Additive manufacturing leveraged microfluidic setup for sample to answer colorimetric detection of pathogens

被引:3
|
作者
Yedire, Sripadh Guptha [1 ]
Hosseini, Imman Isaac [1 ]
Shieh, Hamed [1 ]
Jahromi, Arash Khorrami [1 ]
AbdelFatah, Tamer [1 ]
Jalali, Mahsa [1 ]
Mahshid, Sara [1 ,2 ]
机构
[1] McGill Univ, Dept Bioengn, Montreal, PQ H3A 0C3, Canada
[2] McGill Univ, Div Expt Med, Montreal, PQ H3A 0C3, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会; 加拿大健康研究院;
关键词
POINT; SENSORS; DEVICES; DIAGNOSTICS;
D O I
10.1039/d3lc00429e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Colorimetric readout for the detection of infectious diseases is gaining traction at the point of care/need owing to its ease of analysis and interpretation, and integration potential with highly specific loop-mediated amplification (LAMP) assays. However, coupling colorimetric readout with LAMP is rife with challenges including, rapidity, inter-user variability, colorimetric signal quantification, and user involvement in sequential steps of the LAMP assay, hindering its application. To address these challenges, for the first time, we propose a remotely smartphone-operated automated setup consisting of (i) an additively manufactured microfluidic cartridge, (ii) a portable reflected-light imaging setup with controlled epi-illumination (PRICE) module, and (iii) a control and data analysis module. The microfluidic cartridge facilitates sample collection, lysis, mixing of amplification reagents stored on-chip, and subsequent isothermal heating for initiation of amplification in a novel way by employing tunable elastomeric chambers and auxiliary components (heaters and linear actuators). PRICE offers a new imaging setup that captures the colorimetric change of the amplification media over a plasmonic nanostructured substrate in a controlled and noise-free environment for rapid minute-scale nucleic acid detection. The control and data analysis module employs microprocessors to automate cartridge operation in tandem with the imaging module. The different device components were characterized individually and finally, as a proof of concept, SARS-CoV-2 wild-type RNA was detected with a turnaround time of 13 minutes, showing the device's clinical feasibility. The suggested automated device can be adopted in future iterations for other detection and molecular assays that require sequential fluid handling steps. Additive manufacturing leveraged automated sample-answer microfluidic setup for colorimetric detection of pathogen.
引用
收藏
页码:4134 / 4145
页数:12
相关论文
共 40 条
  • [21] Origami-based "Book" shaped three-dimensional electrochemical paper microdevice for sample-to-answer detection of pathogens
    He, Tao
    Li, Jingwen
    Liu, Lisheng
    Ge, Shenguang
    Yan, Mei
    Liu, Haiyun
    Yu, Jinghua
    RSC ADVANCES, 2020, 10 (43) : 25808 - 25816
  • [22] A sample-to-answer DNA detection microfluidic system integrating sample pretreatment and smartphone-readable gradient plasmonic photothermal continuous-flow PCR
    Zhang, Zengming
    Zhao, Shuhao
    Jiang, Lei
    Wu, Junjun
    Zhao, Wenhan
    Guo, Xiaoniu
    Peng, Niancai
    Hu, Fei
    ANALYST, 2022, 147 (21) : 4876 - 4887
  • [23] Static self-directed sample dispensing into a series of reaction wells on a microfluidic card for parallel genetic detection of microbial pathogens
    Robert D. Stedtfeld
    Yen-Cheng Liu
    Tiffany M. Stedtfeld
    Tanja Kostic
    Maggie Kronlein
    Onnop Srivannavit
    Walid T. Khalife
    James M. Tiedje
    Erdogan Gulari
    Mary Hughes
    Brett Etchebarne
    Syed A. Hashsham
    Biomedical Microdevices, 2015, 17
  • [24] Static self-directed sample dispensing into a series of reaction wells on a microfluidic card for parallel genetic detection of microbial pathogens
    Stedtfeld, Robert D.
    Liu, Yen-Cheng
    Stedtfeld, Tiffany M.
    Kostic, Tanja
    Kronlein, Maggie
    Srivannavit, Onnop
    Khalife, Walid T.
    Tiedje, James M.
    Gulari, Erdogan
    Hughes, Mary
    Etchebarne, Brett
    Hashsham, Syed A.
    BIOMEDICAL MICRODEVICES, 2015, 17 (05)
  • [25] Sample-to-Answer Hepatitis B Virus DNA Detection from Whole Blood on a Centrifugal Microfluidic Platform with Double Rotation Axes
    Li, Lei
    Miao, Baogang
    Li, Zheng
    Sun, Zhengming
    Peng, Niancai
    ACS SENSORS, 2019, 4 (10) : 2738 - 2745
  • [26] Multiplex Detection of Gram-Negative Pathogens from Blood Culture Bottles with GenMark's Innovative Sample-to-Answer Platform
    Ivy, C. A.
    Sikhamsay, N. N.
    Haq, R.
    Brown, B. A.
    Freeman-Cook, L.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2014, 16 (06): : 739 - 739
  • [27] Multiplex Detection of Gram-Positive Pathogens from Blood Culture Bottles with GenMark's Innovative Sample-to-Answer Platform
    Yousif, S.
    Heiling, T.
    Martinez, M.
    Liang, H.
    Maer, A.
    Chen, Y.
    Freeman-Cook, L.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2014, 16 (06): : 738 - 738
  • [28] Integrated microfluidic device of DNA extraction, recombinase polymerase amplification and micro-capillary electrophoresis for sample-to-answer detection of Salmonella Typhimurium
    Nguyen, Van Dan
    Sureshkumar, Gayathri
    Seo, Tae Seok
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 435
  • [29] Microfluidic colorimetric detection platform with sliding hybrid PMMA/paper microchip for human urine and blood sample analysis (vol 231, 122362, 2021)
    Laurenciano, Carl Jay D.
    Tseng, Chin-Chung
    Chen, Szu-Jui
    Lu, Song-Yu
    Tayo, Lemmuel L.
    Fu, Lung-Ming
    TALANTA, 2021, 234
  • [30] Sample-in-answer-out centrifugal microfluidic chip reaction biosensor powered by Thermus thermophilus Argonaute (TtAgo) for rapid, highly sensitive and multiplexed molecular diagnostics of foodborne bacterial pathogens
    Wang, Nan
    Zhang, Qiang
    Liu, Yajie
    Huang, Baoyan
    Man, Shuli
    Ye, Shengying
    Ma, Long
    CHEMICAL ENGINEERING JOURNAL, 2024, 495