The 1995 look-up table for critical heat flux in tubes

被引:210
|
作者
Groeneveld, DC
Leung, LKH
Kirillov, PL
Bobkov, VP
Smogalev, IP
Vinogradov, VN
Huang, XC
Royer, E
机构
[1] INST PHYS & POWER ENGN,OBNINSK,RUSSIA
[2] UNIV OTTAWA,DEPT MECH ENGN,OTTAWA,ON,CANADA
[3] ELECT FRANCE,DIRECT ETUD & RECH,CLAMART,FRANCE
关键词
D O I
10.1016/0029-5493(95)01154-4
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An updated version of the look-up table for critical heat flux (CHF) has been developed jointly by AECL Research (Canada) and IPPE (Obninsk, Russia). It is based on an extensive data base of CHF values obtained in tubes with a vertical upward flow of steam-water mixture. While the data base covers a wide range of flow conditions, the look-up table is designed to provide CHF values for 8 mm tubes at discrete values of pressure, mass flux and dryout quality covering the ranges 0.1 to 20.0 MPa, 0.0 to 8.0 Mg m(-2) s(-1) and -0.5 to +1.0 respectively. Linear interpolation is used to determine the CHF for conditions between the tabulated values, and an empirical correction factor is introduced to extend this CHF table to tubes of diameter values other than 8 mm. Compared against the combined AECL-IPPE world data bank (consisting of 22 946 data points after excluding duplicate data and obviously erroneous data), the 1995 look-up table predicts the data with overall average and root-mean-square errors of 0.69% and 7.82% respectively. An assessment of various CHF tables and several empirical correlations shows that the 1995 table consistently provides the best prediction accuracy and is applicable to the widest range of conditions.
引用
收藏
页码:1 / 23
页数:23
相关论文
共 50 条
  • [1] 1995 Look-up Table for Calculating Critical Heat Flux in Tubes
    State Sci. Ctr. of the Russ. Fed., Energy Physics Institute , pl. Bondarenko 1, Obninsk, Kaluzhskaya oblast, 249020, Russia
    不详
    不详
    不详
    Therm Eng, 10 (823-840):
  • [2] Addendum and Comments to the Paper 1995 Look-up Table for Calculating Critical Heat Flux in Tubes
    Kirillov, P.L.
    1997, IAPC Nauka/Interperiodica (44)
  • [3] Application of the Critical Heat Flux Look-Up Table to Large Diameter Tubes
    El Nakla, M.
    Habib, M.
    Ahmed, W.
    Al-Sarkhi, A.
    Ben Mansour, R.
    Al-Awwad, M. Y.
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2013, 2013
  • [4] Letter to the editor on the paper by D.C. Groeneveld and L.K.H. Leung, The 1995 look-up table for critical heat flux in tubes
    Todreas, N.E.
    Hejzlar, P.
    Nuclear Engineering and Design, 1996, 163 (1-2): : 25 - 26
  • [5] A look-up table for trans-critical heat transfer in water-cooled tubes
    Zahlan, H.
    Tavoularis, S.
    Groeneveld, D. C.
    NUCLEAR ENGINEERING AND DESIGN, 2015, 285 : 109 - 125
  • [6] Supercritical water heat transfer in vertical tubes: A look-up table
    Loewenberg, Matthias F.
    Laurien, Eckart
    Class, Andreas
    Schulenberg, Thomas
    PROGRESS IN NUCLEAR ENERGY, 2008, 50 (2-6) : 532 - 538
  • [7] The 1995 CHF look-up table - Reply
    Groenveld, DC
    NUCLEAR ENGINEERING AND DESIGN, 1996, 163 (1-2) : 27 - 28
  • [8] Improvement of the look-up tables for calculating the critical heat flux
    Gotovskii, M.A.
    Kvetnyi, M.A.
    Thermal Engineering (English translation of Teploenergetika), 2002, 49 (03): : 185 - 190
  • [9] Improvement of the look-up tables for calculating the critical heat flux
    Gotovskij, M.A.
    Kvetnyj, M.A.
    Teploenergetika, 2002, (03): : 11 - 16
  • [10] TABLE LOOK-UP RULE
    HARALICK, RM
    COMMUNICATIONS IN STATISTICS PART A-THEORY AND METHODS, 1976, 5 (12): : 1163 - 1191