An image-based metal artifact reduction technique utilizing forward projection in computed tomography

被引:0
|
作者
Ichikawa, Katsuhiro [1 ]
Kawashima, Hiroki [1 ]
Takata, Tadanori [2 ]
机构
[1] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, 5-11-80 Kodatsuno, Kanazawa 9200942, Japan
[2] Kanazawa Univ Hosp, Dept Diagnost Radiol, 13-1 Takara Machi, Kanazawa 9208641, Japan
关键词
Computed tomography; Metal artifact; Forward projection; Projection data; Parallel computation; RECONSTRUCTION;
D O I
10.1007/s12194-024-00790-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The projection data generated via the forward projection of a computed tomography (CT) image (FP-data) have useful potentials in cases where only image data are available. However, there is a question of whether the FP-data generated from an image severely corrupted by metal artifacts can be used for the metal artifact reduction (MAR). The aim of this study was to investigate the feasibility of a MAR technique using FP-data by comparing its performance with that of a conventional robust MAR using projection data normalization (NMARconv). The NMAR(conv) was modified to make use of FP-data (FPNMAR). A graphics processing unit was used to reduce the time required to generate FP-data and subsequent processes. The performances of FPNMAR and NMAR(conv) were quantitatively compared using a normalized artifact index (AI(n)) for two cases each of hip prosthesis and dental fillings. Several clinical CT images with metal artifacts were processed by FPNMAR. The AI(n) values of FPNMAR and NMAR(conv) were not significantly different from each other, showing almost the same performance between these two techniques. For all the clinical cases tested, FPNMAR significantly reduced the metal artifacts; thereby, the images of the soft tissues and bones obscured by the artifacts were notably recovered. The computation time per image was similar to 56 ms. FPNMAR, which can be applied to CT images without accessing the projection data, exhibited almost the same performance as that of NMAR(conv), while consuming significantly shorter processing time. This capability testifies the potential of FPNMAR for wider use in clinical settings.
引用
收藏
页码:402 / 411
页数:10
相关论文
共 50 条
  • [21] Normalized Metal Artifact Reduction in Head and Neck Computed Tomography
    Lell, Michael M.
    Meyer, Esther
    Kuefner, Michael A.
    May, Matthias S.
    Raupach, Rainer
    Uder, Michael
    Kachelriess, Marc
    INVESTIGATIVE RADIOLOGY, 2012, 47 (07) : 415 - 421
  • [22] Projection-Based Metal-Artifact Reduction for Industrial 3D X-ray Computed Tomography
    Amirkhanov, Artem
    Heinzl, Christoph
    Reiter, Michael
    Kastner, Johann
    Groeller, M. Eduard
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2011, 17 (12) : 2193 - 2202
  • [23] Adaptive Normalized Metal Artifact Reduction (ANMAR) in Computed Tomography
    Meyer, Esther
    Raupach, Rainer
    Schmidt, Bernhard
    Mahnken, Andreas H.
    Kachelriess, Marc
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2560 - 2565
  • [24] Dual-energy-based metal segmentation for metal artifact reduction in dental computed tomography
    Hegazy, Mohamed A. A.
    Eldib, Mohamed Elsayed
    Hernandez, Daniel
    Cho, Myung Hye
    Cho, Min Hyoung
    Lee, Soo Yeol
    MEDICAL PHYSICS, 2018, 45 (02) : 714 - 724
  • [25] Image-Based Coronary Calcium and Metal Subtraction in Coronary Computed Tomography Angiography
    So, Aaron
    Chang, Chun-Bi
    Hsieh, I-Chang
    Wen, Ming-Shien
    Lee, Ting-Yim
    Shieh, Yao
    Chen, Chun-Chi
    Wan, Yung-Liang
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (08) : 1780 - 1788
  • [26] Image quality comparison of a nonlinear image-based noise reduction technique with a hybrid-type iterative reconstruction for pediatric computed tomography
    Watanabe, Shota
    Ichikawa, Katsuhiro
    Kawashima, Hiroki
    Kono, Yuki
    Kosaka, Hiroyuki
    Yamada, Koji
    Ishii, Kazunari
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 100 - 108
  • [27] Metal artifact reduction in computed tomography using local models in an image block-iterative scheme
    Van Slambrouck, Katrien
    Nuyts, Johan
    MEDICAL PHYSICS, 2012, 39 (11) : 7080 - 7093
  • [28] Streak Metal Artifact Reduction Technique in Cone Beam Computed Tomography Images after Endovascular Neurosurgery
    Otsuka, Takafumi
    Nishihori, Masahiro
    Izumi, Takashi
    Uemura, Takeshi
    Sakai, Takashi
    Nakano, Mizuki
    Kato, Naoki
    Kanamori, Fumiaki
    Tsukada, Tetsuya
    Uda, Kenji
    Yokoyama, Kinya
    Araki, Yoshio
    Saito, Ryuta
    NEUROLOGIA MEDICO-CHIRURGICA, 2021, 61 (08) : 468 - 474
  • [29] Image-Based Noise Reduction for Material Decomposition in Dual or Multi Energy Computed Tomography
    Ozdemir, Mahmut
    Dorn, Sabrina
    Pisana, Francesco
    Uhrig, Monika
    Schlemmer, Heinz-Peter
    Kachelriess, Marc
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [30] Metal artifact reduction for intracranial projectiles on post mortem computed tomography
    Douis, N.
    Formery, A. S.
    Hossu, G.
    Martrille, L.
    Kolopp, M.
    Teixeira, P. A. Gondim
    Blum, A.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2020, 101 (03) : 177 - 185