Multianalyte analysis of volatile compounds in virgin olive oils using SPME-GC with FID or MS detection: results of an international interlaboratory validation

被引:4
|
作者
Garcia-Gonzalez, Diego L. [1 ]
Casadei, Enrico [2 ]
Aparicio-Ruiz, Ramon [1 ,3 ]
Ortiz Romero, Clemente [1 ]
Valli, Enrico [2 ,11 ]
Brereton, Paul
Koidis, Anastasios
Korytkowska, Martyna [4 ]
Servili, Maurizio [5 ]
Selvaggini, Roberto [5 ]
Lacoste, Florence [6 ]
Escobessa, Julien [6 ]
Vichi, Stefania [7 ]
Quintanilla-Casas, Beatriz [7 ]
Tres, Alba [7 ]
Golay, Pierre-Alain [8 ]
Lucci, Paolo [9 ]
Moret, Erica [10 ]
Bendini, Alessandra [2 ]
Gallina Toschi, Tullia [2 ]
机构
[1] Inst Grasa CSIC, Seville, Spain
[2] Univ Bologna, Dept Agr & Food Sci, Alma Mater Studiorum, Bologna, Italy
[3] Univ Seville, Dept Analyt Chem, E-41012 Seville, Spain
[4] Queens Univ Belfast, Inst Global Food Secur, Belfast, Antrim, North Ireland
[5] Univ Perugia, Dept Agr Food & Environm Sci, Perugia, Italy
[6] Inst Corps Gras ITERG, Canejan, France
[7] Univ Barcelona, Dept Nutr Ciencies Alimentacio & Gastron, Campus Alimentacio Torribera, Santa Coloma De Gramenet, Spain
[8] Nestle Res Ctr, Lausanne, Switzerland
[9] Univ Politecn Marche, Dept Agr Food & Environm Sci, Ancona, Italy
[10] Univ Udine, Dept Agrifood Environm & Anim Sci, Udine, Italy
[11] Piazza Goidanich 60, I-47521 Cesena, FC, Italy
关键词
collaborative trial validation; sensory analysis; SPME-GC-FID/MS; virgin olive oil; volatile compounds;
D O I
10.1002/ejlt.202300079
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The organoleptic assessment (Panel test) is the only procedure within the official methods for determining the quality of virgin olive oils that involves an expert panel. There is an urgent need for analytical methodology that can reliably measure volatile compounds in virgin olive oils that is capable of supporting and anticipating the official Panel test. For this reason, a new method based on solid-phase microextraction-gas chromatography with the choice of two possible detectors (FID or MS) was subjected to a large international interlaboratory validation study. The study involved a two-stage process: first, a pretrial phase in which 7 participants were exposed to the method for the first time to identify any initial problems with the methodology; then, a formal validation stage (trial proper), which involved 20 laboratories from Europe, USA, Japan and China. The performance of the different detectors was investigated. While both methods have advantages, the method using FID provided better results for 11 compounds, in terms of reproducibility, compared to MS. This information will allow to implement the method with accurate information of the method performance depending on the detector used.Practical applications: This study provides information from an interlaboratory validation of a method for measuring volatile compounds in virgin olive oils conducted with laboratories (from industry and academia) working in the olive oil sector. The information on the expected analytical errors in the determination of each volatile compound is necessary to apply this method for supporting the official Panel test (sensory analysis). The SPME-GC-MS/FID methods proposed in this work can be used for the internal quality control of a company/distributor/quality control laboratory and could also be used in cases of difficult/contradictory organoleptic assessment, or to confirm results from sensory panels in cases of disputes/disagreement (Reg. EU 2022/2105). International interlaboratory validation strategy of a multianalyte analysis of volatile compounds in virgin olive oils using two SPME-GC-FID/MS methods.image
引用
收藏
页数:13
相关论文
共 50 条
  • [11] Variability in volatile compounds from lipoxygenase pathway in extra virgin olive oils from Tuscan olive germoplasm by quantitative SPME/GC-MS
    Aprea, Eugenio
    Gasperi, Flavia
    Betta, Emanuela
    Sani, Graziano
    Cantini, Claudio
    JOURNAL OF MASS SPECTROMETRY, 2018, 53 (09): : 824 - 832
  • [12] Determination of volatile organic compounds in human breath for Helicobacter pylori detection by SPME-GC/MS
    Ulanowska, Agnieszka
    Kowalkowski, Tomasz
    Hrynkiewicz, Katarzyna
    Jackowski, Marek
    Buszewski, Boguslaw
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (03) : 391 - 397
  • [13] A Peer Inter-laboratory Study of SPME-GC-FID/MS Method for the Analysis of Volatile Compounds in Virgin Olive Oils for Supporting Panel Test: Extracted Conclusions and Future Directions.
