Can a Musculoskeletal Model Adapted to Knee Implant Geometry Improve Prediction of 3D Contact Forces and Moments?

被引:0
|
作者
Guitteny, Sacha [1 ]
Aissaoui, Rachid [2 ]
Dumas, Raphael [1 ]
机构
[1] Univ Claude Bernard Lyon 1, Univ Lyon, Univ Gustave Eiffel, LBMC UMR T 9406, F-69622 Lyon, France
[2] Ecole Technol Super, Dept Genie Syst, Lab Rech Imagerie & Orthopedie LIO, Montreal, PQ, Canada
关键词
Osteoarthritis; Musculoskeletal modeling; Tibiofemoral contact loads; Contact point location; JOINT CONTACT; MUSCLE FORCES; KINEMATICS; GAIT; COMPONENT; ALIGNMENT; SYSTEM; WEAR;
D O I
10.1007/s10439-023-03216-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tibiofemoral contact loads are crucial parameters in the onset and progression of osteoarthrosis. While contact loads are frequently estimated from musculoskeletal models, their customization is often limited to scaling musculoskeletal geometry or adapting muscle lines. Moreover, studies have usually focused on superior-inferior contact force without investigating three-dimensional contact loads. Using experimental data from six patients with instrumented total knee arthroplasty (TKA), this study customized a lower limb musculoskeletal model to consider the positioning and the geometry of the implant at knee level. Static optimization was performed to estimate tibiofemoral contact forces and contact moments as well as musculotendinous forces. Predictions from both a generic and a customized model were compared to the instrumented implant measurements. Both models accurately predict superior-inferior (SI) force and abduction-adduction (AA) moment. Notably, the customization improves prediction of medial-lateral (ML) force and flexion-extension (FE) moments. However, there is subject-dependent variability in the prediction of anterior-posterior (AP) force. The customized models presented here predict loads on all joint axes and in most cases improve prediction. Unexpectedly, this improvement was more limited for patients with more rotated implants, suggesting a need for further model adaptations such as muscle wrapping or redefinition of hip and ankle joint centers and axes.
引用
收藏
页码:1872 / 1883
页数:12
相关论文
共 34 条
  • [1] Can a Musculoskeletal Model Adapted to Knee Implant Geometry Improve Prediction of 3D Contact Forces and Moments?
    Sacha Guitteny
    Rachid Aissaoui
    Raphael Dumas
    Annals of Biomedical Engineering, 2023, 51 : 1872 - 1883
  • [2] Influence of musculoskeletal model parameter values on prediction of accurate knee contact forces during walking
    Serrancoli, Gil
    Kinney, Allison L.
    Fregly, Benjamin J.
    MEDICAL ENGINEERING & PHYSICS, 2020, 85 (85) : 35 - 47
  • [3] Development of a Full Flexion 3D Musculoskeletal Model of the Knee Considering Intersegmental Contact During High Knee Flexion Movements
    Kingston, David C.
    Acker, Stacey M.
    JOURNAL OF APPLIED BIOMECHANICS, 2020, 36 (06) : 444 - 456
  • [4] 3D projection of the LuGre friction model adapted to varying normal forces
    Colantonio, Lorenzo
    Dehombreux, Pierre
    Hajzman, Michal
    Verlinden, Olivier
    MULTIBODY SYSTEM DYNAMICS, 2022, 55 (03) : 267 - 291
  • [5] 3D projection of the LuGre friction model adapted to varying normal forces
    Lorenzo Colantonio
    Pierre Dehombreux
    Michal Hajžman
    Olivier Verlinden
    Multibody System Dynamics, 2022, 55 : 267 - 291
  • [6] In Vivo Knee Contact Force Prediction Using Patient-Specific Musculoskeletal Geometry in a Segment-Based Computational Model
    Ding, Ziyun
    Nolte, Daniel
    Tsang, Chui Kit
    Cleather, Daniel J.
    Kedgley, Angela E.
    Bull, Anthony M. J.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (02):
  • [7] DEVELOPMENT OF METHOD FOR REVERSE ENGINEERING IN CREATION OF 3D CAD MODEL OF KNEE IMPLANT
    Rajic, Aleksandar
    Desnica, Eleonora
    Stojadinovic, Slobodan
    Nedelcu, Dorian
    FACTA UNIVERSITATIS-SERIES MECHANICAL ENGINEERING, 2013, 11 (01) : 45 - 54
  • [8] Prediction of ground reaction forces and moments and joint kinematics and kinetics by inertial measurement units using 3D forward dynamics model
    Haraguchi, Naoto
    Hase, Kazunori
    Journal of Biomechanical Science and Engineering, 2024, 19 (01):
  • [9] A 3D lower limb musculoskeletal model for simultaneous estimation of musculo-tendon, joint contact, ligament and bone forces during gait
    Moissenet, Florent
    Cheze, Laurence
    Dumas, Raphael
    JOURNAL OF BIOMECHANICS, 2014, 47 (01) : 50 - 58
  • [10] Can a number of diagrams linked to a proof task in 3D geometry improve proving ability?
    Aehsan Haj-Yahya
    Mathematics Education Research Journal, 2023, 35 : 215 - 236