Diagnostic performance and image quality of low- tube voltage and low- contrast medium dose protocol with hybrid iterative reconstruction for hepatic dynamic CT

被引:10
|
作者
Ichikawa, Shintaro [1 ]
Motosugi, Utaroh [1 ,2 ]
Shimizu, Tatsuya [1 ]
Kromrey, Marie Luise [1 ,3 ]
Aikawa, Yoshihito [4 ]
Tamada, Daiki [1 ]
Onishi, Hiroshi [1 ]
机构
[1] Univ Yamanashi, Dept Radiol, Chuo Ku, 1110 Shimokato, Kofu, Yamanashi, Japan
[2] Kofu Kyoritsu Hosp, Dept Diagnost Radiol, 1-9-1 Takara, Kofu, Yamanashi, Japan
[3] Univ Med Greifswald, Dept Diagnost Radiol & Neuroradiol, Domstr 11, Greifswald, Germany
[4] Univ Yamanashi Hosp, Div Radiol, Chuo Ku, 1110 Shimokato, Kofu, Yamanashi, Japan
来源
BRITISH JOURNAL OF RADIOLOGY | 2021年 / 94卷 / 1128期
关键词
COMPUTED-TOMOGRAPHY; HEPATOCELLULAR-CARCINOMA; THIN ADULTS; 80; KVP; ALGORITHM; LIVER; REDUCTION; DETECTABILITY; LESIONS; RISK;
D O I
10.1259/bjr.20210601
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the diagnostic performance and image quality of the low tube voltage and low-contrast medium dose protocol for hepatic dynamic CT. Methods: This retrospective study was conducted between January and May 2018. All patients underwent hepatic dynamic CT using one of the two protocols: tube voltage, 80 kVp and contrast dose, 370 mgI/kg with hybrid iterative reconstruction or tube voltage, 120 kVp and contrast dose, 600 mgI/kg with filtered back projection. Two radiologists independently scored lesion conspicuity and image quality. Another radiologist measured the CT numbers of abdominal organs, muscles, and hepatocellular carcinoma (HCC) in each phase. Lesion detectability, HCC diagnostic ability, and image quality of the arterial phase were compared between the two protocols using the non-inferiority test. CT numbers and HCC- to- liver contrast were compared between the protocols using the Mann-Whitney U test. Results: 424 patients (70.5 +/- 10.1 years) were evaluated. The 80- kVp protocol showed non-inferiority in lesion detectability and diagnostic ability for HCC (sensitivity, 85.7-89.3%; specificity, 96.3-98.6%) compared with the 120- kVp protocol (sensitivity, 91.0-93.3%; specificity, 93.6-97.3%) (p < 0.001-0.038). The ratio of fair image quality in the 80- kVp protocol also showed non inferiority compared with that in the 120- kVp protocol in assessments by both readers (p < 0.001). HCC- to- liver contrast showed no significant differences for all phases (p = 0.309-0.705) between the two protocols. Conclusion: The 80- kVp protocol with hybrid iterative reconstruction for hepatic dynamic CT can decrease iodine doses while maintaining diagnostic performance and image quality compared with the 120- kVp protocol. Advances in knowledge: The 80-and 120- kVp protocols showed equivalent hepatic lesion detectability, diagnostic ability for HCC, image quality, and HCC- to- liver contrast. The 80- kVp protocol showed a 38.3% reduction in iodine dose compared with the 120- kVp protocol.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Diagnostic Performance in Low- and High- Contrast Tasks of an Image-Based Denoising Algorithm Applied to Radiation Dose Reduced Multiphase Abdominal CT Examinations
    Inoue, Akitoshi
    Voss, Benjamin A.
    Lee, Nam Ju
    Takahashi, Hiroaki
    Kozaka, Kazuto
    Heiken, Jay P.
    Ehman, Eric C.
    Vasconcelos, Rogerio
    Fidler, Jeff L.
    Lee, Yong S.
    Mileto, Achille
    Johnson, Matthew P.
