Can a Musculoskeletal Model Adapted to Knee Implant Geometry Improve Prediction of 3D Contact Forces and Moments?

被引:0
|
作者
Guitteny, Sacha [1 ]
Aissaoui, Rachid [2 ]
Dumas, Raphael [1 ]
机构
[1] Univ Claude Bernard Lyon 1, Univ Lyon, Univ Gustave Eiffel, LBMC UMR T 9406, F-69622 Lyon, France
[2] Ecole Technol Super, Dept Genie Syst, Lab Rech Imagerie & Orthopedie LIO, Montreal, PQ, Canada
关键词
Osteoarthritis; Musculoskeletal modeling; Tibiofemoral contact loads; Contact point location; JOINT CONTACT; MUSCLE FORCES; KINEMATICS; GAIT; COMPONENT; ALIGNMENT; SYSTEM; WEAR;
D O I
10.1007/s10439-023-03216-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tibiofemoral contact loads are crucial parameters in the onset and progression of osteoarthrosis. While contact loads are frequently estimated from musculoskeletal models, their customization is often limited to scaling musculoskeletal geometry or adapting muscle lines. Moreover, studies have usually focused on superior-inferior contact force without investigating three-dimensional contact loads. Using experimental data from six patients with instrumented total knee arthroplasty (TKA), this study customized a lower limb musculoskeletal model to consider the positioning and the geometry of the implant at knee level. Static optimization was performed to estimate tibiofemoral contact forces and contact moments as well as musculotendinous forces. Predictions from both a generic and a customized model were compared to the instrumented implant measurements. Both models accurately predict superior-inferior (SI) force and abduction-adduction (AA) moment. Notably, the customization improves prediction of medial-lateral (ML) force and flexion-extension (FE) moments. However, there is subject-dependent variability in the prediction of anterior-posterior (AP) force. The customized models presented here predict loads on all joint axes and in most cases improve prediction. Unexpectedly, this improvement was more limited for patients with more rotated implants, suggesting a need for further model adaptations such as muscle wrapping or redefinition of hip and ankle joint centers and axes.
引用
收藏
页码:1872 / 1883
页数:12
相关论文
共 34 条
  • [21] A 3D musculoskeletal model of the western lowland gorilla hind limb: moment arms and torque of the hip, knee and ankle
    Goh, Colleen
    Blanchard, Mary L.
    Crompton, Robin H.
    Gunther, Michael M.
    Macaulay, Sophie
    Bates, Karl T.
    JOURNAL OF ANATOMY, 2017, 231 (04) : 568 - 584
  • [22] Reliable prediction of implant size and axial alignment in AI-based 3D preoperative planning for total knee arthroplasty
    Lan, Qing
    Li, Shulin
    Zhang, Jiahao
    Guo, Huiling
    Yan, Laipeng
    Tang, Faqiang
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [23] A 3D Biphasic Finite element model of the human knee joint for the study of tibiofemoral contact and fluid pressurization
    Guo, Hongqiang
    Suzanne, A. Maher
    Spilker, Robert L.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [24] DYNAMIC PREDICTION OF ELASTIC-SUPPORTED ROTOR WITH FRICTION DAMPER BASED ON 3D CONTACT MODEL
    Fan, Y.
    Wang, S. S.
    Wu, Y. G.
    Zhang, S. Z.
    Shen, Y. W.
    Chen, M. M.
    PROCEEDINGS OF ASME TURBO EXPO 2024: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2024, VOL 10B, 2024,
  • [25] A 3D brain unit model to further improve prediction of local drug distribution within the brain
    Vendel, Esmee
    Rottschafer, Vivi
    de Lange, Elizabeth C. M.
    PLOS ONE, 2020, 15 (09):
  • [26] A finite element 3D model of in vivo human knee joint based on MRI for the tibiofemoral joint contact analysis
    Hao, Zhixiu
    Jim, Dewen
    Zhang, Yu
    Zhang, Jichuan
    DIGITAL HUMAN MODELING, 2007, 4561 : 616 - 622
  • [27] Prediction model for dilation behaviors of soft rock joints considering degradation of actual contact 3D roughness
    Ban L.
    Du W.
    Hou Y.
    Qi C.
    Tao Z.
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2024, 46 (05): : 1008 - 1017
  • [28] 3D Dose Prediction Model for Head and Neck Cancer Patients by Combining Field Geometry Information with Patient Images
    Czeizler, E.
    Hakala, M.
    Basiri, S.
    Kuusela, E.
    MEDICAL PHYSICS, 2019, 46 (06) : E156 - E156
  • [29] On the prediction of hole geometry in laser trepanning drilling: A generic 3D analytical model considering drill system structure
    Ye, Muyang
    Xiu, Haohua
    Thein, Chung Ket
    Jiang, Boyan
    Zhao, Yongjie
    Liu, Gongyu
    Li, Hao Nan
    OPTICS AND LASER TECHNOLOGY, 2024, 177
  • [30] A 3D Printed Human iPSC-derived Hepatic Model than can Improve In Vitro Liver Functional Maturation
    Ma, X.
    Qu, X.
    Zhu, W.
    Li, Y.
    Yuan, S.
    Zhang, H.
    Zanella, F.
    Sheikh, F.
    Chien, S.
    Chen, S.
    TISSUE ENGINEERING PART A, 2015, 21 : S77 - S77