a dagger EELV obtained by magnetometry approximated the line of identity when compared to those obtained by spirometry. The MAP determined using either the a dagger EELV or PaO2 techniques were identical in all seven HFOV ventilated patients. Additionally, there was a significant correlation between the MAP associated changes in PaO2 and the MAP associated changes in a dagger EELV (p < 0.001). The finding that MAP at the PMC is the same whether determined by measures of a dagger EELV or PaO2 suggest that bedside measures PaO2 may provide an acceptable surrogate for measures of EELV when determining "optimal" MAP during HFOV.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 50 条
  • [41] TRACHEOBRONCHIAL INJURY WITH HIGH-FREQUENCY OSCILLATORY VENTILATION AND HIGH-FREQUENCY FLOW INTERRUPTION COMPARED WITH CONVENTIONAL POSITIVE PRESSURE VENTILATION
    WISWELL, TE
    CLARK, RH
    DELEMOS, RA
    COALSON, JJ
    PEDIATRIC RESEARCH, 1987, 21 (04) : A470 - A470
  • [42] Optimal mean airway pressure during high-frequency oscillation - Predicted by the pressure-volume curve
    Goddon, S
    Fujino, Y
    Hromi, JM
    Kacmarek, RM
    ANESTHESIOLOGY, 2001, 94 (05) : 862 - 869
  • [43] The effect of mean airway pressure (Paw) on dead space tidal volume ratio (VD/VT) during high-frequency oscillatory ventilation (HFOV).
    Anwar, MU
    Kesser, KC
    Clark, RH
    PEDIATRIC RESEARCH, 1996, 39 (04) : 1138 - 1138
  • [44] Deviation of tracheal pressure from airway opening pressure during high-frequency oscillatory ventilation in a porcine lung model
    Johannes, Amelie
    Zollhoefer, Bernd
    Eujen, Ulrike
    Kredel, Markus
    Rauch, Stefan
    Roewer, Norbert
    Muellenbach, Ralf M.
    EXPERIMENTAL LUNG RESEARCH, 2013, 39 (03) : 130 - 135
  • [45] AIRWAY PRESSURE MEASUREMENT DURING HIGH-FREQUENCY JET VENTILATION
    HEARD, SO
    BANNER, MJ
    JAEGER, MJ
    CRITICAL CARE MEDICINE, 1984, 12 (03) : 262 - 262
  • [46] PRESSURE AND FLOW INHOMOGENEITY IN THE AIRWAY DURING HIGH-FREQUENCY VENTILATION
    BALASSY, Z
    INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1988, 5 (03): : 179 - 186
  • [47] TIDAL VOLUME AND AIRWAY PRESSURE ON HIGH-FREQUENCY JET VENTILATION
    CARLON, GC
    RAY, C
    GRIFFIN, J
    MIDOWNIK, S
    GROEGER, JS
    CRITICAL CARE MEDICINE, 1983, 11 (02) : 83 - 86
  • [48] AIRWAY PRESSURE-GRADIENT DURING HIGH-FREQUENCY VENTILATION
    SUTTON, JE
    GLASS, DD
    CRITICAL CARE MEDICINE, 1984, 12 (09) : 774 - 776
  • [49] HIGH-FREQUENCY JET VENTILATION IMPROVES GAS-EXCHANGE WHEN COMPARED TO HIGH-FREQUENCY OSCILLATORY VENTILATION AT EQUIVALENT AIRWAY PRESSURES
    BOROS, SJ
    MAMMEL, MC
    HORCHER, P
    GORDON, MJ
    PEDIATRIC RESEARCH, 1987, 21 (04) : A445 - A445
  • [50] HIGH-FREQUENCY JET VENTILATION IMPROVES GAS-EXCHANGE WHEN COMPARED TO HIGH-FREQUENCY OSCILLATORY VENTILATION AT EQUIVALENT AIRWAY PRESSURES
    BOROS, SJ
    MAMMEL, MC
    HORCHER, P
    GORDON, MJ
    BING, DR
    PEDIATRIC PULMONOLOGY, 1987, 3 (05) : 373 - 373