Evaluation of Uterine Fibroid Vascularity Using Contrast-Enhanced Ultrasound in Comparison with Contrast-Enhanced Magnetic Resonance Imaging

被引:0
|
作者
Machado, Priscilla [1 ,2 ]
Tan, Allison [1 ]
Forsberg, Flemming [1 ]
Gonsalves, Carin F. [1 ]
机构
[1] Thomas Jefferson Univ, Dept Radiol, Philadelphia, PA USA
[2] Thomas Jefferson Univ, Dept Radiol, 132 South 10th St,Main 763M, Philadelphia, PA 19107 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2024年 / 50卷 / 03期
基金
美国国家卫生研究院;
关键词
Uterine fibroids; Contrast -enhanced ultrasound; Ultrasound imaging; Magnetic resonance imaging; Vascularity; ARTERY EMBOLIZATION; RISK; EPIDEMIOLOGY; LEIOMYOMATA; AGENTS; MRI;
D O I
10.1016/j.ultrasmedbio.2023.11.012
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective: The aim of the work described here was to assess uterine fibroid vascularity using contrast -enhanced ultrasound (CEUS) as compared with magnetic resonance imaging (MRI). Methods: Forty women diagnosed with symptomatic uterine fibroids scheduled for uterine artery embolization (UAE) were enrolled in this institutional review board -approved study. Before UAE, participants underwent CEUS examination with an Aplio i800 scanner (Canon Medical Systems, Tustin, CA, USA) with curvilinear array (8C1). CEUS was performed using 2.0 mL of the ultrasound contrast agent Lumason (Bracco, Milan, Italy) administered intravenously. Digital CEUS clips were acquired and randomized offline, and fibroids were characterized as hyper- or hypovascular. MRI was used as reference standard for fibroid vascularity and compared with CEUS. Results were analyzed using McNemar's test. Results: Forty participants were enrolled in the trial. One patient did not proceed with the UAE procedure and one patient refused pre -procedure MRI because of claustrophobia. Therefore, 38 participants underwent CEUS and MRI examinations before UAE. Hypervascular fibroids were seen on MRI and CEUS in 24 and 26 participants, respectively. Hypovascular fibroids were seen with MRI and CEUS in 14 and 12 participants, respectively. Fibroids characterized as hypovascular in two participants by MRI were characterized as hypervascular by CEUS. CEUS and MRI findings were similar in 36 of 38 participants, corresponding to an accuracy of 95% (p = 0.62). Conclusion: Contrast -enhanced ultrasound can accurately assess uterine fibroid vascularity, serving as a potential alternative to MRI in determination of the vascularity of uterine fibroids.
引用
收藏
页码:394 / 398
页数:5
相关论文
共 50 条
  • [41] Vascularity in fibroadenomas: Comparison of contrast-harmonic imaging and contrast-enhanced power Doppler
    Huber, S
    Stiskal, M
    Steinbach, R
    Czembirek, H
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (10): : 830 - 835
  • [42] Honeycomb Appearance on Contrast-Enhanced Magnetic Resonance Imaging
    Omega, Michelle
    Bayasi, Ferris
    Shields, Carol L.
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2022, 59 (05) : 286 - 287
  • [43] Pulse sequences for contrast-enhanced magnetic resonance imaging
    Graves, Martin J.
    RADIOGRAPHY, 2007, 13 : E20 - E30
  • [44] Dynamic contrast-enhanced imaging of the breast with magnetic resonance
    Cron, GO
    Santyr, G
    Kelcz, F
    IMTC/97 - IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE: SENSING, PROCESSING, NETWORKING, PROCEEDINGS VOLS 1 AND 2, 1997, : 1354 - 1356
  • [45] CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING OF THE ABDOMEN
    BROWN, ED
    SEMELKA, RC
    MAGNETIC RESONANCE QUARTERLY, 1994, 10 (02) : 97 - 124
  • [46] CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING OF THE BREAST
    HEYWANGKOBRUNNER, SH
    INVESTIGATIVE RADIOLOGY, 1994, 29 (01) : 94 - 104
  • [47] Diagnostic Value of Contrast-Enhanced Digital Mammography versus Contrast-Enhanced Magnetic Resonance Imaging for the Preoperative Evaluation of Breast Cancer
    Kim, Eun Young
    Youn, Inyoung
    Lee, Kwan Ho
    Yun, Ji-Sup
    Park, Yong Lai
    Park, Chan Heun
    Moon, Juhee
    Choi, Seon Hyeong
    Choi, Yoon Jung
    Ham, Soo-Youn
    Kook, Shin Ho
    JOURNAL OF BREAST CANCER, 2018, 21 (04) : 453 - 462
  • [48] Contrast-enhanced Ultrasonography Assessment of Therapeutic Efficacy for Ultrasound-guided High-intensity Focused Ultrasound Ablation of Uterine Fibroids: Comparison with Contrast-enhanced Magnetic Resonance
    Wang, Yang
    Wang, Wei
    Ye, Huiyi
    JOURNAL OF MEDICAL ULTRASOUND, 2014, 22 (01) : 22 - 28
  • [49] The use of contrast-enhanced ultrasound in uterine leiomyomas
    ZHANG XinlingZHENG RongqinYANG YueboHUANG DongmeiSONG QianMAO Yongjiang LI Yuhua and ZHENG Zhijuan Department of Ultrasound Department of Gynecology Third Affiliated HospitalSun Yatsen UniversityGuangzhouGuangdong China
    中华医学杂志(英文版), 2010, (21) : 3095 - 3099
  • [50] Contrast-Enhanced Ultrasound
    Hunt, David
    Romero, Javier
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2017, 25 (04) : 725 - +