A Low-Temperature Processed Organic Hole-Blocking Contact Layer for Amorphous Selenium X-Ray Photoconductor

被引:0
|
作者
Adnani, Sahar [1 ]
Pil-Ali, Abdollah
Karim, Karim S.
机构
[1] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Amorphous selenium (a-Se); X-ray detectors; hole-blocking layers; SU-8;
D O I
10.1109/LED.2023.3296332
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Amorphous selenium (a-Se) X-ray detectors have been used commercially for two decades in mammography because of their high spatial resolution. However, these devices face challenges in high spatial resolution tomography and angiography where lower radiation exposures and dynamic imaging are required. Higher voltages across the selenium layer can potentially improve sensitivity and temporal performance, but dark current is a concern. Although organic polyimide (PI) layers were previously demonstrated to have excellent hole-blocking properties that enabled high voltage mode operation with selenium devices, their higher baking and curing temperatures have restricted usage on the top surface of temperature-sensitive selenium as a hole-blocking layer. In this study, we explore low-temperature SU-8 as a hole-blocking layer for selenium. Our findings reveal that the devices with SU-8 as a hole-blocking layer in either top or bottom configurations maintained a dark current below 1 pA/mm(2) even at an increased electric field of 40 V/mu m. Devices with the SU-8 hole-blocking layer at the top surface exhibited a sensitivity loss of 18% after exposure to a cumulative 0.175 Gray (Gy) X-ray while maintaining lag or persistent photoconductivity below 1% at 20 V/mu m. As a comparison, devices fabricated in the same run that utilized the previously reported PI hole-blocking layer at the bottom surface resulted in a sensitivity drop of 24.1% and with lag of approximate to 3.1%. These results indicate that higher-performance selenium detectors are achievable with SU-8 blocking layers and can expedite the commercial development of low-lag, high-gain selenium X-ray detectors for dynamic medical imaging.
引用
收藏
页码:1528 / 1530
页数:3
相关论文
共 50 条
  • [11] A LOW-TEMPERATURE X-RAY CAMERA
    OWEN, EA
    WILLIAMS, GI
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1954, 31 (02): : 49 - 54
  • [12] LOW-TEMPERATURE X-RAY ATTACHMENT
    DAVIS, GT
    EBY, RK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1975, 46 (09): : 1285 - 1286
  • [13] X-RAY PHOTOEMISSION SPECTRUM OF AMORPHOUS ANTIMONY PREPARED BY LOW-TEMPERATURE CONDENSATION
    ICHIKAWA, T
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1975, 14 (06) : 885 - 886
  • [14] Low-temperature, solution-processed molybdenum oxide hole-collection layer for organic photovoltaics
    Hammond, Scott R.
    Meyer, Jens
    Widjonarko, N. Edwin
    Ndione, Paul F.
    Sigdel, Ajaya K.
    Garcia, Andres
    Miedaner, Alexander
    Lloyd, Matthew T.
    Kahn, Antoine
    Ginley, David S.
    Berry, Joseph J.
    Olson, Dana C.
    JOURNAL OF MATERIALS CHEMISTRY, 2012, 22 (07) : 3249 - 3254
  • [15] Enhancing Temporal Performance of a-Se Detectors using a Low-temperature Hole-Blocking Bilayer Design
    Adnani, Sahar
    Pil-Ali, Abdollah
    Karim, Karim S.
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [16] LOW-TEMPERATURE ATTACHMENT TO X-RAY DIFFRACTOMETER
    PEROV, AP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1984, 27 (03) : 776 - 777
  • [17] LOW-TEMPERATURE X-RAY DIFFRACTION APPARATUS
    BOJKO, AA
    ACTA CRYSTALLOGRAPHICA, 1966, S 21 : A215 - &
  • [18] LOW-TEMPERATURE X-RAY CHAMBER FOR MONOCRYSTALS
    LYSAK, LI
    POLISHCH.YM
    VOVK, YN
    INDUSTRIAL LABORATORY, 1968, 34 (08): : 1228 - &
  • [19] A LOW-TEMPERATURE X-RAY POWDER CAMERA
    TOMBS, NC
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1952, 29 (11): : 364 - 364
  • [20] Low-temperature detectors in X-ray astronomy
    Porter, FS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 354 - 358