Accumulated biomechanical effects of mandibular molar mesialization using clear aligners with auxiliary devices: an iterative finite element analysis

被引:10
|
作者
Lyu, Xinwei [1 ,2 ,3 ]
Cao, Xing [1 ,2 ,3 ]
Chen, Luxian [1 ,2 ,3 ]
Liu, Yuyao [1 ,2 ,3 ]
Li, Huilin [1 ,2 ,3 ]
Hu, Cheng [1 ,2 ,3 ]
Tan, Jiali [1 ,2 ,3 ]
机构
[1] Sun Yat Sen Univ, Hosp Stomatol, Dept Orthodont, Guangzhou 510055, Peoples R China
[2] Sun Yat Sen Univ, Guangdong Prov Key Lab Stomatol, Guangzhou 510080, Peoples R China
[3] Sun Yat Sen Univ, Guanghua Sch Stomatol, Guangzhou 510080, Peoples R China
基金
中国国家自然科学基金;
关键词
Finite element analysis; Clear aligners; Numerical simulation; Molar mesialization; Long-term tooth movement; Biomechanics; ORTHODONTIC TOOTH MOVEMENT; PERMANENT 1ST MOLAR; PERIODONTAL-LIGAMENT; FORCE; PROTRACTION; RETRACTION; TORQUE; SPACE;
D O I
10.1186/s40510-023-00462-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThe biomechanics generated by the clear aligner (CA) material changes continuously during orthodontic tooth movement, but this factor remains unknown during the computer-aid design process and the predictability of molars movement is not as expected. Therefore, the purpose of this study was to propose an iterative finite element method to simulate the long-term biomechanical effects of mandibular molar mesialization (MM) in CA therapy under dual-mechanical systems.MethodsThree groups including CA alone, CA with a button, and CA with a modified lever arm (MLA) were created. Material properties of CA were obtained by in vitro mechanical experiments. MM was conducted by the rebound force exerted by CA material and the mesial elastic force (2N, 30 degrees to the occlusal plane) applied to the auxiliary devices. Stress intensity and distribution on periodontal ligament (PDL), attachment, button and MLA, and displacement of the second molar (M2) during the iterations were recorded.ResultsThere was a significant difference between the initial and cumulative long-term displacement. Specifically, compared to the beginning, the maximum stress of PDL decreased by 90% on average in the intermediate and final steps. The aligner was the main mechanical system at first, and then, the additional system exerted by the button and MLA dominated gradually. The stress of attachments and auxiliary devices is mainly concentrated on their interfaces with the tooth. Additionally, MLA provided a distal tipping and extrusive moment, which was the only group that manifested a total mesial displacement of the root.ConclusionsThe innovatively designed MLA was more effective in reducing undesigned mesial tipping and rotation of M2 than the traditional button and CA alone, which provided a therapeutic method for MM. The proposed iterative method simulated tooth movement by considering the mechanical characteristic of CA and its long-term mechanical force changes, which will facilitate better movement prediction and minimize the failure rate.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Accumulated biomechanical effects of mandibular molar mesialization using clear aligners with auxiliary devices: an iterative finite element analysis
    Xinwei Lyu
    Xing Cao
    Luxian Chen
    Yuyao Liu
    Huilin Li
    Cheng Hu
    Jiali Tan
    Progress in Orthodontics, 24
  • [2] A finite element analysis of the effects of semipontic design on tooth movement during mesialization of the mandibular second molar with clear aligners
    Akan, Burcu Ece Koru
    Kircelli, Beyza Hanciog
    Bozkurt, Aylin Pasagolu
    Gogen, Hakan
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2024, 166 (05) : 490 - 502
  • [3] Effects of Mandibular Extractions with Clear Aligners: A Finite Element Analysis
    Feng Q.
    Chu F.
    Chen R.
    Pan X.
    Journal of Shanghai Jiaotong University (Science), 2021, 26 (3) : 377 - 382
  • [4] Effects of Mandibular Extractions with Clear Aligners: A Finite Element Analysis
    Feng, Qiping
    Chu, Fengting
    Chen, Rongjing
    Pan, Xiaogang
    Journal of Shanghai Jiaotong University (Science), 2021, 26 (03) : 377 - 382
  • [5] Different biomechanical effects of clear aligners in closing maxillary and mandibular extraction spaces: Finite element analysis
    Liu, Jun-qi
    Zhu, Guan-yin
    Wang, Yi-gan
    Zhang, Bo
    Yao, Ke
    Zhao, Zhi-he
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2023, 163 (06) : 811 - 824.e2
  • [6] Biomechanical effects of different mandibular movements and torque compensations during mandibular advancement with clear aligners: a finite element analysis
    Wang, Ya
    Daraqel, Baraa
    Wang, Ying
    Yang, Dan
    Dong, Yihan
    Hu, Yun
    Zheng, Leilei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [7] Biomechanical analysis for total mesialization of the mandibular dentition: A finite element study
    Kawamura, Jun
    Park, Jae Hyun
    Kojima, Yukio
    Kook, Yoon-Ah
    Kyung, Hee-Moon
    Chae, Jong-Moon
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2019, 22 (04) : 329 - 336
  • [8] Biomechanical analysis for different mandibular total distalization methods with clear aligners: A finite element study
    Oh, Sewoong
    Choi, Youn-Kyung
    Kim, Sung-Hun
    Ko, Ching-Chang
    Kim, Ki Beom
    Kim, Yong-Il
    KOREAN JOURNAL OF ORTHODONTICS, 2023, 53 (06) : 420 - 430
  • [9] Effects of Attachment Orientation and Designed Vertical Movement on Molar Distalisation With Clear Aligners: A Biomechanical Finite Element Study
    Li, Jialun
    Yang, Yi
    He, Xian
    Lai, Wenli
    Long, Hu
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2025, 28 (02) : 296 - 303
  • [10] Biomechanical Characteristics of Maxillary Molar Distalization Using Different Attachments with Clear Aligners: A 3-Dimensional Finite Element Analysis
    Chi, Jingwen
    Yang, Lixia
    Liu, Yicong
    Yang, Jianjun
    Deng, Jing
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2022, 12 (09) : 1738 - 1744