Diagnostic performance and image quality of low- tube voltage and low- contrast medium dose protocol with hybrid iterative reconstruction for hepatic dynamic CT

被引:10
|
作者
Ichikawa, Shintaro [1 ]
Motosugi, Utaroh [1 ,2 ]
Shimizu, Tatsuya [1 ]
Kromrey, Marie Luise [1 ,3 ]
Aikawa, Yoshihito [4 ]
Tamada, Daiki [1 ]
Onishi, Hiroshi [1 ]
机构
[1] Univ Yamanashi, Dept Radiol, Chuo Ku, 1110 Shimokato, Kofu, Yamanashi, Japan
[2] Kofu Kyoritsu Hosp, Dept Diagnost Radiol, 1-9-1 Takara, Kofu, Yamanashi, Japan
[3] Univ Med Greifswald, Dept Diagnost Radiol & Neuroradiol, Domstr 11, Greifswald, Germany
[4] Univ Yamanashi Hosp, Div Radiol, Chuo Ku, 1110 Shimokato, Kofu, Yamanashi, Japan
来源
BRITISH JOURNAL OF RADIOLOGY | 2021年 / 94卷 / 1128期
关键词
COMPUTED-TOMOGRAPHY; HEPATOCELLULAR-CARCINOMA; THIN ADULTS; 80; KVP; ALGORITHM; LIVER; REDUCTION; DETECTABILITY; LESIONS; RISK;
D O I
10.1259/bjr.20210601
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the diagnostic performance and image quality of the low tube voltage and low-contrast medium dose protocol for hepatic dynamic CT. Methods: This retrospective study was conducted between January and May 2018. All patients underwent hepatic dynamic CT using one of the two protocols: tube voltage, 80 kVp and contrast dose, 370 mgI/kg with hybrid iterative reconstruction or tube voltage, 120 kVp and contrast dose, 600 mgI/kg with filtered back projection. Two radiologists independently scored lesion conspicuity and image quality. Another radiologist measured the CT numbers of abdominal organs, muscles, and hepatocellular carcinoma (HCC) in each phase. Lesion detectability, HCC diagnostic ability, and image quality of the arterial phase were compared between the two protocols using the non-inferiority test. CT numbers and HCC- to- liver contrast were compared between the protocols using the Mann-Whitney U test. Results: 424 patients (70.5 +/- 10.1 years) were evaluated. The 80- kVp protocol showed non-inferiority in lesion detectability and diagnostic ability for HCC (sensitivity, 85.7-89.3%; specificity, 96.3-98.6%) compared with the 120- kVp protocol (sensitivity, 91.0-93.3%; specificity, 93.6-97.3%) (p < 0.001-0.038). The ratio of fair image quality in the 80- kVp protocol also showed non inferiority compared with that in the 120- kVp protocol in assessments by both readers (p < 0.001). HCC- to- liver contrast showed no significant differences for all phases (p = 0.309-0.705) between the two protocols. Conclusion: The 80- kVp protocol with hybrid iterative reconstruction for hepatic dynamic CT can decrease iodine doses while maintaining diagnostic performance and image quality compared with the 120- kVp protocol. Advances in knowledge: The 80-and 120- kVp protocols showed equivalent hepatic lesion detectability, diagnostic ability for HCC, image quality, and HCC- to- liver contrast. The 80- kVp protocol showed a 38.3% reduction in iodine dose compared with the 120- kVp protocol.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Low Contrast Agent and Radiation Dose Protocol for Hepatic Dynamic CT of Thin Adults at 256-Detector Row CT: Effect of Low Tube Voltage and Hybrid Iterative Reconstruction Algorithm on Image Quality
    Nakaura, Takeshi
    Nakamura, Shinichi
    Maruyama, Natsuki
    Funama, Yoshinori
    Awai, Kazuo
    Harada, Kazunori
    Uemura, Shouzaburou
    Yamashita, Yasuyuki
    RADIOLOGY, 2012, 264 (02) : 445 - 454
  • [2] Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality
    Zhang, Xiuli
    Li, Shaodong
    Liu, Wenlou
    Huang, Ning
    Li, Jingjing
    Cheng, Li
    Xu, Kai
    MEDICINE, 2016, 95 (26)
  • [3] Impact of Knowledge-Based Iterative Model Reconstruction in Abdominal Dynamic CT With Low Tube Voltage and Low Contrast Dose
    Iyama, Yuji
    Nakaura, Takeshi
    Yokoyama, Koichi
    Kidoh, Masafumi
    Harada, Kazunori
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (04) : 687 - 693
  • [4] Improvement of Image Quality at Low-Radiation Dose and Low-Contrast Material Dose Abdominal CT in Patients With Cirrhosis: Intraindividual Comparison of Low Tube Voltage With Iterative Reconstruction Algorithm and Standard Tube Voltage
    Namimoto, Tomohiro
    Oda, Seitaro
    Utsunomiya, Daisuke
    Shimonobo, Toshiaki
    Morita, Sosuke
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (04) : 495 - 501
  • [5] Low contrast- and low radiation dose protocol for cardiac CT of thin adults at 256-row CT: usefulness of low tube voltage scans and the hybrid iterative reconstruction algorithm
    Nakaura, Takeshi
    Kidoh, Masafumi
    Sakaino, Naritsugu
    Utsunomiya, Daisuke
    Oda, Seitaro
    Kawahara, Tetsuya
    Harada, Kazunori
    Yamashita, Yasuyuki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (04): : 913 - 923
  • [6] Low contrast- and low radiation dose protocol for cardiac CT of thin adults at 256-row CT: usefulness of low tube voltage scans and the hybrid iterative reconstruction algorithm
    Takeshi Nakaura
    Masafumi Kidoh
    Naritsugu Sakaino
    Daisuke Utsunomiya
    Seitaro Oda
    Tetsuya Kawahara
    Kazunori Harada
    Yasuyuki Yamashita
    The International Journal of Cardiovascular Imaging, 2013, 29 : 913 - 923
  • [7] A Hybrid Iterative Reconstruction Algorithm That Improves the Image Quality of Low-Tube-Voltage Coronary CT Angiography
    Oda, Seitaro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Yonenaga, Kazuchika
    Namimoto, Tomohiro
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05) : 1126 - 1131
  • [8] The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography Effects on image quality and radiation dose
    Feng, Cui
    Zhu, Di
    Zou, Xianlun
    Li, Anqin
    Hu, Xuemei
    Li, Zhen
    Hu, Daoyu
    MEDICINE, 2018, 97 (12)
  • [9] Improving image quality with deep learning image reconstruction in double- low- dose head CT angiography compared with standard dose and adaptive statistical iterative reconstruction
    Huang, Xin
    Zhao, Wenzhe
    Wang, Geliang
    Wang, Yiming
    LI, Jianying
    LI, Yabshou
    Zeng, Qiang
    Guo, Jianxin
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1143):
  • [10] Image Quality Assessment of Low-Dose CT using Hybrid Iterative Reconstruction
    Zhang, Qiao
    Sheng, Jinhua
    Chen, Bin
    JOURNAL OF IMAGING SCIENCE AND TECHNOLOGY, 2021, 65 (06)