Thermal-hydraulic assessment of Once-Through Steam Generators for EU-DEMO WCLL Breeding Blanket primary cooling system application

被引:7
|
作者
Ciurluini, C. [1 ]
Vannoni, Alessandra [1 ]
Del Moro, Tommaso [1 ]
Lorusso, Pierdomenico [2 ]
Tincani, Amelia [3 ]
Del Nevo, Alessandro [3 ]
Barucca, Luciana [4 ]
Giannetti, Fabio [1 ]
机构
[1] Sapienza Univ Rome, DIAEE, Corso Vittorio Emanuele II 244, I-00186 Rome, Italy
[2] ENEA, Dept Fus & Nucl Safety Technol, I-00044 Rome, Italy
[3] ENEA Dept Fus & Nucl Safety Technol, I-40032 Camugnano, BO, Italy
[4] Ansaldo Nucl, Via N Lorenzi 8, I-16152 Genoa, Italy
关键词
OTSG; PHTS; RELAP5; Transient analysis; Balance of Plant; STEAM;
D O I
10.1016/j.fusengdes.2023.113688
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Once-Through Steam Generators (OTSGs) were recently selected to be installed in the Primary Heat Transfer Systems (PHTS) related to EU-DEMO WCLL Breeding Blanket (BB). Referring to the Balance of Plant Direct Coupling Design (BoP-DCD) option, these components are used to deliver the thermal power removed from the two principal blanket subsystems, i.e. First Wall (FW) and Breeder Zone (BZ), to the Power Conversion System (PCS). OTSG design foresees a vertical component with primary water moving downward inside tube bundle and secondary fluid flowing throughout shell in counter current. The latter moves firstly downwards through the annular downcomer and then goes up in the central riser, where it boils up to super-heated steam conditions. Then, it is deflected by the upper tubesheet, flows again downwards along the steam downcomer and exits through the laterally connected steam nozzles. In the last years, as part of the research activities associated to the Work Package Balance of Plant (WPBoP), a detailed analysis of the steam generator, aimed at deeply understanding the main thermal-hydraulic aspects characterizing its performances during the pulsed regime of DEMO normal operations, was performed. To fulfil this scope, a complete model of the component was prepared by using the best-estimate system code RELAP5/ MOD3.3, selected to be also the reference design verification tool. During operations, OTSG experiences full-load and low-load alternative phases with rapid transitions from one another. The steam generator capability to follow such load variations avoiding the occurrence of instabilities in the component was studied. The computational activity carried out was a preliminary thermal-hydraulic char-acterization of the component conceptual design during both pulse and dwell phases. The feedbacks of this analysis were also fundamental for the conceptualization of the steam generator mock-up to be installed in the planned STEAM facility that will be built at the ENEA Research center of Brasimone.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Development of a computer code, ONCESG, for the thermal-hydraulic design of a Once-Through Steam Generator
    Yoon, J
    Kim, JP
    Kim, HY
    Lee, DJ
    Chang, MH
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2000, 37 (05) : 445 - 454
  • [22] Study on the systematic thermal-hydraulic characteristics of helical coil once-through steam generator
    Yao, Hao
    Chen, Guo
    Lu, Kailin
    Wu, Yingwei
    Tian, Wenxi
    Su, Guanghui
    Qiu, Suizheng
    Annals of Nuclear Energy, 2021, 154
  • [23] Study on the systematic thermal-hydraulic characteristics of helical coil once-through steam generator
    Yao, Hao
    Chen, Guo
    Lu, Kailin
    Wu, Yingwei
    Tian, Wenxi
    Su, Guanghui
    Qiu, Suizheng
    ANNALS OF NUCLEAR ENERGY, 2021, 154
  • [24] Thermal-hydraulic analysis code development for sodium heated once-through steam generator
    Xu, Rongshuan
    Zhang, Dalin
    Tian, Wenxi
    Qiu, Suizheng
    Su, G. H.
    ANNALS OF NUCLEAR ENERGY, 2019, 127 : 385 - 394
  • [25] Thermal-hydraulic analysis of once-through steam generator with annular narrow slot tube
    Han, Jinyu
    He, Wen
    Liu, Yao
    Zhao, Chenru
    Bo, Hanliang
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [26] RELAP5-based thermal-hydraulic assessment of the STEAM facility for DEMO WCLL balance of plant analysis
    Vannoni, Alessandra
    Lorusso, Pierdomenico
    Eboli, Marica
    Giannetti, Fabio
    Ciurluini, Cristiano
    Sierra, Diego Jaramillo
    Del Nevo, Alessandro
    FUSION ENGINEERING AND DESIGN, 2024, 202
  • [27] Selection of EU-DEMO divertor operating conditions: water cooling thermal-hydraulic parameters and power exhaust capabilities
    Marzullo, D.
    Spagnuolo, G. A.
    Aiello, G.
    Boscary, J.
    Graziosi, G.
    Moscato, I.
    Quartararo, A.
    You, J. H.
    FUSION ENGINEERING AND DESIGN, 2024, 203
  • [28] Thermal-Hydraulic Performance Analysis and Tube Inlet Orifice Design of a Once-Through Steam Generator
    Han, Hun Sik
    Kim, Young In
    Bae, Youngmin
    Kim, Sang Ji
    HEAT TRANSFER ENGINEERING, 2021, 43 (3-5) : 198 - 207
  • [29] Effects of rolling motion on helical coil once-through steam generator thermal-hydraulic characteristics
    Hou, Yandong
    Li, Jiangping
    Sun, Haoyu
    Li, Weichao
    Zhang, Chao
    Xiang, Yan
    ANNALS OF NUCLEAR ENERGY, 2023, 194
  • [30] Model for thermal-hydraulic analysis of once-through helical-coiled steam generator in LMFBRs
    Tsinghua Univ, Beijing, China
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 1997, 37 (02): : 35 - 38