Graphene Field Effect Biosensor for Concurrent and Specific Detection of SARS-CoV-2 and Influenza

被引:14
|
作者
Kumar, Neelotpala [1 ,2 ]
Towers, Dalton [3 ]
Myers, Samantha [4 ]
Galvin, Cooper [4 ]
Kireev, Dmitry [1 ,2 ,6 ]
Ellington, Andrew D. [5 ]
Akinwande, Deji [1 ,2 ]
机构
[1] Univ Texas Austin, Microelect Res Ctr, Austin, TX 78758 USA
[2] Univ Texas Austin, Dept Elect & Comp Engn, Austin, TX 78712 USA
[3] Univ Texas Austin, Dept Chem Engn, Austin, TX 78712 USA
[4] Univ Texas Austin, Coll Nat Sci, Austin, TX 78712 USA
[5] Univ Texas Austin, Inst Cellular & Mol Biol, Ctr Syst & Synthet Biol, Dept Mol Biosci, Austin, TX 78712 USA
[6] Univ Massachusetts Amherst, Dept Biomed Engn, Amherst, MA 01003 USA
基金
美国国家科学基金会;
关键词
Pandemic; Graphene FETs; Biosensors; COVID-19; SARS-CoV-2; Influenza; Immunology; RAPID DETECTION; TRANSISTOR; DESIGN;
D O I
10.1021/acsnano.3c07707
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The SARS-CoV-2 pandemic has highlighted the need for devices capable of carrying out rapid differential detection of viruses that may manifest similar physiological symptoms yet demand tailored treatment plans. Seasonal influenza may be exacerbated by COVID-19 infections, increasing the burden on healthcare systems. In this work, we demonstrate a technology based on liquid-gated graphene field-effect transistors (GFETs), for rapid and ultraprecise sensing and differentiation of influenza and SARS-CoV-2 surface protein. Most distinctively, the device consists of 4 onboard GFETs arranged in a quadruple architecture, where each quarter is functionalized individually (with either antibodies or chemically passivated control) but measured jointly. The sensor platform was tested against a range of concentrations of viral surface proteins from both viruses with the lowest tested and detected concentration at similar to 50 ag/mL, or 88 zM for COVID-19 and 227 zM for Flu, which is 5-fold lower than the values reported previously on a similar platform. Unlike the classic real-time polymerase chain reaction test, which has a turnaround time of a few hours, the graphene technology presents an ultrafast response time of similar to 10 s even in complex and clinically relevant media such as saliva. Thus, we have developed a multianalyte, highly sensitive, and fault-tolerant technology for rapid diagnostic of contemporary, emerging, and future pandemics.
引用
收藏
页码:18629 / 18640
页数:12
相关论文
共 50 条
  • [1] Detection of SARS-CoV-2 Virus Amplification Using a Crumpled Graphene Field-Effect Transistor Biosensor
    Park, Insu
    Lim, Jongwon
    You, Seungyong
    Hwang, Michael Taeyoung
    Kwon, Jaehong
    Koprowski, Katherine
    Kim, Sungdae
    Heredia, John
    de Ramirez, Sarah A. Stewart
    Valera, Enrique
    Bashir, Rashid
    ACS SENSORS, 2021, 6 (12): : 4461 - 4470
  • [2] Design and Development of Graphene FET Biosensor for the Detection of SARS-CoV-2
    Krsihna, B. Vamsi
    Ahmadsaidulu, Shaik
    Teja, Surapaneni Sai Tarun
    Jayanthi, D.
    Navaneetha, Alluri
    Reddy, P. Rahul
    Prakash, M. Durga
    SILICON, 2022, 14 (11) : 5913 - 5921
  • [3] Graphene-metasurface-based biosensor for SARS-CoV-2 detection
    Ghosh, Sambit Kumar
    Chaudhuri, Anirban
    Bhattacharyya, Somak
    Pal, Parama
    HIGH CONTRAST METASTRUCTURES XI, 2022, 12011
  • [4] Design and Development of Graphene FET Biosensor for the Detection of SARS-CoV-2
    B. Vamsi Krsihna
    Shaik Ahmadsaidulu
    Surapaneni Sai Tarun Teja
    D. Jayanthi
    Alluri Navaneetha
    P. Rahul Reddy
    M. Durga Prakash
    Silicon, 2022, 14 : 5913 - 5921
  • [5] Cost-Effective Modular Biosensor for SARS-CoV-2 and Influenza A Detection
    Murray, Andrew
    Ojeda, Julio
    El Merhebi, Omar
    Calvo-Marzal, Percy
    Gerasimova, Yulia
    Chumbimuni-Torres, Karin
    BIOSENSORS-BASEL, 2023, 13 (09):
  • [6] Ultrasensitive Detection of SARS-CoV-2 Antibody by Graphene Field-Effect Transistors
    Kang, Hua
    Wang, Xuejun
    Guo, Mingquan
    Dai, Changhao
    Chen, Renzhong
    Yang, Lei
    Wu, Yanling
    Ying, Tianlei
    Zhu, Zhaoqin
    Wei, Dapeng
    Liu, Yunqi
    Wei, Dacheng
    NANO LETTERS, 2021, 21 (19) : 7897 - 7904
  • [7] MXene-Graphene Field-Effect Transistor Sensing of Influenza Virus and SARS-CoV-2
    Li, Yanxiao
    Peng, Zhekun
    Holl, Natalie J.
    Hassan, Md Rifat
    Pappas, John M.
    Wei, Congjie
    Izadi, Omid Hoseini
    Wang, Yang
    Dong, Xiangyang
    Wang, Cheng
    Huang, Yue-Wern
    Kim, DongHyun
    Wu, Chenglin
    ACS OMEGA, 2021, 6 (10): : 6643 - 6653
  • [8] Ultrasensitive detection of SARS-CoV-2 spike protein by graphene field-effect transistors
    Silvestri, Alessandro
    Zayas-Arrabal, Julian
    Vera-Hidalgo, Mariano
    Di Silvio, Desire
    Wetzl, Cecilia
    Martinez-Moro, Marta
    Zurutuza, Amaia
    Torres, Elias
    Centeno, Alba
    Maestre, Arantxa
    Manuel Gomez, Juan
    Arrastua, Maria
    Elicegui, Marta
    Ontoso, Nerea
    Prato, Maurizio
    Coluzza, Ivan
    Criado, Alejandro
    NANOSCALE, 2023, 15 (03) : 1076 - 1085
  • [9] Portable microfluidic impedance biosensor for SARS-CoV-2 detection
    Laleh, Soroush
    Ibarlucea, Bergoi
    Stadtmueller, Marlena
    Cuniberti, Gianaurelio
    Medina-Sanchez, Mariana
    BIOSENSORS & BIOELECTRONICS, 2023, 236
  • [10] A review of electrochemical biosensor application in the detection of the SARS-COV-2
    Jiang, Chunying
    Mu, Xihui
    Du, Bin
    Tong, Zhaoyang
    MICRO & NANO LETTERS, 2022, 17 (03) : 49 - 58