Repeatability of Open-MOLLI: An open-source inversion recovery myocardial T1 mapping sequence for fast prototyping

被引:1
|
作者
Gaspar, Andreia S. [1 ,2 ,6 ,7 ]
Silva, Nuno A. [3 ]
Ferreira, Antonio M. [4 ,5 ]
Nunes, Rita G. [1 ,2 ]
机构
[1] Univ Lisbon, Inst Sistemas & Robot Lisboa, Lisbon, Portugal
[2] Univ Lisbon, Dept Bioengn, Inst Super Tecn, Lisbon, Portugal
[3] Luz Saude, Hosp Luz Learning Hlth, Lisbon, Portugal
[4] Ctr Hosp Lisboa Ocidental, Hosp Santa Cruz, Serv Cardiol, Lisbon, Portugal
[5] Hosp Luz, Unidade Imagiol Cardiaca Avancada, Lisbon, Portugal
[6] Univ Lisbon, Inst Sistemas & Robot Lisboa, P-1049001 Lisbon, Portugal
[7] Univ Lisbon, Dept Bioengn, Inst Super Tecn, P-1049001 Lisbon, Portugal
关键词
cardiac MRI; open-source; Pulseq; repeatability; T1; mapping; PULSE SEQUENCE; REPRODUCIBILITY; ACCURACY; VALUES;
D O I
10.1002/mrm.30080
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop an open-source prototype of myocardial T1 mapping (Open-MOLLI) to improve accessibility to cardiac T1 mapping and evaluate its repeatability. With Open-MOLLI, we aim to enable faster implementation and testing of sequence modifications and to facilitate inter-scanner and cross-vendor reproducibility studies. Methods: Open-MOLLI is an inversion-recovery sequence using a balanced SSFP (bSSFP) readout, with inversion and triggering schemes based on the 5(3)3 MOLLI sequence, developed in Pulseq. Open-MOLLI and MOLLI sequences were acquired in the ISMRM/NIST phantom and 21 healthy volunteers. In 18 of those subjects, Open-MOLLI and MOLLI were repeated in the same session (test-retest). Results: Phantom T1 values were comparable between methods, specifically for the vial with reference T1 value most similar to healthy myocardium T1 (T1(vial3) = 1027 ms): T1(MOLLI) = 1011 +/- 24 ms versus T1(Open-MOLLI) = 1009 +/- 20 ms. In vivo T1 estimates were similar between Open-MOLLI and MOLLI (T1(MOLLI) = 1004 +/- 33 ms vs. T1(Open-MOLLI) = 998 +/- 52 ms), with a mean difference of -17 ms (p = 0.20), despite noisier Open-MOLLI weighted images and maps. Repeatability measures were slightly higher for Open-MOLLI (RCMOLLI = 3.0% vs. RCOpen-MOLLI = 4.4%). Conclusion: The open-source sequence Open-MOLLI can be used for T1 mapping in vivo with similar mean T1 values to the MOLLI method. Open-MOLLI increases the accessibility to cardiac T1 mapping, providing also a base sequence to which further improvements can easily be added and tested.
引用
收藏
页码:741 / 750
页数:10
相关论文
共 50 条
  • [1] Fast calculation software for modified Look-Locker inversion recovery (MOLLI) T1 mapping
    Kim, Yoon-Chul
    Kim, Khu Rai
    Lee, Hyelee
    Choe, Yeon Hyeon
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [2] Fast calculation software for modified Look-Locker inversion recovery (MOLLI) T1 mapping
    Yoon-Chul Kim
    Khu Rai Kim
    Hyelee Lee
    Yeon Hyeon Choe
    BMC Medical Imaging, 21
  • [3] Fast, precise, and accurate myocardial T1 mapping using a radial MOLLI sequence with FLASH readout
    Marty, B.
    Coppa, B.
    Carlier, P. G.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1387 - 1398
  • [4] Fast myocardial T1 mapping using shortened inversion recovery based schemes
    Huang, Li
    Neji, Radhouene
    Nazir, Muhummad Sohaib
    Whitaker, John
    Reid, Fiona
    Bosio, Filippo
    Chiribiri, Amedeo
    Razavi, Reza
    Roujol, Sebastien
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (02) : 641 - 654
  • [5] Validation of the shortened modified look locker inversion recovery (Sh-MOLLI) sequence for cardiac gated T1 mapping
    Piechnik S.K.
    Ferreira V.M.
    Dall'Armellina E.
    Neubauer S.
    Robson M.D.
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [6] Accuracy, Precision, and Reproducibility of Myocardial T1 Mapping: A Comparison of Four T1 Estimation Algorithms for Modified Look-Locker Inversion Recovery (MOLLI)
    Shao, Jiaxin
    Liu, Dapeng
    Sung, Kyunghyun
    Kim-Lien Nguyen
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1746 - 1756
  • [7] A segmented modified look-locker inversion recovery (MOLLI) sequence for high heart rate T1 mapping of mice
    Maryam Nezafat
    Markus Henningsson
    Christian Stehning
    Mehmet Akcakaya
    Andrea Protti
    Rene Botnar
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [8] Myocardial iron quantification using modified Look-Locker inversion recovery (MOLLI) T1 mapping at 3 Tesla
    GC Camargo
    T Rothstein
    FP Junqueira
    E Fernandes
    RL Lima
    A Greiser
    R Strecker
    JA Lima
    SS Xavier
    I Gottlieb
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [9] Effects of heart rate in modified look-locker inversion recovery (MOLLI) T1 mapping
    Yoshinori Suizuki
    Kunihiko Teraoka
    Yoshiaki Komori
    Andreas Greiser
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [10] Free-breathing MOLLI: Application to myocardial T1 mapping
    Tsai, Jyun-Ming
    Huang, Teng-Yi
    Tseng, Yu-Shen
    Lin, Yi-Ru
    MEDICAL PHYSICS, 2012, 39 (12) : 7291 - 7302