DC fault detection in hybrid MTDC systems using transient average of DC reactor voltage

被引:1
|
作者
Li, Jiapeng [1 ,2 ]
Li, Yujun [1 ,2 ]
Wang, Minghao [2 ]
Xu, Zhao [2 ]
Song, Guobing [1 ]
机构
[1] Xi An Jiao Tong Univ, 28 Xianning West Rd, Xian 710049, Peoples R China
[2] Hong Kong Polytech Univ, Kowloon, 11 Yuk Choi Rd, Hong Kong 999077, Peoples R China
关键词
Short-circuit current calculation; Hybrid MTDC system; Fault detection; Transient average voltage; SHORT-CIRCUIT; LCC-HVDC; PROTECTION; MODELS;
D O I
10.1016/j.ijepes.2023.109093
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The existence of various types of converters makes the fault characteristics of the hybrid multi-terminal DC (MTDC) system more complicated than the voltage source converter-based (VSC-based) MTDC system. A reduced line commutated converter (LCC) model for DC fault analysis is first proposed in this paper, where the LCC-based rectifier with control effects is regarded as an equivalent RLC circuit. By neglecting the resistive and capacitive components in the high-frequency domain, the original network analysis is significantly simplified to derive concise time-domain expressions of the initial DC fault current. On top of this, a single-terminal DC fault detection scheme using the transient average of DC reactor voltage is designed for the hybrid MTDC system. The thresholds for detecting faults on the LCC-connected and VSC-connected lines are calculated based on the derived fault current expressions, respectively. Simulation studies based on PSCAD/EMTDC have validated the proposed fault analysis model is accurate within the initial period after fault, while the proposed fault detection scheme for hybrid MTDC systems is fast, sensitive, and tolerant to high fault resistances.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] DC line current in a compact MTDC system for DC short-circuit fault analysis
    Fuentes-Burruel, Juan M. S.
    Moreno-Goytia, Edgar L.
    2022 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2022,
  • [42] The effects of different DC control on probabilistic transient stability of hybrid AC/DC systems
    Ding, M
    Wu, HB
    Huang, K
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 985 - 988
  • [43] A novel fault detection algorithm for high voltage DC networks
    Damian, Mihaela
    Damian, Ioan Catalin
    Iantoc, Andreea
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 157
  • [44] A Hybrid Bidirectional DC-DC Converter for Dual-Voltage Automotive Systems
    Li, Shouxiang
    Smedley, Keyue Ma
    Caldas, Diego Reis
    Martins, Yan Watanabe
    2017 THIRTY SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2017, : 355 - 361
  • [45] DC Arc-Fault Detection in PV Systems Using Multistage Morphological Fault Detection Algorithm
    Kavi, Moses
    Mishra, Yateendra
    Vilathgamuwa, Mahinda
    IECON 2018 - 44TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2018, : 1746 - 1751
  • [46] A Transient Voltage-Based DC Fault Line Protection Scheme for MMC-Based DC Grid Embedding DC Breakers
    Xiang, Wang
    Yang, Saizhao
    Xu, Lie
    Zhang, Junjie
    Lin, Weixing
    Wen, Jinyu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (01) : 334 - 345
  • [47] DC Voltage Target Predetermined Control of Hybrid MMC to Handle Line Fault of Overhead DC Grid
    Zhou M.
    Xiang W.
    Zuo W.
    Wen J.
    Lin W.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (17): : 5015 - 5024
  • [48] Impact of DC Line Voltage Drops on Power Flow of MTDC Using Droop Control
    Haileselassie, Temesgen M.
    Uhlen, Kjetil
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2012, 27 (03) : 1441 - 1449
  • [49] Cascaded commutation circuit for a hybrid DC breaker with dynamic control on fault current and DC breaker voltage
    Shan, Yunhai
    Lim, Tee C.
    Finney, Stephen J.
    Guang, Weixiao
    Williams, Barry W.
    Holliday, Derrick
    Ding, Xiao
    IET POWER ELECTRONICS, 2017, 10 (06) : 676 - 686
  • [50] Fault Detection of the Medium-Voltage DC Cable by Using the Featured Modal Signals
    Peng, Nan
    Xu, Lihua
    Liang, Rui
    Zhou, Guangyang
    Zhang, Peng
    Jin, Mohan
    Hou, Meng
    Li, Jian
    Pan, Yihang
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2024, 20 (08) : 10473 - 10487