Continuous monitoring with a permanently installed high-resolution ultrasonic phased array

被引:8
|
作者
Sun, Xiaoyu [1 ,2 ,3 ]
Croxford, Anthony J. [1 ]
Drinkwater, Bruce W. [1 ]
机构
[1] Univ Bristol, Dept Mech Engn, Ultrason & Non Destruct Testing Grp, Univ Walk, Bristol, England
[2] Univ Bristol, Bristol Ctr Funct Nanomat, HH Wills Phys Lab, Bristol, England
[3] Univ Bristol, Dept Mech Engn, Ultrason & Non Destruct Testing Grp, Queens Bldg, Univ Walk, Bristol BS8 1TR, Avon, England
关键词
Ultrasonic arrays; non-destructive testing (NDT); structural health monitoring (SHM); long-term continuous monitoring; high-resolution ultrasonic imaging; WAFER ACTIVE SENSORS; PLACEMENT; SYSTEM;
D O I
10.1177/14759217231152413
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
High-resolution defect detection is an integral part of non-destructive testing (NDT). Ultrasonic array transducers have been developed to respond to this need and provide high-resolution images for such applications. At present, high-resolution imaging is achieved by ultrasonic array design, such as enhanced transducer materials, and optimised element geometry to fulfil inspection requirements and miniaturise imaging artefacts, etc. This paper presents a novel ultrasonic array and controller system design strategy that can miniaturise the array and reduce manufacturing cost of the entire array system. This then enables the permanent or semi-permanent installation of arrays onto structures and long-term continuous structural health monitoring (SHM). The array geometry is designed as a compromise between the required imaging performance for the desired application and the fabrication cost for permanent installation. A prototype array transducer is constructed from piezoceramic elements bonded to a flexible printed circuit (FPC) substrate and then permanently installed on example structures to demonstrate long-term monitoring. Improved long-term sensitivity to defect growth is achieved by applying a compensation strategy for velocity and phase changes with temperature. Results show that a 5 MHz, 18-element prototype array can detect changes as small as 0.1 mm in the diameter of a side-drilled hole (SDH) defect after 3 months of continuous monitoring.
引用
收藏
页码:3451 / 3464
页数:14
相关论文
共 50 条
  • [1] High-resolution phased array ultrasonic imaging with propagator method
    Zhang, Xiaofei
    Chen, Han
    ICIC Express Letters, 2014, 8 (05): : 1433 - 1438
  • [2] A WAVEGUIDE ULTRASONIC PHASED ARRAY RADAR FOR HIGH TEMPERATURE EQUIPMENT MONITORING
    Yin, Xiaowei
    Shen, Yanfeng
    PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 14, 2020,
  • [3] A high-resolution structural health monitoring system based on SH wave piezoelectric transducers phased array
    Huan, Qiang
    Chen, Mingtong
    Su, Zhongqing
    Li, Faxin
    ULTRASONICS, 2019, 97 : 29 - 37
  • [4] Wide-steering-angle high-resolution optical phased array
    YINGZHI LI
    BAISONG CHEN
    QUANXIN NA
    QIJIE XIE
    MIN TAO
    LANXUAN ZHANG
    ZIHAO ZHI
    YUXUAN LI
    XIAOBIN LIU
    XIANSHU LUO
    GUOQIANG LO
    FENGLI GAO
    XUEYAN LI
    JUNFENG SONG
    Photonics Research, 2021, 9 (12) : 2511 - 2518
  • [5] Wide-steering-angle high-resolution optical phased array
    YINGZHI LI
    BAISONG CHEN
    QUANXIN NA
    QIJIE XIE
    MIN TAO
    LANXUAN ZHANG
    ZIHAO ZHI
    YUXUAN LI
    XIAOBIN LIU
    XIANSHU LUO
    GUOQIANG LO
    FENGLI GAO
    XUEYAN LI
    JUNFENG SONG
    Photonics Research, 2021, (12) : 2511 - 2518
  • [6] Wide-steering-angle high-resolution optical phased array
    Li, Yingzhi
    Chen, Baisong
    Na, Quanxin
    Xie, Qijie
    Tao, Min
    Zhang, Lanxuan
    Zhi, Zihao
    Li, Yuxuan
    Liu, Xiaobin
    Luo, Xianshu
    Lo, Guoqiang
    Gao, Fengli
    Li, Xueyan
    Song, Junfeng
    PHOTONICS RESEARCH, 2021, 9 (12) : 2511 - 2518
  • [7] High-Resolution Ultrasonic Imaging of Dento-Periodontal Tissues Using a Multi-Element Phased Array System
    Kim-Cuong T. Nguyen
    Lawrence H. Le
    Neelambar R. Kaipatur
    Rui Zheng
    Edmond H. Lou
    Paul W. Major
    Annals of Biomedical Engineering, 2016, 44 : 2874 - 2886
  • [8] High-resolution ultrasonic imaging using an etalon detector array
    Huang, Sheng-Wen
    Hou, Yang
    Ashkenazi, Shai
    O'Donnell, Matthew
    APPLIED PHYSICS LETTERS, 2008, 93 (11)
  • [9] High-Resolution Ultrasonic Imaging of Dento-Periodontal Tissues Using a Multi-Element Phased Array System
    Nguyen, Kim-Cuong T.
    Le, Lawrence H.
    Kaipatur, Neelambar R.
    Zheng, Rui
    Lou, Edmond H.
    Major, Paul W.
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (10) : 2874 - 2886
  • [10] TESTING OF PERMANENTLY INSTALLED PIEZOELECTRIC ULTRASONIC GUIDED WAVE TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING
    Loveday, Philip W.
    Fromme, Paul
    PROCEEDINGS OF 2024 51ST ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, QNDE2024, 2024,