    Wang, Chairs Selina
    Cercaci, Luisito
    Garcia Gonzalez, Diego Luis
    Casadei, Enrico
    Valli, Enrico
    Aparicio-Ruiz, Ramon
    Ortiz Romero, Clemente
    Servili, Maurizio
    Selvaggini, Roberto
    Lacoste, Florence
    Escobessa, Julien
    Vichi, Stefania
    Quintanilla-Casas, Beatriz
    Golay, Pierre-Alain
    Lucci, Paolo
    Moret, Erica
    Bendini, Alessandra
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2021, 98 : 12 - 13
  • [14] Profiling of Volatile Compounds in Beef, Rat, and Wild Boar Meat using SPME-GC/MS
    Amalia, Lia
    Kusnandar, Feri
    Yuliana, Nancy Dewi
    Sugita, Purwantiningsih
    SAINS MALAYSIANA, 2022, 51 (09): : 2897 - 2911
  • [15] Identification of volatile organic compounds present in decaying chicken organs using SPME-GC/MS
    Flotteron, Amanda
    Lewis, Taylor
    Sabo, Mark
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [16] Characterisation of volatile compounds associated to sensory changes during the storage of traditional sorghum beer by HS-GC/FID and SPME-GC/MS
    Attchelouwa, Constant K.
    N'guessan, Florent K.
    Marcotte, Stephane
    Amoikon, Tiemele L. S.
    Charmel, Melissa
    Dje, Marcellin K.
    JOURNAL OF AGRICULTURE AND FOOD RESEARCH, 2020, 2
  • [17] IN-HOUSE VALIDATION OF AN SPE-GC-FID METHOD FOR THE DETECTION OF FREE AND ESTERIFIED HYDROXYLATED MINOR COMPOUNDS IN VIRGIN OLIVE OILS
    Valli, Enrico
    Milani, Andrea
    Srbinovska, Ana
    Moret, Erica
    Moret, Sabrina
    Bendini, Alessandra
    Moreda, Wenceslao
    Gallina Toschi, Tullia
    Lucci, Paolo
    RIVISTA ITALIANA DELLE SOSTANZE GRASSE, 2021, 98 (04): : 300 - 301
  • [18] In-House Validation of an SPE-GC-FID Method for the Detection of Free and Esterified Hydroxylated Minor Compounds in Virgin Olive Oils
    Valli, Enrico
    Milani, Andrea
    Srbinovska, Ana
    Moret, Erica
    Moret, Sabrina
    Bendini, Alessandra
    Moreda, Wenceslao
    Toschi, Tullia Gallina
    Lucci, Paolo
    FOODS, 2021, 10 (06)
  • [19] Determination of volatile organic compounds in headspace above saliva specimens using SPME-GC/MS technique
    Milanowski, Maciej
    Rudnicka, Joanna
    Ligor, Tomasz
    Buszewski, Boguslaw
    PROCEEDINGS OF THE 14TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY, 2018, : 1 - 6
  • [20] Volatile profiles of Italian monovarietal extra virgin olive oils via HS-SPME-GC-MS: Newly identified compounds, flavors molecular
    Cecchi, Teresa
    Alfei, Barbara
    FOOD CHEMISTRY, 2013, 141 (03) : 2025 - 2035