Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach

被引:3
|
作者
Chemla, Denis [1 ]
Agnoletti, Davide [2 ,3 ]
Jozwiak, Mathieu [4 ,5 ]
Zhang, Yi [6 ,7 ]
Protogerou, Athanase D. [8 ]
Millasseau, Sandrine [9 ]
Blacher, Jacques [6 ]
机构
[1] Hop Marie Lannelongue, INSERM UMRS 999, F-92350 Le Plessis Robinson, France
[2] Univ Bologna, Hypertens & Cardiovasc Risk Res Ctr, Dept Med & Surg Sci, I-40138 Bologna, Italy
[3] IRCCS Azienda Osped Univ Bologna, Heart Chest & Vasc Dept, Cardiovasc Internal Med, I-40138 Bologna, Italy
[4] CHU Nice, Serv Med Intens Reanimat, F-06200 Nice, France
[5] Univ Cote dAzur, Unite Rech Clin Cote dAzur, UR2CA, F-06200 Nice, France
[6] Univ Paris Cite, Res Ctr Epidemiol & Biostat, Hotel Dieu, AP HP,Diag & Therapeut Ctr,Sorbonne Paris Cite,CRE, 1,Pl Parvis Notre Dame, F-75004 Paris CRESS, France
[7] Tongji Univ, Shanghai Peoples Hosp 10, Dept Cardiol, Sch Med, Middle Yanchang Rd 301, Shanghai 200072, Peoples R China
[8] Natl & Kapodistrian Univ Athens, Dept Med, Clin & Lab Pathophysiol, Cardiovasc Prevent & Res Unit, Athens 10679, Greece
[9] Pulse Wave Consulting, F-95320 St Leu La Foret, France
来源
JOURNAL OF PERSONALIZED MEDICINE | 2023年 / 13卷 / 08期
关键词
central pressure; aortic pressure; arterial tonometry; central hemodynamics; mean arterial pressure; systolic blood pressure; EUROPEAN-SOCIETY; AORTIC PRESSURE; PULSE PRESSURE; WORKING GROUP; ACCURACY; DEVICES; AMPLIFICATION; CALIBRATION; MORTALITY;
D O I
10.3390/jpm13081244
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Backround. Central systolic blood pressure (cSBP) provides valuable clinical and physiological information. A recent invasive study showed that cSBP can be reliably estimated from mean (MBP) and diastolic (DBP) blood pressure. In this non-invasive study, we compared cSBP calculated using a Direct Central Blood Pressure estimation (DCBP = MBP2/DBP) with cSBP estimated by radial tonometry. Methods. Consecutive patients referred for cardiovascular assessment and prevention were prospectively included. Using applanation tonometry with SphygmoCor device, cSBP was estimated using an inbuilt generalized transfer function derived from radial pressure waveform, which was calibrated to oscillometric brachial SBP and DBP. The time-averaged MBP was calculated from the radial pulse waveform. The minimum acceptable error (DCBP-cSBP) was set at <= 5 (mean) and <= 8 mmHg (SD). Results. We included 160 patients (58 years, 54%men). The cSBP was 123.1 +/- 18.3 mmHg (range 86-181 mmHg). The (DCBP-cSBP) error was 1.4 +/- 4.9 mmHg. There was a linear relationship between cSBP and DCBP (R-2 = 0.93). Forty-seven patients (29%) had cSBP values >= 130 mmHg, and a DCBP value > 126 mmHg exhibited a sensitivity of 91.5% and specificity of 94.7% in discriminating this threshold (Youden index = 0.86; AUC = 0.965). Conclusions. Using the DCBP formula, radial tonometry allows for the robust estimation of cSBP without the need for a generalized transfer function. This finding may have implications for risk stratification.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] ESTIMATION OF CENTRAL BLOOD PRESSURE BY CAROTID TONOMETRY, RADIAL TONOMETRY, AND BRACHIAL PLETHYSMOGRAPHY: A COMPARATIVE STUDY
    Cheng, Hao-min
    Sung, Shih-Hsien
    Hsu, Pai-Feng
    Wang, Kang-Ling
    Lee, Wen-Shin
    Yu, Wen-Chung
    Lin, Yao-Ping
    Chen, Chen-Huan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [12] A NOVEL NON-INVASIVE METHOD FOR ESTIMATING CENTRAL SYSTOLIC BLOOD PRESSURE USING AMBULATORY BLOOD PRESSURE MONITORING
    Alvarez-Montoya, Diego
    Gallo-Villegas, Jaime
    Aristizabal-Ocampo, Dagnovar
    JOURNAL OF HYPERTENSION, 2024, 42 (SUPPL 3)
  • [13] Cuffless and Non-invasive Systolic Blood Pressure Estimation for Aged Class by Using a Photoplethysmograph
    Suzuki, Satomi
    Oguri, Koji
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1327 - +
  • [14] Continuous Non-invasive Blood Pressure Monitoring Based on Applanation Tonometry
    Ariyadamrogkwan, Chollitha
    Chitsakul, Kitiphol
    Treetriluxana, Suradaj
    2014 FOURTH JOINT INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONIC AND ELECTRICAL ENGINEERING (JICTEE 2014), 2014,
  • [15] The association of aortic pulse wave velocity with non-invasive central and brachial systolic blood pressure
    Cameron, JD
    McGrath, BP
    JOURNAL OF HYPERTENSION, 2004, 22 : S199 - S199
  • [16] Correction Factor Estimation for a Parametric Model between Pulse Transit Time and Systolic Blood Pressure, for Non-Invasive Blood Pressure Estimation
    De Alwis, W. U. C.
    Rajapaksha, R. N. S.
    Ranaweera, N. N. S.
    Pitigalaarachchi, P. A. P. M. B.
    Pasqual, A.
    TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 2620 - 2625
  • [17] DEVICE-SPECIFIC EMPIRICAL CORRECTION EQUATIONS FOR ACCURATE NON-INVASIVE ESTIMATION OF CENTRAL SYSTOLIC BLOOD PRESSURE IN CHILDREN AND ADOLESCENTS
    Mynard, Jonathan
    Harrington, Hilary
    Smolich, Joseph
    Avolio, Alberto
    Cheung, Michael
    JOURNAL OF HYPERTENSION, 2021, 39 : E400 - E400
  • [18] A Non-Invasive Continuous Blood Pressure Estimation Approach Based on Machine Learning
    Chen, Shuo
    Ji, Zhong
    Wu, Haiyan
    Xu, Yingchao
    SENSORS, 2019, 19 (11)
  • [19] Non-invasive Blood Pressure Estimation Using Phonocardiogram
    Dastjerdi, Amirhossein Esmaili
    Kachuee, Mohammad
    Shabany, Mahdi
    2017 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2017, : 80 - 83
  • [20] Estimation of Blood Pressure from Non-invasive Data
    Shukla, Satya Narayan
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 1772 - 1775