Four-dimensional digital subtraction angiography to assess cerebral arteriovenous malformations

被引:2
|
作者
Xiang, Weichu [1 ]
Yan, Linhai [2 ]
Zhao, Yueyuan [1 ]
Yang, Ming [1 ]
Bai, Sanli [1 ]
Ma, Lianting [1 ]
Pan, Li [1 ]
机构
[1] Gen Hosp Cent Theater Command, Dept Neurosurg, 627 Wuluo Rd, Wuhan 430074, Peoples R China
[2] Guangzhou Med Univ, Dept Neurosurg, Affiliated Hosp 2, Guangzhou, Peoples R China
关键词
4D DSA; 4D DSA prototype; agreement analysis; cerebral arteriovenous malformation; 3D ROTATIONAL ANGIOGRAPHY; 4D DSA; DISPLAY; 2D;
D O I
10.1111/jon.13065
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose The performance of a novel prototype four-dimensional (4D) digital subtraction angiography (DSA) for cerebral arteriovenous malformation (AVM) diagnosis was evaluated and compared with that of two-dimensional (2D) and three-dimensional (3D) DSA. Methods In this retrospective study, 37 consecutive cerebral AVM patients were included. The standard diagnostic results were concluded from the 2D and 3D DSA. Two 4D DSA volumes were reconstructed for each patient by a commercial and a prototype software, then evaluated by two independent experienced neurosurgeons, who were blinded to the diagnosis and treatment process. The evaluation results were compared with the diagnostic results on Spetzler-Martin (SM) Grading Scale, number of feeding arteries, number of draining veins, and intranidal aneurysms. Results Complete agreement was achieved between 4D DSA and 2D and 3D DSA in SM Grading Scale and intracranial aneurysm identification (agreement coefficient: 1) for both reviewers. The agreement coefficients were .888 and .917 for both reviewers in feeding artery number determination using 4D DSA product and 4D DSA prototype, respectively. The agreement coefficients in draining vein number determination were all larger than .94 for both reviewers using both 4D DSA volumes. Conclusions The performance of this prototype 4D DSA in cerebral AVMs diagnosis was largely equivalent to that of 2D and 3D DSA combination. Four-dimensional DSA can be regarded as a very good complement for 2D DSA in cerebral AVM diagnosis.
引用
收藏
页码:67 / 72
页数:6
相关论文
共 50 条
  • [1] MR digital subtraction angiography of cerebral arteriovenous malformations
    Tsuchiya, K
    Katase, S
    Yoshino, A
    Hachiya, J
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (04) : 707 - 711
  • [2] Surgical management of cerebral arteriovenous malformations with intraoperative digital subtraction angiography
    Hashimoto, H
    Iida, J
    Hironaka, Y
    Sakaki, T
    JOURNAL OF CLINICAL NEUROSCIENCE, 2000, 7 : 33 - 35
  • [3] Four-dimensional digital subtraction angiography for exploration of spinal cord vascular malformations: preliminary experience
    Clarencon, Frederic
    Lenck, Stephanie
    Shotar, Eimad
    Boch, Anne-Laure
    Lefevre, Etienne
    Premat, Kevin
    Amador, Maria Del Mar
    Sourour, Nader-Antoine
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2021, 13 (01) : 69 - 74
  • [4] Four-Dimensional Digital Subtraction Angiography: Implementation and Demonstration of Feasibility
    Parry, Phillip V.
    Ducruet, Andrew F.
    WORLD NEUROSURGERY, 2014, 81 (3-4) : 454 - 455
  • [5] Can angiogenesis be reliably determined on digital subtraction angiography in cerebral arteriovenous malformations?
    Das, Suparna
    Raffalli-Ebezant, Helen
    Kasher, Paul R.
    Parry-Jones, Adrian
    Patel, Hiren C.
    BRITISH JOURNAL OF NEUROSURGERY, 2024,
  • [6] Spatiotemporal Disentanglement of Arteriovenous Malformations in Digital Subtraction Angiography
    Baur, Kathleen
    Xiong, Xin
    Torio, Erickson
    Du, Rose
    Juvekar, Parikshit
    Dorent, Reuben
    Golby, Alexandra
    Frisken, Sarah
    Haouchine, Nazim
    MEDICAL IMAGING 2024: IMAGE PROCESSING, 2024, 12926
  • [7] Digital subtraction angiography for arteriovenous malformations in stereotactic radiosurgery
    Piovan, E
    DalSasso, M
    Urbani, GP
    Sartori, R
    Foroni, R
    Benati, A
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1996, 66 : 57 - 62
  • [8] Arteriovenous malformations: Assessment by MR digital subtraction angiography
    Griffiths, PD
    Warren, DJ
    Hoggard, N
    Anderson, B
    Romanowski, CA
    Wilkinson, ID
    RADIOLOGY, 2000, 214 (02) : 612 - 612
  • [9] Accuracy of four-dimensional CT angiography in detection and characterisation of arteriovenous malformations and dural arteriovenous fistulas
    Biswas, Shubhabrata
    Chandran, Arun
    Radon, Mark
    Puthuran, Mani
    Bhojak, Maneesh
    Nahser, Hans Christean
    Das, Kumar
    NEURORADIOLOGY JOURNAL, 2015, 28 (04): : 376 - 384
  • [10] Four-dimensional digital subtraction angiography for the vascular anatomical diagnosis of dural arteriovenous malformation: Comparison with the conventional method
    Ishikawa, Kojiro
    Nishihori, Masahiro
    Izumi, Takashi
    Oshima, Ryosuke
    Uemura, Takeshi
    Kanamori, Fumiaki
    Uda, Kenji
    Yokoyama, Kinya
    Araki, Yoshio
    Saito, Ryuta
    INTERVENTIONAL NEURORADIOLOGY, 2024, 30 (05) : 738 - 745