Effect of Auricular Position on Body Temperature Measurement with Tympanic Thermometers: A Quasi Experimental Study

被引:0
|
作者
Orkun, N. [1 ,2 ]
Eser, I [1 ]
机构
[1] Ege Univ, Nursing Fac, Fundamentals Nursing Dept, Bornova, Turkiye
[2] Ege Univ, Nursing Fac, Floor 2,Apartment 50, TR-35100 Bornova, Izmir, Turkiye
关键词
Auricle position; body temperature; COVID-19; nursing practice; tympanic membrane thermometer; HOSPITALS; EAR;
D O I
10.4103/njcp.njcp_389_22
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: With the COVID-19 pandemic, body temperature measurement has begun to be widely used in the diagnosis of the coronavirus disease. When measuring body temperature, it is important to obtain the core temperature measurement. This study compared the results of body temperature obtained with the tympanic membrane thermometer-which is one of the methods that best reflect the body temperature-with or without positioning the auricle. Aims: The aim of this study was to investigate the effect of auricle position on body temperature measurements made with tympanic membrane thermometer in adult patients. Materials and Methods: A quasi-experimental design that employed a pre-test and a post-test was used in this study. A total of 143 patients who fit the inclusion criteria of the study were included in the sample. For analysis of the data, frequencies, percentages, means and standard deviations were calculated, and the significance of the difference between paired values was tested in order to investigate the effects of auricle position on measurement values. Statistical Package for the Social Sciences (SPSS) 22.0 was used in analyzing the data obtained in this study.Results: The difference between the values of measurement taken in these two separate positions was found to be 0.31 0C, and the Bland-Altman plot showed that the differences were distributed systematically around the value 0.31. Conclusions: It was found in the comparison of two positions that there was a significant difference between the tympanic thermometer measurements made by positioning the auricle and those without positioning.
引用
收藏
页码:1595 / 1601
页数:7
相关论文
共 50 条
  • [1] An assessment of infrared tympanic thermometers for body temperature measurement
    Betta, V
    Cascetta, F
    Sepe, D
    PHYSIOLOGICAL MEASUREMENT, 1997, 18 (03) : 215 - 225
  • [2] Measurement of body temperature by use of auricular thermometers versus rectal thermometers in dogs with otitis externa
    González, AM
    Mann, FA
    Preziosi, DE
    Meadows, RL
    Wagner-Mann, CC
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2002, 221 (03) : 378 - 380
  • [3] Comparison between auricular and standard rectal thermometers for the measurement of body temperature in dogs
    Sousa, Marlos G.
    Carareto, Roberta
    Pereira-Junior, Valdo A.
    Aquino, Monally C. C.
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2011, 52 (04): : 403 - 406
  • [4] CORE TEMPERATURE MEASURED IN THE AURICULAR CANAL - COMPARISON BETWEEN 4 DIFFERENT TYMPANIC THERMOMETERS
    JAKOBSSON, J
    NILSSON, A
    CARLSSON, L
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1992, 36 (08) : 819 - 824
  • [5] Analysis of the effect of lying on the ear on body temperature measurement using a tympanic thermometer
    Arslan, Gulsah Gurol
    Eser, Ismet
    Khorshid, Leyla
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2011, 61 (11) : 1065 - 1068
  • [6] The Effect of Pinna Position on Body Temperature Measurements Made with a Tympanic Membrane Thermometer in Pediatric Patients
    Orkun, Nilay
    Eser, Ismet
    JOURNAL OF PEDIATRIC RESEARCH, 2020, 7 (02) : 132 - 138
  • [7] Comparing mercury-in-glass, tympanic and disposable thermometers in measuring body temperature in healthy young people
    Khorshid, L
    Eser, I
    Zaybak, A
    Yapucu, Ü
    JOURNAL OF CLINICAL NURSING, 2005, 14 (04) : 496 - 500
  • [8] Bilateral assessment of body core temperature through axillar, tympanic and inner canthi thermometers in a young population
    Vardasca, Ricardo
    Magalhaes, Carolina
    Marques, Diana
    Moreira, Joana
    Frade, Rita
    Seixas, Aderito
    Mendes, Joaquim
    Ring, Francis
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (09)
  • [9] Effect of crying on infrared tympanic temperature measurement in pediatrics
    Kahyaoglu, O
    Babka, I
    Demirci, C
    Boyer, D
    CLINICAL PEDIATRICS, 1997, 36 (08) : 487 - 488
  • [10] Tympanic measurement of body temperature in stroke patients "turned on its ear''
    Rampen, AJJ
    van Breda, EJ
    Dippel, DWJ
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2005, 76 (07): : 1041 - 1042