An In Vitro Comparison of Zirconia and Hybrid Ceramic Crowns With Heavy Chamfer and Shoulder Finish Lines

被引:0
|
作者
Yadav, Priyanka [1 ]
Sharma, Vineet [2 ]
Paliwal, Jyoti [1 ]
Meena, Kamal K. [1 ]
Madaan, Rahul [3 ]
Gurjar, Balwant [1 ]
机构
[1] Rajasthan Univ Hlth Sci RUHS, Prosthodont, Coll Dent Sci, Jaipur, India
[2] Rajasthan Univ Hlth Sci RUHS, Dent, Coll Dent Sci, Jaipur, India
[3] Community Hlth Ctr, Dent, Jalore, India
关键词
internal gap; marginal gap; zirconia; hybrid ceramic; finish line configuration; INTERNAL FIT; MARGINAL FIT; ADAPTATION; THICKNESS;
D O I
10.7759/cureus.33940
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeThis in vitro study aimed to compare the marginal fit and internal adaptation of computer-aided designed and computer-aided manufactured (CAD-CAM) zirconia and hybrid ceramic crowns on heavy chamfer and shoulder finish line designs using silicon replica method.Materials and methodsForty die samples were divided into four groups of 10 dies each. Out of 40 diecasts scanned, zirconia crowns were milled on 20 casts (10 prepared with shoulder and 10 prepared with heavy chamfer finish line design), while hybrid ceramic crowns were milled on the rest of the 20 casts. After milling crowns, the silicone replica technique measured the marginal fit and internal adaptation.ResultsThe heavy chamfer finish line design provided a better marginal fit than the shoulder finish line design for zirconia and hybrid ceramic crowns. Hybrid ceramic crowns had a better marginal fit and internal adaptation than zirconia crowns, both at heavy chamfer and shoulder finish line design. The gap at the margin was less than the axial and occlusal walls, and the maximum gap was observed in the occlusal area. In addition, the marginal gap was less than the internal gap, which showed a positive correlation with each other.ConclusionThe study concluded that the difference in CAD-CAM materials and finish line designs influences marginal fit and crown restoration's internal adaptation. A heavy chamfer finish line design provides a better marginal fit for zirconia and hybrid ceramic crowns than a shoulder finish line design. Hybrid ceramic crowns have a better marginal fit and internal adaptation than zirconia crowns in heavy chamfer and shoulder finish lines.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A comparison of fracture strength of yttrium-oxide-partially-stabilized zirconia ceramic crowns with varying core thickness, shapes and veneer ceramics
    Sundh, A
    Sjögren, G
    JOURNAL OF ORAL REHABILITATION, 2004, 31 (07) : 682 - 688
  • [42] Comparison of Regular and Speed Sintering on Low-Temperature Degradation and Fatigue Resistance of Translucent Zirconia Crowns for Implants: An In Vitro Study
    Kongkiatkamon, Suchada
    Peampring, Chaimongkon
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2022, 13 (04)
  • [43] (In-Vitro Comparison between Closed Versus Open CAD/CAM Systems) Comparison between Closed and Open CAD/CAM Systems by Evaluating the Marginal Fit of Zirconia-Reinforced Lithium Silicate Ceramic Crowns
    Ben-Izhack, Gil
    Shely, Asaf
    Koton, Omer
    Meirowitz, Avi
    Levartovsky, Shifra
    Dolev, Eran
    APPLIED SCIENCES-BASEL, 2021, 11 (10):
  • [44] Proximal humeral osteolysis and glenoid radiolucent lines in an anatomic shoulder arthroplasty: a comparison of a ceramic and a metal humeral head component
    Bell, Simon N.
    Christmas, Maxim U. S., I
    Coghlan, Jennifer A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (05) : 913 - 923
  • [45] Impact of Coping Veneering Techniques on the Survival of Implant-Supported Zirconia-Based-Crowns Cemented to Hybrid-Abutments: An-In-Vitro Study
    Elshiyab, Shareen Hayel
    Nawafleh, Noor
    Khan, Usman
    Ochsner, Andreas
    George, Roy
    BIOENGINEERING-BASEL, 2020, 7 (04): : 1 - 14
  • [46] Accuracy of the intaglio surface of 3D-printed hybrid resin-ceramic crowns, veneers and table-tops: An in vitro study
    Metin, Dilan Seda
    Schmidt, Franziska
    Beuer, Florian
    Prause, Elisabeth
    Ashurko, Igor
    Sarmadi, Bardia Saadat
    Unkovskiy, Alexey
    JOURNAL OF DENTISTRY, 2024, 144
  • [47] In vitro Evaluation of the Marginal Fit and Internal Adaptation of Zirconia and Lithium Disilicate Single Crowns: Micro-CT Comparison Between Different Manufacturing Procedures
    Riccitiello, Francesco
    Amato, Massimo
    Leone, Renato
    Spagnuolo, Gianrico
    Sorrentino, Roberto
    OPEN DENTISTRY JOURNAL, 2018, 12 : 160 - 172
  • [48] Marginal and internal fit of pressed ceramic crowns made from conventional and computer-aided design and computer-aided manufacturing wax patterns: An in vitro comparison
    Shamseddine, Loubna
    Mortada, Rola
    Rifai, Khaldoun
    Chidiac, Jose Johann
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (02): : 242 - 248
  • [49] Influence of surface pretreatment using cold-active atmospheric pressure plasma on bond strength of CAD-CAM-fabricated hybrid ceramic crowns: an in-vitro study
    Georgi Kostadinov
    Carolin-Isabel Görgen
    Irene Schmidtmann
    Gernot Weibrich
    Samir Abou-Ayash
    Stefan Wentaschek
    International Journal of Implant Dentistry, 10 (1)
  • [50] Internal fit and marginal adaptation of all-ceramic implant-supported hybrid abutment crowns with custom-milled screw-channels on Titanium-base: in-vitro study
    Fakhr, Marwa Wagih Zaky Fouad
    Alansary, Hesham
    Hassanien, Eman Ezzat Youssef
    BMC ORAL HEALTH, 2024, 24 (01):