Design of a Medium Scale Ambient PM2.5 Cleaning System

被引:0
|
作者
Chen, Sheng-Chieh [1 ]
Cao, Qingfeng [2 ]
Kuehn, Thomas H. [2 ]
Lo, Charles [2 ]
Sahu, Manoranjan [3 ]
Mayya, Yelia S. [3 ]
Pui, David Y. H. [2 ]
机构
[1] Virginia Commonwealth Univ, Mech & Nucl Engn, Richmond, VA 23284 USA
[2] Univ Minnesota, Dept Mech Engn, Minneapolis, MN USA
[3] Indian Inst Technol, Mumbai, India
关键词
PM; 2; 5; Lung cancer; Filtration; Electret; Area control; EFFICIENCY;
D O I
10.4209/aaqr.220437
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
High concentrations of ambient particulate matter (PM) have caused millions of premature deaths annually worldwide. The source control strategy was normally implemented to bring the PM pollution down to meet the standards. However, it took more than 50 years for UK and US. As PM pollution is hurting people's health on daily basis in many countries, a fast and inexpensive control technology should be developed to remedy the slow pace of source control. It should be applied in highly polluted areas, e.g., cities and industrial parks, where people are spending a considerable time outdoors. In this study, a medium-scale filter-based blower-driven cleaning system was designed based on a computational fluid dynamic (CFD) simulation and experiments. We found the system with a dimension of 20 m (L) x 20 m (W) x 23 m (H) using 40 sets of 40-HP blowers can output -1000 m3 s-1 (CMS) of cleaned air. In PM removal, the design of the system, including the filter specifications, filter bank arrangement, and filter quantity, is crucial which results in the PM filtration efficiency, filter service life, and energy consumption. The clean air delivery rate (CADR), the product of the system flow rate (1000 CMS) and filtration efficiency (> 80%), is expected to be more than 800 CMS or -70,000,000 m3 daATIN SMALL LETTER Y WITH ACUTE1 (CMD). The experiments showed that the filter service life is expected to be 2 and 6 months for the prefilter and final filter, respectively, under total suspended particulate and PM2.5 concentrations of 600 and 300 mu g m-3, respectively. The CFD simulations showed the area of the effective PM2.5 reduction zone (> 50% PM2.5 concentration reduction) is as large as -300 m in diameter by this system. The CFD model also shows deploying 400 cleaning systems with 1 km apart, the PM2.5 reduced zone can cover an area of 400 km2.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Sources of PM10 and PM2.5 in Cairo’s ambient air
    M. Abu-Allaban
    D. H. Lowenthal
    A. W. Gertler
    M. Labib
    Environmental Monitoring and Assessment, 2007, 133 : 417 - 425
  • [22] Source apportionment of ambient PM10 and PM2.5 in Haikou, China
    Fang, Xiaozhen
    Bi, Xiaohui
    Xu, Hong
    Wu, Jianhui
    Zhang, Yufen
    Feng, Yinchang
    ATMOSPHERIC RESEARCH, 2017, 190 : 1 - 9
  • [23] PM2.5 of ambient origin:: Estimates and exposure errors relevant to PM epidemiology
    Meng, QY
    Turpin, BJ
    Polidori, A
    Lee, JH
    Weisel, C
    Morandi, M
    Colome, S
    Stock, T
    Winer, A
    Zhang, JF
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (14) : 5105 - 5112
  • [24] Sources of PM10 and PM2.5 in Cairo's ambient air
    Abu-Allaban, M.
    Lowenthal, D. H.
    Gertler, A. W.
    Labib, M.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2007, 133 (1-3) : 417 - 425
  • [25] Source apportionment of ambient PM10 and PM2.5 in Haikou, China
    Fang X.
    Bi X.
    Xu H.
    Wu J.
    Zhang Y.
    Feng Y.
    Atmospheric Research, 2017, 190 : 1 - 9
  • [27] Interactions of chemical components in ambient PM2.5 with influenza viruses
    Hsiao, Ta-Chih
    Cheng, Po-Ching
    Chi, Kai Hsien
    Wang, Hung-Yang
    Pan, Shih-Yu
    Kao, Ching
    Lee, Yueh-Lun
    Kuo, Han-Pin
    Chung, Kian Fan
    Chuang, Hsiao-Chi
    Journal of Hazardous Materials, 2022, 423
  • [28] Development and evaluation of a continuous ambient PM2.5 mass monitor
    Babich, P
    Wang, PY
    Allen, G
    Sioutas, C
    Koutrakis, P
    AEROSOL SCIENCE AND TECHNOLOGY, 2000, 32 (04) : 309 - 324
  • [29] Personal and ambient PM2.5 exposure assessment in the city of Agra
    Habil, M.
    Massey, D. D.
    Taneja, A.
    DATA IN BRIEF, 2016, 6 : 495 - 502
  • [30] Status and characteristics of ambient PM2.5 pollution in global megacities
    Cheng, Zhen
    Luo, Lina
    Wang, Shuxiao
    Wang, Yungang
    Sharma, Sumit
    Shimadera, Hikari
    Wang, Xiaoliang
    Bressi, Michael
    de Miranda, Regina Maura
    Jiang, Jingkun
    Zhou, Wei
    Fajardo, Oscar
    Yan, Naiqiang
    Hao, Jiming
    ENVIRONMENT INTERNATIONAL, 2016, 89-90 : 212 - 221