Graphene Field Effect Biosensor for Concurrent and Specific Detection of SARS-CoV-2 and Influenza

被引:14
|
作者
Kumar, Neelotpala [1 ,2 ]
Towers, Dalton [3 ]
Myers, Samantha [4 ]
Galvin, Cooper [4 ]
Kireev, Dmitry [1 ,2 ,6 ]
Ellington, Andrew D. [5 ]
Akinwande, Deji [1 ,2 ]
机构
[1] Univ Texas Austin, Microelect Res Ctr, Austin, TX 78758 USA
[2] Univ Texas Austin, Dept Elect & Comp Engn, Austin, TX 78712 USA
[3] Univ Texas Austin, Dept Chem Engn, Austin, TX 78712 USA
[4] Univ Texas Austin, Coll Nat Sci, Austin, TX 78712 USA
[5] Univ Texas Austin, Inst Cellular & Mol Biol, Ctr Syst & Synthet Biol, Dept Mol Biosci, Austin, TX 78712 USA
[6] Univ Massachusetts Amherst, Dept Biomed Engn, Amherst, MA 01003 USA
基金
美国国家科学基金会;
关键词
Pandemic; Graphene FETs; Biosensors; COVID-19; SARS-CoV-2; Influenza; Immunology; RAPID DETECTION; TRANSISTOR; DESIGN;
D O I
10.1021/acsnano.3c07707
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The SARS-CoV-2 pandemic has highlighted the need for devices capable of carrying out rapid differential detection of viruses that may manifest similar physiological symptoms yet demand tailored treatment plans. Seasonal influenza may be exacerbated by COVID-19 infections, increasing the burden on healthcare systems. In this work, we demonstrate a technology based on liquid-gated graphene field-effect transistors (GFETs), for rapid and ultraprecise sensing and differentiation of influenza and SARS-CoV-2 surface protein. Most distinctively, the device consists of 4 onboard GFETs arranged in a quadruple architecture, where each quarter is functionalized individually (with either antibodies or chemically passivated control) but measured jointly. The sensor platform was tested against a range of concentrations of viral surface proteins from both viruses with the lowest tested and detected concentration at similar to 50 ag/mL, or 88 zM for COVID-19 and 227 zM for Flu, which is 5-fold lower than the values reported previously on a similar platform. Unlike the classic real-time polymerase chain reaction test, which has a turnaround time of a few hours, the graphene technology presents an ultrafast response time of similar to 10 s even in complex and clinically relevant media such as saliva. Thus, we have developed a multianalyte, highly sensitive, and fault-tolerant technology for rapid diagnostic of contemporary, emerging, and future pandemics.
引用
收藏
页码:18629 / 18640
页数:12
相关论文
共 50 条
  • [21] An electrochemical, fluorescent, and colorimetric triple-mode homogeneous biosensor for the simultaneous detection of influenza A, influenza B, and SARS-CoV-2
    Dong, Jinying
    Qi, Lihua
    Wu, Xiaoya
    Sun, Chongsi
    Hu, Qiushi
    Su, Yan
    Shao, Gaoxiang
    Zhang, Yue
    Meng, Fanwei
    Du, Yingxia
    Han, Gaoshang
    Liu, Jie
    Zhou, Lei
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 411
  • [22] An intramolecular FRET biosensor for the detection of SARS-CoV-2 in biological fluids
    Montepietra, Daniele
    Germelli, Lorenzo
    Marchetti, Laura
    Tozzini, Valentina
    Angeloni, Elisa
    Giacomelli, Chiara
    Storti, Barbara
    Bizzarri, Ranieri
    Barresi, Elisabetta
    Taliani, Sabrina
    Brancolini, Giorgia
    Da Pozzo, Eleonora
    NANOSCALE, 2025, 17 (14) : 8803 - 8815
  • [23] Increased lethality in influenza and SARS-CoV-2 coinfection is prevented by influenza immunity but not SARS-CoV-2 immunity
    Hagit Achdout
    Einat. B. Vitner
    Boaz Politi
    Sharon Melamed
    Yfat Yahalom-Ronen
    Hadas Tamir
    Noam Erez
    Roy Avraham
    Shay Weiss
    Lilach Cherry
    Erez Bar-Haim
    Efi Makdasi
    David Gur
    Moshe Aftalion
    Theodor Chitlaru
    Yaron Vagima
    Nir Paran
    Tomer Israely
    Nature Communications, 12
  • [24] Increased lethality in influenza and SARS-CoV-2 coinfection is prevented by influenza immunity but not SARS-CoV-2 immunity
    Achdout, Hagit
    Vitner, Einat. B.
    Politi, Boaz
    Melamed, Sharon
    Yahalom-Ronen, Yfat
    Tamir, Hadas
    Erez, Noam
    Avraham, Roy
    Weiss, Shay
    Cherry, Lilach
    Bar-Haim, Erez
    Makdasi, Efi
    Gur, David
    Aftalion, Moshe
    Chitlaru, Theodor
    Vagima, Yaron
    Paran, Nir
    Israely, Tomer
    NATURE COMMUNICATIONS, 2021, 12 (01)
  • [25] A Dielectric Modulated Biosensor for SARS-CoV-2
    Yadav, Shivendra
    Gedam, Anju
    Tirkey, Sukeshni
    IEEE SENSORS JOURNAL, 2021, 21 (13) : 14483 - 14490
  • [26] Comparing SARS-CoV-2 with SARS-CoV and influenza pandemics
    Standl, Fabian
    Joeckel, Karl-Heinz
    Brune, Bastian
    Schmidt, Boerge
    Stang, Andreas
    LANCET INFECTIOUS DISEASES, 2021, 21 (04): : E77 - E77
  • [27] Comparing SARS-CoV-2 with SARS-CoV and influenza pandemics
    Petersen, Eskild
    Koopmans, Marion
    Go, Unyeong
    Hamer, Davidson H.
    Petrosillo, Nicola
    Castelli, Francesco
    Storgaard, Merete
    Al Khalili, Sulien
    Simonsen, Lone
    LANCET INFECTIOUS DISEASES, 2020, 20 (09): : E238 - E244
  • [28] Great enhancement of sensitivity for SARS-CoV-2 detection by integrated graphene FET biosensor using ζ potential modulator
    Yamamoto, Kaori
    Sato, Natsuki
    Sakano, Kiyoji
    Yano, Mamiko
    Ohnishi, Eriko
    Ono, Takao
    Kanai, Yasushi
    Ushiba, Shota
    Miyakawa, Naruto
    Tani, Shinsuke
    Kimura, Masahiko
    Watanabe, Yohei
    Inoue, Koichi
    Tanaka, Hidekazu
    Matsumoto, Kazuhiko
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2024, 63 (03)
  • [29] Rapid detection of SARS-CoV-2 using graphene-based IoT integrated advanced electrochemical biosensor
    Sadique, Mohd. Abubakar
    Yadav, Shalu
    Ranjan, Pushpesh
    Khan, Mohd. Akram
    Kumar, Ashok
    Khan, Raju
    MATERIALS LETTERS, 2021, 305
  • [30] Ultrasensitive Detection of Dopamine, IL-6 and SARS-CoV-2 Proteins on Crumpled Graphene FET Biosensor
    Hwang, Michael Taeyoung
    Park, Insu
    Heiranian, Mohammad
    Taqieddin, Amir
    You, Seungyong
    Faramarzi, Vahid
    Pak, Angela A.
    Zande, Arend M.
    Aluru, Narayana R.
    Bashir, Rashid
    ADVANCED MATERIALS TECHNOLOGIES, 2021, 6 (11)