Evaluation of split-filter dual-energy CT for characterization of urinary stones

被引:4
|
作者
Appel, Elisabeth [1 ]
Thomas, Christoph [2 ]
Steuwe, Andrea [1 ]
Schaarschmidt, Benedikt M. [3 ]
Brook, Olga R. [4 ]
Aissa, Joel [5 ]
Hennenlotter, Joerg [6 ]
Antoch, Gerald [1 ]
Boos, Johannes [7 ]
机构
[1] Univ Dusseldorf, Fac Med, Dept Diagnost & Intervent Radiol, Moorenstr 5, D--40225 Dusseldorf, Germany
[2] Radiol Krefeld, Oberdiessemer Str 96, D-47805 Krefeld, Germany
[3] Univ Duisburg Essen, Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, D--45147 Essen, Germany
[4] Harvard Med Sch, Dept Radiol, Beth Israel Deaconess Med Ctr, 330 Brookline Ave, Boston, MA 02115 USA
[5] RIO Radiol Inst Oberhausen, Mulheimer Str 87, D-46045 Oberhausen, Germany
[6] Univ Hosp Tubingen, Dept Urol, Tubingen, Germany
[7] Radiol Munster MVZ, Von Steuben Str 10a, D-48143 Munster, Germany
来源
BRITISH JOURNAL OF RADIOLOGY | 2021年 / 94卷 / 1127期
关键词
URIC-ACID; COMPUTED-TOMOGRAPHY; RENAL STONES; DIFFERENTIATION; CALCULI; DISEASE;
D O I
10.1259/bjr.20210084
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To assess accuracy of dual-energy computed tomography (DECT) to differentiate uric acid from calcium urinary stones in dual-energy split filter vs sequential-spiral vs dual-source acquisition. Methods: Thirty four urinary stones (volume 89.0 +/- 77.4 mm(3); 17 calcium stones, 17 uric acid stones) were scanned in a water-filled phantom using a split-filter equipped CT scanner (SOMATOM Definition Edge, Siemens Healthineers, Forchheim, Germany) in split filter mode at 120 kVp and sequential-spiral mode at 80 and 140 kVp. Additional DE scans were acquired at 80 and 140 kVp (tin filter) with a dual-source CT scanner (SOMATOM Definition FLASH, Siemens Healthineers). Scans were performed with a CTDIvol of 7.3 mGy in all protocols. Urinary stone categorization was based on dual energy ratio (DER) using an automated 3D segmentation. As reference standard, infrared spectroscopy was used to determine urinary stone composition. Results: All three DECT techniques significantly differentiated between uric acid and calcium stones by attenuation values and DERs (p < 0.001 for all). Split-filter DECT provided higher DERs for uric acid stones, when compared with dual-source and sequential-spiral DECT, and lower DERs for calcified stones when compared with dual-source DECT (p < 0.001 for both), leading to a decreased accuracy for material differentiation. Conclusion: Split-filter DECT, sequential-spiral DECT and dual-source DECT all allow for the acquisition of DER to classify urinary stones. Advances in knowledge: Split-filter DECT enables the differentiation between uric acid and calcium stones despite decreased spectral separation when compared with dual-source and dual-spiral DECT.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Metal implants on abdominal CT: does split-filter dual-energy CT provide additional value over iterative metal artifact reduction?
    Hildegard M. Wichtmann
    Kai R. Laukamp
    Sebastian Manneck
    Konrad Appelt
    Bram Stieltjes
    Daniel T. Boll
    Matthias R. Benz
    Markus M. Obmann
    Abdominal Radiology, 2023, 48 : 424 - 435
  • [22] Split-bolus dual-energy CT urography: protocol optimization and diagnostic performance for the detection of urinary stones
    Christoph A. Karlo
    Ralph Gnannt
    Anna Winklehner
    Michael A. Fischer
    Olivio F. Donati
    Daniel Eberli
    Tullio Sulser
    Hatem Alkadhi
    Paul Stolzmann
    Abdominal Imaging, 2013, 38 : 1136 - 1143
  • [23] Split-bolus dual-energy CT urography: protocol optimization and diagnostic performance for the detection of urinary stones
    Karlo, Christoph A.
    Gnannt, Ralph
    Winklehner, Anna
    Fischer, Michael A.
    Donati, Olivio F.
    Eberli, Daniel
    Sulser, Tullio
    Alkadhi, Hatem
    Stolzmann, Paul
    ABDOMINAL IMAGING, 2013, 38 (05): : 1136 - 1143
  • [24] Contrast Enhancement in Primary Oropharyngeal Tumors Through the Use of Split-Filter Dual Energy CT
    Lawless, M.
    Harari, P.
    Burr, A.
    Kimple, R.
    Shah, J.
    Miller, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [25] Differentiation of Kidney Stones Using Dual-Energy CT With and Without a Tin Filter
    Fung, George S. K.
    Kawamoto, Satomi
    Matlaga, Brian R.
    Taguchi, Katsuyuki
    Zhou, Xiaodong
    Fishman, Elliot K.
    Tsui, Benjamin M. W.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (06) : 1380 - 1386
  • [26] Combination of Iterative Metal Artifact Reduction and Virtual Monoenergetic Reconstruction Using Split-Filter Dual-Energy CT in Patients With Dental Artifact on Head and Neck CT
    Schmidt, Alexander Marcel Alfred
    Grunz, Jan-Peter
    Petritsch, Bernhard
    Gruschwitz, Philipp
    Knarr, Jonas
    Huflage, Henner
    Bley, Thorsten Alexander
    Kosmala, Aleksander
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (04) : 716 - 727
  • [27] Comparison of image quality between split-filter twin beam dual energy and single energy images in abdominal CT
    Niu, Zhongfeng
    Chen, Jiao
    Ren, Hong
    Wang, Yang
    Tao, XinWei
    Zhan, Kun
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 121
  • [28] Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT
    Euler, Andre
    Obmann, Markus M.
    Szucs-Farkas, Zsolt
    Mileto, Achille
    Zaehringer, Caroline
    Falkowski, Anna L.
    Winkel, David J.
    Marin, Daniele
    Stieltjes, Bram
    Krauss, Bernhard
    Schindera, Sebastian T.
    EUROPEAN RADIOLOGY, 2018, 28 (08) : 3405 - 3412
  • [29] Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT
    André Euler
    Markus M. Obmann
    Zsolt Szucs-Farkas
    Achille Mileto
    Caroline Zaehringer
    Anna L. Falkowski
    David J. Winkel
    Daniele Marin
    Bram Stieltjes
    Bernhard Krauss
    Sebastian T. Schindera
    European Radiology, 2018, 28 : 3405 - 3412
  • [30] Dual-energy CT of the urinary tract
    Kaza, Ravi K.
    Platt, Joel F.
    Megibow, Alec J.
    ABDOMINAL IMAGING, 2013, 38 (01): : 167 - 179