Simulation of Fluid Flow in the Top-Bottom Combined Blowing Converter

被引:1
|
作者
Liu, Zhao [1 ]
Cheng, Shusen [1 ]
Peng, Jipeng [1 ]
机构
[1] Univ Sci & Technol Beijing, Sch Met & Ecol Engn, Xueyuan Rd 30, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
converter; flow field; combined blowing; physical model; numerical simulation; MASS-TRANSFER; COLD MODEL; IMPINGEMENT; JETS; BATH; DYNAMICS;
D O I
10.3390/met14010056
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The flow in the top-bottom combined blowing converter has an important impact on processes such as slagging, dephosphorization, decarburization, the heating of molten steel, and the homogenization of steel composition and temperature. A 1/6 reduced scale model based on a 210 t converter was used for the mathematical simulation. The validity of the model was verified by comparing the variation in cavity sizes caused by changes in the lance height and flow rate of the physical model with the numerical results. It was found that, in the bottom blowing converter, the area with higher velocity was distributed in the inverted conical plume. In top blowing, the area with higher velocity was distributed on the surface of a molten bath. The area of higher molten bath velocity in the combined blowing converter further increased. Compared with the top blowing converter, the increased percentage of the area-averaged velocity in the combined blowing converter first increased and then decreased as the distance from the bottom increased. When the top blowing flow rate changed, the combined blowing made the velocity change at the top of a molten bath smaller. The decrease in lance height significantly reduced the ratio of "inactive zone", while the effect of the change in the flow rate was slight.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] TOP-BOTTOM DOUBLET IN THE SPHALERON BACKGROUND
    MORENO, J
    OAKNIN, DH
    QUIROS, M
    PHYSICS LETTERS B, 1995, 363 (03) : 189 - 195
  • [32] COMPARISON BETWEEN CONVERTER PROCESSES USING TOP AND BOTTOM BLOWING
    BERTHET, A
    REVUE DE METALLURGIE-CAHIERS D INFORMATIONS TECHNIQUES, 1980, 77 (03): : 213 - 228
  • [33] COKE ADDITION AND SULFUR VAPORIZATION IN TOP AND BOTTOM BLOWING CONVERTER
    TAOKA, K
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1984, 70 (12): : 1022 - 1022
  • [34] Effect of top and bottom blowing conditions on metallurgical characteristics in converter
    Higuchi, Y
    Tago, Y
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2000, 86 (10): : 14 - 19
  • [35] OPTIMIZATION OF THE BLOWING SEQUENCE IN A TOP AND BOTTOM BLOWING CONVERTER CONTAINING PRETREATED HOT METAL
    KATO, Y
    TAKAHASHI, Y
    SAKURAYA, T
    FUJII, T
    OMIYA, S
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1990, 76 (04): : 560 - 567
  • [36] Numerical simulation of multiphase flow induced by bottom blowing limestone powder in converter steelmaking
    Zhang, Kaixuan
    Wang, Shuhuan
    Li, Chenxiao
    Yuan, Zhipeng
    Zhang, Yanchao
    POWDER TECHNOLOGY, 2025, 449
  • [37] Top-bottom effects in double diffraction
    Tietz, LA
    Carter, CB
    McKernan, S
    ULTRAMICROSCOPY, 1995, 60 (02) : 241 - 246
  • [38] Steel-slag mass transfer in steel converter, bottom and top/bottom combined blowing through cold model experiments
    Martín, M
    Rendueles, M
    Díaz, M
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2005, 83 (A9): : 1076 - 1084
  • [39] Fluid–Solid Coupling Simulation on the Temperature Distribution of Tuyere Used for Oxygen Bottom Blowing Converter
    Shaoyan Hu
    Rong Zhu
    Runzao Liu
    Kai Dong
    Zhihui Li
    Metallurgical and Materials Transactions B, 2018, 49 : 3317 - 3329
  • [40] MGO-C TUYERE BRICK FOR THE TOP AND BOTTOM BLOWING CONVERTER
    SATO, Y
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1985, 71 (04): : S226 - S226