Correlation between Laser Fluorescence Readings and Volume of Tooth Preparation in Incipient Occlusal Caries In Vitro

被引:9
|
作者
Ghaname, Eduardo S. [2 ]
Ritter, Andre V. [1 ]
Heymann, Harald O.
Vann, William F., Jr. [3 ]
Shugars, Daniel A.
Bader, James D.
机构
[1] Univ N Carolina, Sch Dent, Dept Operat Dent, Chapel Hill, NC 27599 USA
[2] Univ Michigan, Dept Cariol Restorat Sci & Endodont, Ann Arbor, MI 48109 USA
[3] Univ N Carolina, Dept Pediat Dent, Chapel Hill, NC 27599 USA
关键词
LONGITUDINAL MICRORADIOGRAPHY; VISUAL INSPECTION; PERFORMANCE; DIAGNODENT; DIAGNOSIS; RELIABILITY; VALIDITY; LESIONS; TEETH; RADIOGRAPHY;
D O I
10.1111/j.1708-8240.2009.00309.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This study evaluated the correlation between laser fluorescence readings and the extent of incipient occlusal caries as measured by the volume of tooth preparation in vitro. Materials and Methods: One hundred and three permanent molars and premolars containing incipient occlusal pit-and-fissure caries and sound occlusal surfaces (1/4 of the sample, control) were selected. DIAGNOdent (KaVo Dental Corporation, Lake Zurich, IL, USA) readings were obtained according to manufacturer instructions. Caries was removed with 1/4 round burs in high speed. The volume of tooth preparation was measured using a surrogate measure based on the amount of composite needed to fill the preparations. Sensitivity and specificity using different cutoff values were calculated for lesions/preparations extending into dentin. The results were analyzed statistically. Results: The Pearson correlation for preparation volume and DIAGNOdent reading measurements was low (r = 0.285). Sensitivity and specificity of DIAGNOdent for detection of dentinal lesions were 0.83 and 0.60, and 0.66 and 0.73 for the cutoff values of 20 and 30, respectively. Conclusions: Within the limitations of this study, laser fluorescence measured with DIAGNOdent does not correlate well with extent of carious tooth structure in incipient occlusal caries. CLINICAL SIGNIFICANCE Clinicians should not rely only on DIAGNOdent readings to determine the extension of incipient occlusal caries. (J Esthet Restor Dent 22:31-41, 2010).
引用
收藏
页码:31 / 39
页数:9
相关论文
共 50 条
  • [31] Clinical performance of a laser fluorescence device for detection of occlusal caries lesions
    Lussi, A
    Megert, B
    Longbottom, C
    Reich, E
    Francescut, P
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2001, 109 (01) : 14 - 19
  • [32] Detection of occlusal caries under sealants by use of a laser fluorescence system
    Takamori, K
    Hokari, N
    Okumura, Y
    Watanabe, S
    JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 2001, 19 (05): : 267 - 271
  • [33] Comparison of two laser fluorescence devices for the detection of occlusal caries in vivo
    Krause, F.
    Jepsen, S.
    Braun, A.
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2007, 115 (04) : 252 - 256
  • [34] Laser fluorescence system for detection of occlusal caries in third molars.
    Baseren, NM
    Gökalp, S
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 475 - 475
  • [35] Occlusal caries detection: A comparison of a laser fluorescence system and conventional methods
    Burin, C
    Burin, C
    Loguercio, AD
    Grande, RHM
    Reis, A
    PEDIATRIC DENTISTRY, 2005, 27 (04) : 307 - 312
  • [36] Effect of placing a clear sealant on the validity and reproducibility of occlusal caries detection by a laser fluorescence device: An in vitro study
    Deery, C.
    Iloya, J.
    Nugent, Z. J.
    Srinivasan, V.
    CARIES RESEARCH, 2006, 40 (03) : 186 - 193
  • [37] Detection of occlusal caries with impedance spectroscopy and laser fluorescence before and after placement of fissure sealants: An in vitro study
    Mortensen, Diana
    Ekstrand, Kim Rud
    Twetman, Svante
    AMERICAN JOURNAL OF DENTISTRY, 2016, 29 (04): : 229 - 233
  • [38] Diagnostic comparison of three groups of examiners using visual and laser fluorescence methods to detect occlusal caries in vitro
    Fung, L
    Smales, R
    Ngo, H
    Mount, G
    AUSTRALIAN DENTAL JOURNAL, 2004, 49 (02) : 67 - 71
  • [39] The Effect of Distance and Tooth Structure on Laser Fluorescence Caries Detection
    Markowitz, K.
    Stenvall, R. M.
    Graye, M.
    OPERATIVE DENTISTRY, 2012, 37 (02) : 150 - 160
  • [40] In vitro validity of a laser-based device for occlusal caries detection
    Longbottom, C
    Ferrier, S
    Pitts, NB
    Deery, C
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1044 - 1044