    Baer-Beck, Matthias
    Weber, Nikkole M.
    Michalak, Gregory J.
    Halaweish, Ahmed
    Carter, Rickey E.
    McCollough, Cynthia H.
    Fletcher, Joel G.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 220 (01) : 73 - 85
  • [42] Adrenal and nephrogenic hypertension: an image quality study of low tube voltage, low-concentration contrast media combined with adaptive statistical iterative reconstruction
    Li, Zhen
    Li, Qiong
    Shen, Yaqi
    Li, Anqin
    Li, Haojie
    Liang, Lili
    Hu, Yao
    Hu, Xuemei
    Hu, Daoyu
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2016, 70 (9B) : B29 - B36
  • [43] Low-Contrast and Low-Radiation Dose Protocol in Cardiac Computed Tomography: Usefulness of Low Tube Voltage and Knowledge-Based Iterative Model Reconstruction Algorithm
    Iyama, Yuji
    Nakaura, Takeshi
    Yokoyama, Koichi
    Kidoh, Masafumi
    Harada, Kazunori
    Oda, Seitaro
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (06) : 941 - 947
  • [44] Image quality assessment of artificial intelligence iterative reconstruction for low dose unenhanced abdomen: comparison with hybrid iterative reconstruction
    Qi, Hui
    Cui, Dingye
    Xu, Shijie
    Li, Wei
    Zeng, Qingshi
    ABDOMINAL RADIOLOGY, 2024,
  • [45] Low Tube Voltage and Iterative Model Reconstruction in Follow-up CT Angiography After Thoracic Endovascular Aortic Repair: Ultra-low Radiation Exposure and Contrast Medium Dose
    Hou, Ping
    Feng, Xiangnan
    Liu, Jie
    Wang, Xiaopeng
    Jiang, Yaojun
    Dong, Leigang
    Gao, Jianbo
    ACADEMIC RADIOLOGY, 2018, 25 (04) : 494 - 501
  • [46] Hybrid Iterative Reconstruction Technique for Abdominal CT Protocols in Obese Patients: Assessment of Image Quality, Radiation Dose, and Low-Contrast Detectability in a Phantom
    Schindera, Sebastian T.
    Odedra, Devang
    Mercer, Diego
    Thipphavong, Seng
    Chou, Paul
    Szucs-Farkas, Zsolt
    Rogalla, Patrik
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (02) : W146 - W152
  • [47] Prospective ECG-triggering cardiac CT for infants with complex congenital heart disease using low-dose contrast medium, low tube voltage, and adaptive statistical iterative reconstruction
    Wang, S. -Y.
    Gao, W.
    Zhong, Y. -M.
    Sun, A. -M.
    Wang, Q.
    Hu, L. -W.
    Qiu, H. -S.
    Li, J. -Y.
    CLINICAL RADIOLOGY, 2017, 72 (06) : 502 - 507
  • [48] Image Quality and Patient-Specific Organ Doses in Stone Protocol CT: A Comparison of Traditional CT to Low Dose CT with Iterative Reconstruction
    Pai, Raghav
    Modh, Rishi
    Lamoureux, Rebecca H.
    Deitte, Lori
    Wymer, David C.
    Mench, Anna
    Lipnharski, Izabella
    Henriksen, Carl
    Arreola, Manuel
    Canales, Benjamin K.
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [49] Image quality evaluation of iterative model reconstruction on low tube voltage (80 kVp) coronary CT angiography in an animal study
    Hu, Mao-Qing
    Li, Meng
    Liu, Zai-Yi
    Huang, Mei-Ping
    Liu, Hui
    Liang, Chang-Hong
    ACTA RADIOLOGICA, 2016, 57 (02) : 170 - 177
  • [50] Image Quality and Diagnostic Performance of Low-Dose Liver CT with Deep Learning Reconstruction versus Standard-Dose CT
    Lee, Dong Ho
    Lee, Jeong Min
    Lee, Chang Hee
    Afat, Saif
    Othman, Ahmed
    RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2024, 6 (02)