Preliminary study of cine-MRI compression in MR-guided radiotherapy

被引:0
|
作者
Shang, Jiawen [1 ]
Huang, Peng [1 ]
Zhang, Ke [1 ]
Hu, Zhihui [1 ]
Yan, Hui [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Canc Hosp, Natl Clin Res Ctr Canc, Dept Radiat Oncol,Natl Canc Ctr, Beijing 100021, Peoples R China
基金
中国国家自然科学基金;
关键词
Cine-magnetic resonance imaging (cine-MRI); magnetic resonance-guided radiotherapy (MR-guided radiotherapy); data storage; compression; video encoder; IMAGE COMPRESSION; RADIATION-THERAPY; EXPERIENCE;
D O I
10.21037/qims-23-690
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Cine-magnetic resonance imaging (MRI) is currently used in real-time tumor tracking during magnetic resonance (MR)-guided radiotherapy. As a type of MRI specified for motion tracking, a few minutes' acquisition results in thousands of 2-dimensional (2D) images. For MR-guided radiotherapy consisting of multiple treatment fractions, the large number of cine-MRI images would be disproportionate to the tight clinical data storage available. To alleviate this issue, the feasibility of compression of cine-MRI via video encoders was investigated in this study. Methods: The cine-MRI images were first sorted into 3 sequences according to their plane orientations. Then, each sequence was reordered according to their acquisition times [time-based (TB)] or content similarities [similarity-based (SB)]. As a result, 3 sequences were obtained for 3 plan orientations. Next, the obtained sequences were processed by a video encoder and the corresponding 3 video files were achieved. We employed 3 popular video encoders: Motion JPEG (M-JPEG), Advanced Video Coding (AVC), and High Efficiency Video Coding (HEVC). The performances of the sequence reordering methods and video encoders were evaluated based on a total of 150 image sets. Results: The mean correlation quantities for SB sequences were higher than those for TB sequences by 3% (sagittal), 2% (coronal), and 1% (transverse), respectively. The average compression ratio (CR) yielded by the SB sequences was higher than that achieved by the TB sequences. Comparing with M-JPEG, the CRs obtained by AVC and HEVC were increased by 58% and 62% (sagittal), 16% and 23% (coronal), and 48% and 56% (transverse), respectively. Among the 3 video encoders, the highest CRs and restoration accuracy were achieved by HEVC. Conclusions: HEVC with inter-frame coding is more effective in reducing the redundant information in consecutive images. It is feasible to implement the video encoder for high-performance cine-MRI compression.
引用
收藏
页码:8009 / +
页数:12
相关论文
共 50 条
  • [21] Review of MR-Guided Radiotherapy for Esophageal Cancer
    Lee, Sangjune Laurence
    Bassetti, Michael
    Meijer, Gert J.
    Mook, Stella
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [22] Reference Dosimetry in External MR-Guided Radiotherapy
    Sarfehnia, A.
    Alvarez, P.
    Bouchard, H.
    de Prez, L.
    Dolan, J.
    Ibbott, G.
    Malkov, V.
    Muir, B.
    Rogers, D.
    Van Asselen, B.
    Wolthaus, J.
    Yadav, P.
    MEDICAL PHYSICS, 2022, 49 (06) : E208 - E209
  • [23] Implementation of MR-guided radiotherapy to treat oligometastases
    Saxby, H.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S372 - S372
  • [24] MR-Guided Adaptive Radiotherapy for Bladder Cancer
    Hijab, Adham
    Tocco, Boris
    Hanson, Ian
    Meijer, Hanneke
    Nyborg, Christina Junker
    Bertelsen, Anders Smedegaard
    Smeenk, Robert Jan
    Smith, Gillian
    Michalski, Jeff
    Baumann, Brian C.
    Hafeez, Shaista
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [25] MR-Guided Radiotherapy for Brain and Spine Tumors
    Maziero, Danilo
    Straza, Michael W.
    Ford, John C.
    Bovi, Joseph A.
    Diwanji, Tejan
    Stoyanova, Radka
    Paulson, Eric S.
    Mellon, Eric A.
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [26] Reduced Field-Of-View Diffusion Weighted MRI On An MR-Guided Radiotherapy System
    Pham, J.
    Gao, Y.
    Low, D.
    Hu, P.
    Yang, Y.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [27] Soft-tissue prostate intrafraction motion tracking in 3D cine-MR for MR-guided radiotherapy
    Keizer, D. M. de Muinck
    Kerkmeijer, L. G. W.
    Maspero, M.
    Andreychenko, A.
    van Zyp, J. R. N. van der Voort
    van den Berg, C. A. T.
    Raaymakers, B. W.
    Lagendijk, J. J. W.
    de Boer, J. C. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (23):
  • [28] Preliminary results from ongoing protocol of MR-guided adaptive radiotherapy for gastric lymphoma
    Rechner, L.
    Hansen, R. H.
    Boye, K.
    Specht, L.
    Petersen, P. M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S935 - S936
  • [29] Comparison of liver tumor motion with and without abdominal compression using Cine-MRI
    Eccles, C. L.
    Patel, R.
    Lockwood, G.
    Purdie, T.
    Kirilova, A.
    Haider, M.
    Dawson, L. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S50 - S50
  • [30] Delivered dose reconstruction for MR-guided SBRT of pancreatic tumors with fast 3D cine MRI
    Grimbergen, G.
    Potgens, G.
    Eijkelenkamp, H.
    Raaymakers, B.
    Intven, M.
    Meijer, G.