Wear, Osteolysis, and Aseptic Loosening Following Total Hip Arthroplasty in Young Patients with Highly Cross-Linked Polyethylene: A Review of Studies with a Follow-Up of over 15 Years

被引:4
|
作者
Deans, Christopher F. [1 ]
Buckner, Brandt C. [1 ]
Garvin, Kevin L. [1 ]
机构
[1] Univ Nebraska Med Ctr, Dept Orthopaed Surg & Rehabil, 985640 Nebraska Med Ctr, Omaha, NE 68198 USA
关键词
highly cross-linked polyethylene; total hip arthroplasty; young arthroplasty; polyethylene wear; ACETABULAR COMPONENT; BIOLOGICAL-ACTIVITY; REVISION SURGERY; UNITED-STATES; MINIMUM; CEMENTLESS; RATES; THA; MULTICENTER; FIXATION;
D O I
10.3390/jcm12206615
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Total hip arthroplasty (THA) has in recent years trended toward a younger, more physically demanding patient population. Mid- to long-term studies of all ages of THA patients using highly cross-linked polyethylene (HXLPE) have been favorable, but concerns about its long-term failure and wear-related complications remain for young THA patients. In this narrative review, a search of the PubMed/MEDLINE and Cochrane databases was performed, and we identified six studies with a minimum 15-year follow-up of HXLPE with various femoral head materials. Wear-related revisions were exceedingly low for patients under the age of 55, with variable reports of non-clinically significant osteolysis. Higher activity levels, a larger femoral head size, and femoral head material were not associated with greater long-term wear rates. Young THA with metal or ceramic on HXLPE is exceedingly durable with favorable outcomes at follow-ups of over 15 years.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Cementless Total Hip Arthroplasty With Alumina-on-Highly Cross-Linked Polyethylene Bearing in Young Patients With Femoral Head Osteonecrosis
    Kim, Young-Hoo
    Choi, Yoowang
    Kim, Jun-Shik
    JOURNAL OF ARTHROPLASTY, 2011, 26 (02): : 218 - 223
  • [42] Clinical performance of a durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years
    Dorr, LD
    Wan, ZN
    Shahrdar, C
    Sirianni, L
    Boutary, M
    Yun, A
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (08): : 1816 - 1821
  • [43] Effect of polyethylene wear on osteolysis in cementless primary total hip arthroplasty - Minimal 5-year follow-up study
    Han, CD
    Choe, WS
    Yoo, JH
    JOURNAL OF ARTHROPLASTY, 1999, 14 (06): : 714 - 723
  • [44] Early failure for wear after ceramic-on-highly cross-linked polyethylene total hip arthroplasty: a case report
    Li, Chenkai
    Zhang, Haining
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [45] Early failure for wear after ceramic-on-highly cross-linked polyethylene total hip arthroplasty: a case report
    Chenkai Li
    Haining Zhang
    BMC Musculoskeletal Disorders, 21
  • [46] Reduction of osteolysis with use of Marathon cross-linked polyethylene - A concise follow-up, at a minimum of five years, of a previous report
    Bitsch, Rudi G.
    Loidolt, Travis
    Heisel, Christian
    Ball, Scott
    Schmalzried, Thomas P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (07): : 1487 - 1491
  • [47] Highly Cross-Linked Polyethylene in Patients 50 Years of Age and Younger: A 20-year Follow-Up Analysis
    Zitsch, Bradford P.
    Cahoy, Kevin M.
    Urban, Nathanael D.
    Buckner, Brandt C.
    Garvin, Kevin L.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (09): : S145 - S152
  • [48] No Revisions Attributable to Wear of Highly Cross-Linked Polyethylene Liners: A Long-Term Follow-Up Study
    Wright, Breydan H.
    Hadley, Matthew L.
    Harmer, Joshua R.
    Fruth, Kristin M.
    Sierra, Rafael J.
    Couch, Cory G.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (09): : S347 - S352
  • [49] Minimum five-year wear rate of metal-on-highly cross-linked polyethylene in primary total hip arthroplasty
    Caroline Scemama
    Claudio Dora
    Jean Langlois
    Moussa Hamadouche
    International Orthopaedics, 2015, 39 : 1051 - 1055
  • [50] Minimum five-year wear rate of metal-on-highly cross-linked polyethylene in primary total hip arthroplasty
    Scemama, Caroline
    Dora, Claudio
    Langlois, Jean
    Hamadouche, Moussa
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (06) : 1051 - 1055