Tool Frame Calibration for Robot-Assisted Ultrasonic Testing

被引:2
|
作者
Zhang, Hanming [1 ]
Wang, Jingpin [1 ]
Guo, Canzhi [2 ]
机构
[1] North China Univ Technol, Sch Mech & Mat Engn, Beijing 100041, Peoples R China
[2] Jiangsu Univ, Sch Mech Engn, Zhenjiang 212013, Peoples R China
关键词
ultrasonic testing; robot-assisted; calibration; tool frame; KINEMATIC CALIBRATION; SYSTEM;
D O I
10.3390/s23218820
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tool frame calibration has been widely used in robot-assisted printing, welding, and grinding, but it is not suitable for ultrasonic testing because the robot is submerged in water. The purpose of this paper is to present a tool frame calibration method, which is suitable for improving the precision of ultrasonic testing. In uniform mediums, sound travels along a straight line like ray. A reflector is fixed in water to reflect ultrasound, which makes it possible to measure distances between incidence points on a reflector and tool center point (TCP) on an ultrasound transducer. In addition, the positions and poses of the end flange are recorded through a robot controller. Finally, an optimization method is applied to calculate the position and pose errors of the tool frame relative to the end flange according to such records. The presented method was implemented in an ultrasonic testing system. We selected 100 incidence points on the reflector to calculate the assembly errors of the transducer. The pulse amplitude rose obviously after calibration, which verifies that this is an effective method. Considering that ultrasonic transducers can be used as a measuring tool, this paper proposes a tool frame calibration method for ultrasonic testing robots without introducing other measuring devices, which draws the conclusion that tool frame can be calibrated through ultrasound.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Robot-assisted ultrasound probe calibration for image-guided interventions
    Paralikar, Atharva
    Mantripragada, Pavan
    Nguyen, Trong
    Arjoune, Youness
    Shekhar, Raj
    Monfaredi, Reza
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2025,
  • [22] Efficiency and Heat Production of Ultrasonic Osteotome Strategy in Robot-Assisted Laminectomy
    Wang, Chengxia
    Li, Zhuofu
    Jiang, Shuai
    Zhong, Woquan
    Li, Weishi
    GLOBAL SPINE JOURNAL, 2024,
  • [23] Depth Camera-Based Robot-Assisted Ultrasonic Lipolysis System
    Yan M.
    Chai G.
    Xie L.
    Journal of Shanghai Jiaotong University (Science), 2022, 27 (01): : 36 - 44
  • [24] Evaluation of a robot-assisted testing system for multisegmental spine specimens
    Schulze, Martin
    Hartensuer, Rene
    Gehweiler, Dominic
    Hoelscher, Uvo
    Raschke, Michael J.
    Vordemvenne, Thomas
    JOURNAL OF BIOMECHANICS, 2012, 45 (08) : 1457 - 1462
  • [25] AUTOMATED FLEXURAL TESTING - COUPLING OF A ROBOT-ASSISTED SYSTEM TO A MINICOMPUTER
    DRISCOLL, C
    DEPAOLIS, J
    VORBRODT, A
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1993, 21 (01) : 65 - 74
  • [26] Robot-assisted Adrenalectomy
    Brunaud, Laurent
    Germain, Adeline
    Zarnegar, Rasa
    Cuny, Thomas
    Ayav, Ahmet
    Bresler, Laurent
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2011, 21 (04): : 248 - 254
  • [27] Robot-assisted sacrocolpopexy
    Stoliar, G
    Corica, FA
    Sala, LG
    Borin, JF
    Lee, DY
    McDougall, EM
    Hovey, RM
    JOURNAL OF UROLOGY, 2005, 173 (04): : 136 - 136
  • [28] ROBOT-ASSISTED FABRICATION
    KRAUSKOPF, B
    MANUFACTURING ENGINEERING, 1984, 93 (03): : 114 - 115
  • [29] Robot-assisted lobectomy
    Ashton, RC
    Connery, CP
    Swistel, DG
    DeRose, JJ
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (01): : 292 - 293
  • [30] Robot-Assisted Acupuncture
    Lan, Kun-Chan
    Li, Guan-Sheng
    Zhang, Jun-Xiang
    2019 IEEE INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING AND COMMUNICATIONS WORKSHOPS (PERCOM WORKSHOPS), 2019, : 338 - 339