Characterization of a 2D Array for QA and Pretreatment Plan Verification

被引:0
|
作者
Anvari, A.
Aghamiri, S.
Mahdavi, S.
Alaei, P.
机构
关键词
Dosimetry; Ionization chambers; Photons; Particle beam detectors; Ion beam detectors; Surface ionization; Data analysis; Computer software; Ion beam sources;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-E-T-65
引用
收藏
页码:237 / +
页数:2
相关论文
共 50 条
  • [1] Characterization of a 2D ionization chamber array for IMRT plan verification
    Alashrah, S.
    Kandaiya, S.
    Yong, S. Y.
    Cheng, S. K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3): : 181 - 185
  • [2] Portal dosimetry for pretreatment verification of IMRT plan: a comparison with 2D ion chamber array
    Sharma, Dayananda Shamurailatpam
    Mhatre, Vaibav
    Heigrujam, Malhotra
    Talapatra, Kaustav
    Mallik, Suman
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (04): : 238 - 248
  • [3] Characterization of a 2D ionization chamber array for IMRT QA
    Shtraus, N.
    Curran, B.
    Moran, J.
    Litzenberg, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2600 - 2600
  • [4] Evaluation of Hybrid Plan IMRT QA with a 2D Ionization Chamber Array
    Depuydt, T.
    Gomola, I.
    Van den Heuvel, F.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [5] STUDY OF 2D ION CHAMBER ARRAY RESPONSE AT ACTUAL TREATMENT ANGLE FOR PRETREATMENT IMRT PLAN VERIFICATION
    Bhardwaj, A.
    Janardhan, N.
    Kataria, T.
    Jagadeesan, S.
    Vikraman, S.
    Karrthick, P.
    Jassai, K.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S443 - S443
  • [6] IMRT plan verification using a 2D ion chamber array
    Spezi, E
    Angelini, AL
    Romani, F
    Ferri, A
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S176 - S177
  • [7] IMRT QA with a 2D diode array
    Ding, L
    Ahluwalia, W
    Liu, C
    Li, J
    Palta, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1396 - 1396
  • [8] Evaluation of a 2D diode array for IMRT QA
    Letourneau, D
    MEDICAL PHYSICS, 2003, 30 (06) : 1396 - 1396
  • [9] Dosimetric plan verification using a 2D ionization chamber array in helical IMRT
    Yango, A.
    Schoroth, F.
    Muedder, T.
    Poppe, B.
    Garbe, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 108 - 109
  • [10] Characterization of a 2D ion chamber array for the verification of radiotherapy treatments
    Spezi, E
    Angelini, AL
    Romani, F
    Ferri, A
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (14): : 3361 - 3373