Importance of long-term ground-loop temperature variation in performance optimization of Ground Source Heat Pump system

被引:18
|
作者
Cai, Wanlong [1 ,2 ]
Wang, Fenghao [1 ]
Chen, Shuang [2 ,3 ]
Chen, Chaofan [2 ,3 ]
Zhang, Yuping [4 ]
Kolditz, Olaf [2 ,3 ]
Shao, Haibing [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian 710049, Shaanxi, Peoples R China
[2] UFZ Helmholtz Ctr Environm Res, Permoserstr 15, D-04318 Leipzig, Germany
[3] Tech Univ Dresden, Fac Environm Sci, Dresden, Germany
[4] Minist Nat Resources, Key Lab Coal Resources Explorat & Comprehens Util, Xian 710021, Shaanxi, Peoples R China
关键词
Shallow geothermal energy utilization; Borehole heat exchanger array; Ground-loop temperature; Soil thermal balance; System optimization; GSHP; FEASIBILITY; EFFICIENCY; ENERGY;
D O I
10.1016/j.applthermaleng.2021.117945
中图分类号
O414.1 [热力学];
学科分类号
摘要
In a recent article published in this journal, a series of design optimization was executed for a ground source heat pump system. The optimization was conducted based on a COPall index, which considers both the hydraulic loss on the buried pipe network, as well as the soil thermal balance over a one-year period. In that article, it was concluded that a borehole spacing of 4m is the optimal value. In this short communication, the comprehensive COPall index is re-evaluated with the same system setup with both the TRNSYS and OpenGeoSys-TESPy software, but over a 20-year period. The results show that the borehole heat exchanger array with a spacing of 4m will suffer severe heat accumulation over a 20-year operation. This causes the soil temperature to rise by 5.68 degrees C, along with a decrease of COPall from 4.59 to 4.18. Due to the smaller increase of ground-loop temperature and lower electricity consumption from heat pumps, a larger spacing of 6m will bring better COPall value over the long term, and thus should be recommended. The extended numerical study in this work suggests that when evaluating the performance of a ground source heat pump system, different time duration will lead to different results. Therefore, the variation of long-term ground-loop temperature needs to be quantitatively evaluated in advance, and the system optimization is recommended to be conducted over the entire life cycle of the system.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Alternative refrigerants for the heat pump of a ground source heat pump system
    Sagia, Zoi
    Rakopoulos, Constantinos
    APPLIED THERMAL ENGINEERING, 2016, 100 : 768 - 774
  • [42] Evaluating Long-Term Performance of a Residential Ground-Source Heat Pump System under Climate Change in Cold and Warm Cities of Japan
    Sakata, Yoshitaka
    Akeyama, Yuma
    Katsura, Takao
    Nagano, Katsunori
    ENERGIES, 2023, 16 (06)
  • [43] Heat source performance for solar-ground source heat pump
    Bi, Y
    Chen, L
    Wu, C
    JOURNAL OF THE ENERGY INSTITUTE, 2005, 78 (04) : 185 - 189
  • [44] Optimization of thermal performance of a building with ground coupled heat pump system
    Zogou, Olympia
    Stamatelos, Anastassios
    ECOS 2006: PROCEEDINGS OF THE 19TH INTERNATIONAL CONFERENCE ON EFFICIENCY, COST, OPTIMIZATION, SIMULATION AND ENVIRONMENTAL IMPACT OF ENERGY SYSTEMS, VOLS 1-3, 2006, : 833 - +
  • [45] Identification, Implementation and Simulation of Ground Source Heat Pump with Ground Temperature Modeling
    Kose, Ahmet
    Petlenkov, Eduard
    2016 15TH BIENNIAL BALTIC ELECTRONICS CONFERENCE (BEC), 2016, : 163 - 166
  • [46] Design strategy and techno-economic optimization for hybrid ground heat exchangers of ground source heat pump system
    Zhou, Kun
    Mao, Jinfeng
    Zhang, Hua
    Li, Yong
    Yu, Xiaojun
    Chen, Fei
    Li, Min
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 52
  • [47] System Identification Models and Using Neural Networks for Ground Source Heat Pump with Ground Temperature Modeling
    Kose, Ahmet
    Petlenkov, Eduard
    2016 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2016, : 2850 - 2855
  • [48] Optimization of ground heat exchanger of the ground source heat pump system based on exergetic analysis using Taguchi technique
    Ahmad, Saif Nawaz
    Prakash, Om
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2021, 235 (21) : 5892 - 5901
  • [49] Study on Operation Optimization Strategy of Ground Source Heat Pump Heating System
    Chen, Cheng
    Chen, Xingying
    Yu, Kun
    Gan, Lei
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [50] COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM
    Zhu, Jiang
    Tao, Yong
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 4, PTS A AND B, 2012, : 693 - 699