A phantom study of the geometric accuracy of computed tomographic and magnetic resonance imaging stereotactic localization with the Leksell stereotactic system - Comment

被引:0
|
作者
Roberts, DW
机构
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
引用
收藏
页码:1099 / 1099
页数:1
相关论文
共 50 条
  • [31] Stereotactic Body Radiotherapy for Prostate Cancer with Magnetic Resonance Imaging or Computed Tomography Guidance
    Chang, E.
    Choi, S.
    Fnu, R. Z.
    Tang, C.
    Hassanzadeh, C. J.
    Mohamad, O.
    Frank, S. J.
    Shah, S. J.
    Mok, H.
    Kudchadker, R.
    Du, W.
    Wang, J.
    Yang, J.
    Mayo, L. L.
    Chronowski, G. M.
    Hoffman, K. E.
    McGuire, S. E.
    Kuban, D. A.
    Nguyen, Q. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E518 - E519
  • [32] Accuracy of magnetic resonance imaging stereotactic coordinates with the Cosman-Roberts-Wells frame
    Carter, DA
    Parsai, EI
    Ayyangar, KM
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1999, 72 (01) : 35 - 46
  • [33] Increased Frameless Stereotactic Accuracy With High-Field Intraoperative Magnetic Resonance Imaging
    Tanaka, Shota
    Puffer, Ross C.
    Hoover, Jason M.
    Goerss, Stephan J.
    Haugen, Laura M.
    McGee, Kiaran
    Parney, Ian F.
    NEUROSURGERY, 2012, 71 : 321 - 327
  • [34] Immobilization and Geometric Distortion Study for Magnetic Resonance Imaging Guided Stereotactic Radiosurgery On the ViewRay MR-Linac
    Omari, E.
    Hugo, G.
    Green, O.
    Mutic, S.
    Gach, H.
    Knutson, N.
    Reynoso, F.
    MEDICAL PHYSICS, 2018, 45 (06) : E548 - E548
  • [35] Magnetic resonance imaging-based stereotactic localization of the globus pallidus and subthalamic nucleus
    Starr, PA
    Vitek, JL
    DeLong, M
    Bakay, RAE
    NEUROSURGERY, 1999, 44 (02) : 303 - 313
  • [36] Magnetic resonance imaging stereotactic target localization for deep brain stimulation in dystonic children
    Vayssiere, N
    Hemm, S
    Zanca, M
    Picot, MC
    Bonafe, A
    Cif, L
    Frerebeau, P
    Coubes, P
    JOURNAL OF NEUROSURGERY, 2000, 93 (05) : 784 - 790
  • [37] An Optimized System for Interventional Magnetic Resonance Imaging-Guided Stereotactic Surgery: Preliminary Evaluation of Targeting Accuracy
    Larson, Paul S.
    Starr, Philip A.
    Bates, Geoffrey
    Tansey, Lisa
    Richardson, R. Mark
    Martin, Alastair J.
    NEUROSURGERY, 2012, 70
  • [38] Geometric accuracy of 3D coordinates of the Leksell stereotactic skull frame in 1.5 Tesla- and 3.0 Tesla-magnetic resonance imaging: a comparison of three different fixation screw materials
    Nakazawa, Hisato
    Mori, Yoshimasa
    Yamamuro, Osamu
    Komori, Masataka
    Shibamoto, Yuta
    Uchiyama, Yukio
    Tsugawa, Takahiko
    Hagiwara, Masahiro
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (06) : 1184 - 1191
  • [39] Does new magnetic resonance imaging technology provide better geometrical accuracy during stereotactic imaging?
    Novotny, J
    Vymazal, J
    Novotny, J
    Tlachacova, D
    Schmitt, M
    Chuda, P
    Urgosik, D
    Liscak, R
    JOURNAL OF NEUROSURGERY, 2005, 102 : 8 - 13
  • [40] Accuracy evaluation of real-time body surface imaging guided system in spinal stereotactic radiosurgery: a phantom study
    Park, Jeong-Mee
    Lee, Haenghwa
    Sohn, Moon-Jun
    Kim, Kwang Hyeon
    Koo, Hae-Won
    Yoon, Sang-Won
    Moon, Chi-Woong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2022, 81 (01) : 68 - 75