Prevention of Posterior Capsule Opacification by an Intracapsular Open Capsule Device

被引:23
|
作者
Alon, Roy [1 ]
Assia, Ehud I. [1 ]
Kleinmann, Guy [2 ]
机构
[1] Meir Med Ctr, Dept Ophthalmol, Kefar Sava, Israel
[2] Kaplan Med Ctr, Dept Ophthalmol, IL-76100 Rehovot, Israel
关键词
posterior capsule; opacification; prevention; ACCOMMODATING INTRAOCULAR-LENS; EPITHELIAL-CELLS; BAG OPACIFICATION; RANDOMIZED-TRIAL; EQUATOR RINGS; BENDING RING; LONG-TERM; FOLLOW-UP; PART; IMPLANTATION;
D O I
10.1167/iovs.14-14364
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate the ability of an open capsule device to prevent posterior capsule opacification. METHODS. A total of 40 eyes of 20 New Zealand white rabbits were randomly divided into six similar groups of 6 to 7 eyes each. After crystalline lens evacuation, one control group (group A) was implanted with a hydrophilic acrylic intraocular lens and no device, and another control group (group B) was implanted with a hydrophobic acrylic intraocular lens and no device. The study groups were implanted with a hydrophilic acrylic intraocular lens and a hydrophilic acrylic device (group C), a hydrophobic acrylic intraocular lens and a hydrophilic acrylic device (group D), a hydrophilic acrylic intraocular lens and a hydrophobic acrylic device (group E), and a hydrophobic acrylic intraocular lens and a hydrophobic acrylic device (group F). The rabbits were monitored for the ensuing 6 weeks and then killed. The enucleated eyes were evaluated using the Miyake-Apple view, Matlab software analysis, and histology. RESULTS. The posterior capsule opacification score was significantly reduced in the eyes that were implanted with the tested device compared with the control eyes (clinical evaluation: 69% reduction, P = 0.001; the Miyake-Apple view analysis: 77% reduction, P = 0.000; histology: 75% reduction, P = 0.000). Soemmering's ring area was significantly reduced in the eyes implanted with the tested device compared with the control eyes (Matlab analysis: 80% reduction, P = 0.000). CONCLUSIONS. The tested devices were effective in reducing posterior capsule opacification and Soemmering's ring formation.
引用
收藏
页码:4005 / 4013
页数:9
相关论文
共 50 条
  • [31] Evaluation of laser capsule polishing for prevention of posterior capsule opacification in a human ex vivo model
    Luft, Nikolaus
    Kreutzer, Thomas C.
    Dirisamer, Martin
    Priglinger, Claudia S.
    Burger, Johannes
    Findl, Oliver
    Priglinger, Siegfried G.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (12): : 2739 - 2745
  • [32] Intracapsular ring sustained 5-fluorouracil delivery system for the prevention of posterior capsule opacification in rabbits - A histological study
    Pandey, SK
    Cochener, B
    Apple, DJ
    Colin, J
    Werner, L
    Bougaran, R
    Trivedi, RH
    Macky, TA
    Izak, AM
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (01): : 139 - 148
  • [33] In vitro lens capsule model for investigation of posterior capsule opacification
    Cleary, Georgia
    Spalton, David J.
    Zhang, Jin-Jun
    Marshall, John
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08): : 1249 - 1252
  • [34] Posterior capsule opacification in diabetic patients
    Prakash, Gaurav
    Jhanji, Vishal
    Sharma, Namrata
    Titiyal, Jeewan S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03): : 363 - 364
  • [35] Posterior capsule opacification in myopic eyes
    Hayashi, K
    Yoshida, M
    Hayashi, H
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (04): : 634 - 638
  • [36] Risk factors for posterior capsule opacification
    McLeod, SD
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (11) : 1389 - 1390
  • [37] Capsulorhexis size and posterior capsule opacification
    Ravalico, G
    Tognetto, D
    Palomba, M
    Busatto, P
    Baccara, F
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (01): : 98 - 103
  • [38] Methods of quantifying posterior capsule opacification
    Spalton, DJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07): : 1247 - 1247
  • [39] Posterior capsule opacification: back to basics
    Allen, David
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (06): : 509 - 510
  • [40] Development of posterior capsule opacification in the rabbit
    Wallentin, N
    Lundgren, B
    Holmén, JB
    Lundberg, C
    OPHTHALMIC RESEARCH, 2002, 34 (01) : 14 - 22