Validity and reliability of measurement of peripheral oxygen saturation during the 6-Minute Walk Test in patients with systemic sclerosis

被引:0
|
作者
Elkjaer, Amanda Lynggaard [1 ]
Naeser, Esben Uggerby [1 ,3 ]
Aaen, Katja Thorup [1 ]
Hovgaard, Henrik Lynge [2 ]
Juhl-Olsen, Peter [2 ,3 ]
Bendstrup, Elisabeth [3 ,4 ]
Sondergaard, Klaus [1 ,3 ]
机构
[1] Aarhus Univ Hosp, Dept Rheumatol, Palle Juul Jensens Blvd 59, DK-8200 Aarhus N, Denmark
[2] Aarhus Univ Hosp, Dept Anaesthesiol & Intens Care, Palle Juul Jensens Blvd 99, DK-8200 Aarhus N, Denmark
[3] Aarhus Univ, Dept Clin Med, Palle Juul Jensens Blvd 91, DK-8200 Aarhus N, Denmark
[4] Aarhus Univ Hosp, Dept Resp Dis & Allergy, Palle Juul Jensens,Blvd 99, DK-8200 Aarhus N, Denmark
关键词
Reproducibility of Results; Oximetry; Walk Test; Scleroderma; Systemic; EULAR SCLERODERMA TRIALS; PULSE OXIMETRY; GUIDELINES; STATEMENT;
D O I
10.1007/s00296-024-05532-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Peripheral oxygen saturation (SpO2) using the fingers may have important limitations due to Raynaud's phenomenon and sclerodactyly in patients with systemic sclerosis (SSc). Sensors located at more central body positions may be more accurate as these as less prone to Raynaud attacks. To determine the validity and reliability of the SpO2 measured at the finger, forehead, and earlobe during the 6-Minute Walk Test (6MWT). Eighty two patients with SSc had an arterial line placed while performing the 6MWT. Peripheral oxygen saturation was simultaneously measured by finger, forehead, and earlobe sensors and compared to the arterial oxygen saturation (SaO2) measured before and after the 6MWT. 40 patients repeated the 6MWT one week later to determine re-test reliability. We used Bland-Altman plots to display the agreement between SpO2 and SaO2. The intraclass correlation coefficient for repeated measurement of minimum SpO2 was calculated. The mean difference between SpO2 and SaO2 after the 6MWT was - 3% (SD: +/- 5), 0% (SD: +/- 2), and 1% (SD: +/- 2) for the finger, forehead, and earlobe, respectively. The minimum SpO2 measured at the finger demonstrated the poorest re-test reliability: The ICC (95% CI) showed good agreement using the ear and forehead probe (ICCear = 0.89 [95% CI 0.80; 0.94]; ICCforehead = 0.77 [95% CI 0.60; 0.87]), while a modest reliability was found using the finger probe (ICCfinger = 0.65 95% CI [0.43; 0.80]). SpO2 should be measured using either the earlobe or forehead during the 6MWT in patients with SSc. Clinical Trials.Gov (NCT04650659).
引用
收藏
页码:611 / 620
页数:10
相关论文
共 50 条
  • [21] Exercise Intensity during 6-Minute Walk Test in Patients with Peripheral Artery Disease
    Farah, Breno Quintella
    Ritti-Dias, Raphael Mendes
    Montgomery, Polly
    Cucato, Gabriel Grizzo
    Gardner, Andrew
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2020, 114 (03) : 486 - 491
  • [22] Decrease in Cerebral Oxygen Saturation During the 6-Minute Walk Test in Pediatric Pulmonary Arterial Hypertension
    Orgun, Leman Tekin
    Ozturk, Zeynep
    Canbeyli, Fatma Hayvaci
    Yapar, Dilek
    Gucuyener, Kivilcim
    Kula, Serdar
    PEDIATRIC CARDIOLOGY, 2019, 40 (07) : 1494 - 1502
  • [23] The Reliability of 6-Minute Walk Test to Predict Peak Oxygen Uptake in Patients with Pulmonary Hypertension
    Fujino, Takeo
    Hatano, Masaru
    Yao, Atsushi
    Nitta, Daisuke
    Muraoka, Hironori
    Minatsuki, Shun
    Imamura, Teruhiko
    Inaba, Toshiro
    Maki, Hisataka
    Kinugawa, Koichiro
    Komuro, Issei
    JOURNAL OF CARDIAC FAILURE, 2014, 20 (08) : S74 - S74
  • [24] Reliability of the 6-minute walk test in patients referred for pulmonary rehabilitation
    van der Schoot, H. J. M.
    van Ranst, D.
    Otten, H. J.
    Stoop, W. A.
    van de Port, I. G.
    Meijer, J. W.
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [25] Should oxyhaemoglobin saturation be monitored continuously during the 6-minute walk test?
    Fiore, C. B.
    Lee, A. L.
    McDonald, C. F.
    Hill, C. J.
    Holland, A. E.
    CHRONIC RESPIRATORY DISEASE, 2011, 8 (03) : 181 - 184
  • [26] Decrease in Cerebral Oxygen Saturation During the 6-Minute Walk Test in Pediatric Pulmonary Arterial Hypertension
    Leman Tekin Orgun
    Zeynep Öztürk
    Fatma Hayvacı Canbeyli
    Dilek Yapar
    Kıvılcım Gücüyener
    Serdar Kula
    Pediatric Cardiology, 2019, 40 : 1494 - 1502
  • [27] Reliability, construct validity and determinants of 6-minute walk distance in patients with asthma
    Meys, Roy
    Janssen, Steffi
    Franssen, Frits
    Vaes, Anouk
    Stoffels, Anouk
    Van Hees, Hieronymus
    Van Den Borst, Bram
    Klijn, Peter
    Burtin, Chris
    Hul, Alex Van 'T
    Spruit, Martijn
    EUROPEAN RESPIRATORY JOURNAL, 2021, 58
  • [28] Reliability, construct validity and determinants of 6-minute walk test performance in patients with chronic heart failure
    Uszko-Lencer, Nicole H. M. K.
    Mesquita, Rafael
    Janssen, Eefje
    Werter, Christ
    Rocca, Hans-Peter Brunner-La
    Pitta, Fabio
    Wouters, Emiel F. M.
    Spruit, Martijn A.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 240 : 285 - 290
  • [29] Validity of the 6-Minute Walk Test and YMCA Submaximal Cycle Test During Midpregnancy
    Tinius, Rachel A.
    Blankenship, Maire
    Maples, Jill M.
    Pitts, Bailey C.
    Furgal, Karen
    Norris, Elizabeth S.
    Hoover, Donald L.
    Olenick, Alyssa
    Lambert, Joshua
    Cade, William Todd
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2021, 35 (11) : 3236 - 3242
  • [30] The reliability and validity of a 6-minute walk test as a measure of physical endurance in older adults
    Rikli, RE
    Jones, CJ
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 1998, 6 (04) : 363 - 375