Accumulated biomechanical effects of mandibular molar mesialization using clear aligners with auxiliary devices: an iterative finite element analysis

被引:10
|
作者
Lyu, Xinwei [1 ,2 ,3 ]
Cao, Xing [1 ,2 ,3 ]
Chen, Luxian [1 ,2 ,3 ]
Liu, Yuyao [1 ,2 ,3 ]
Li, Huilin [1 ,2 ,3 ]
Hu, Cheng [1 ,2 ,3 ]
Tan, Jiali [1 ,2 ,3 ]
机构
[1] Sun Yat Sen Univ, Hosp Stomatol, Dept Orthodont, Guangzhou 510055, Peoples R China
[2] Sun Yat Sen Univ, Guangdong Prov Key Lab Stomatol, Guangzhou 510080, Peoples R China
[3] Sun Yat Sen Univ, Guanghua Sch Stomatol, Guangzhou 510080, Peoples R China
基金
中国国家自然科学基金;
关键词
Finite element analysis; Clear aligners; Numerical simulation; Molar mesialization; Long-term tooth movement; Biomechanics; ORTHODONTIC TOOTH MOVEMENT; PERMANENT 1ST MOLAR; PERIODONTAL-LIGAMENT; FORCE; PROTRACTION; RETRACTION; TORQUE; SPACE;
D O I
10.1186/s40510-023-00462-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThe biomechanics generated by the clear aligner (CA) material changes continuously during orthodontic tooth movement, but this factor remains unknown during the computer-aid design process and the predictability of molars movement is not as expected. Therefore, the purpose of this study was to propose an iterative finite element method to simulate the long-term biomechanical effects of mandibular molar mesialization (MM) in CA therapy under dual-mechanical systems.MethodsThree groups including CA alone, CA with a button, and CA with a modified lever arm (MLA) were created. Material properties of CA were obtained by in vitro mechanical experiments. MM was conducted by the rebound force exerted by CA material and the mesial elastic force (2N, 30 degrees to the occlusal plane) applied to the auxiliary devices. Stress intensity and distribution on periodontal ligament (PDL), attachment, button and MLA, and displacement of the second molar (M2) during the iterations were recorded.ResultsThere was a significant difference between the initial and cumulative long-term displacement. Specifically, compared to the beginning, the maximum stress of PDL decreased by 90% on average in the intermediate and final steps. The aligner was the main mechanical system at first, and then, the additional system exerted by the button and MLA dominated gradually. The stress of attachments and auxiliary devices is mainly concentrated on their interfaces with the tooth. Additionally, MLA provided a distal tipping and extrusive moment, which was the only group that manifested a total mesial displacement of the root.ConclusionsThe innovatively designed MLA was more effective in reducing undesigned mesial tipping and rotation of M2 than the traditional button and CA alone, which provided a therapeutic method for MM. The proposed iterative method simulated tooth movement by considering the mechanical characteristic of CA and its long-term mechanical force changes, which will facilitate better movement prediction and minimize the failure rate.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Biomechanical effects of different staging and attachment designs in maxillary molar distalization with clear aligner: a finite element study
    Gao, Jie
    Guo, Donghui
    Zhang, Xu
    Cheng, Yuxun
    Zhang, Hao
    Xu, Yuerong
    Jin, Zuolin
    Ma, Yanning
    PROGRESS IN ORTHODONTICS, 2023, 24 (01)
  • [32] Biomechanical effects of different staging and attachment designs in maxillary molar distalization with clear aligner: a finite element study
    Jie Gao
    Donghui Guo
    Xu Zhang
    Yuxun Cheng
    Hao Zhang
    Yuerong Xu
    Zuolin Jin
    Yanning Ma
    Progress in Orthodontics, 24
  • [33] The effects of lingual buttons, precision cuts, and patient-specific attachments during maxillary molar distalization with clear aligners: Comparison of finite element analysis
    Jia, Lurong
    Wang, Chunjuan
    Li, Lingjie
    He, Yao
    Wang, Chao
    Song, Jinlin
    Wang, Lizhen
    Fan, Yubo
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2023, 163 (01) : E1 - E12
  • [34] The Effect of Different Separated File Retrieval Strategies on the Biomechanical Behavior of a Mandibular Molar: A Finite Element Analysis Study
    Sira, Anas
    Nawar, Nawar Naguib
    Saber, Shehabeldin Mohamed
    Kim, Hyeon-Cheol
    JOURNAL OF ENDODONTICS, 2025, 51 (01) : 64 - 70
  • [35] Effects of upper arch expansion using clear aligners on different stride and torque: a three-dimensional finite element analysis
    Zhang, Yanqi
    Hui, Shuoyi
    Gui, Linyuan
    Jin, Fang
    BMC ORAL HEALTH, 2023, 23 (01)
  • [36] Effects of upper arch expansion using clear aligners on different stride and torque: a three-dimensional finite element analysis
    Yanqi Zhang
    Shuoyi Hui
    Linyuan Gui
    Fang Jin
    BMC Oral Health, 23
  • [37] Biomechanical analysis of effective mandibular en-masse retraction using Class II elastics with a clear aligner: a finite element study
    Wang, Qiuyu
    Dai, Danni
    Wang, Jianrong
    Chen, Yanfang
    Zhang, Chao
    PROGRESS IN ORTHODONTICS, 2022, 23 (01)
  • [38] Biomechanical analysis of effective mandibular en-masse retraction using Class II elastics with a clear aligner: a finite element study
    Qiuyu Wang
    Danni Dai
    Jianrong Wang
    Yanfang Chen
    Chao Zhang
    Progress in Orthodontics, 23
  • [39] Effective contribution ratio of the molar during sequential distalization using clear aligners and micro-implant anchorage: a finite element study
    Liu, Xulin
    Wu, Junjie
    Cheng, Yuxun
    Gao, Jie
    Wen, Yi
    Zhang, Yubohan
    Luo, Houzhuo
    Jin, Zuolin
    Ma, Yanning
    PROGRESS IN ORTHODONTICS, 2023, 24 (01)
  • [40] Effective contribution ratio of the molar during sequential distalization using clear aligners and micro-implant anchorage: a finite element study
    Xulin Liu
    Junjie Wu
    Yuxun Cheng
    Jie Gao
    Yi Wen
    Yubohan Zhang
    Houzhuo Luo
    Zuolin Jin
    Yanning Ma
    Progress in Orthodontics, 24