Titanium niobium nitride knee implants are not inferior to chrome cobalt components for primary total knee arthroplasty at medium-term follow-up

被引:5
|
作者
Thienpont, Emmanuel [1 ]
机构
[1] Clin Univ St Luc, Ave Hippocrate 10, B-1200 Brussels, Belgium
关键词
Knee arthroplasty; Metal allergy; Titanium niobium; Revision; METAL SENSITIVITY; HYPERSENSITIVITY REACTIONS; ALLERGY; TKA; ASSOCIATION; DERMATITIS; REVISION; NICKEL; RISK; WEAR;
D O I
10.1007/s00402-022-04754-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Oxidized zirconium (Oxinium), titanium nitride (TiN) or titanium niobium nitride (TiNbN) coated implants became in recent years available for an increasing amount of total knee arthroplasty (TKA) systems. The hypothesis of this study was that the use of TiNbN-coated components would not lead to inferior results compared to conventional implants and that none of the metal hypersensitivity patients receiving TiNbN-coated implants would require revision for metal allergy.Materials and methods This retrospective study compared 53 Titanium Niobium Nitride coated TKA with 103 conventional chrome cobalt implants of the same design. Patients were evaluated at a minimal follow-up of 3 years.Results No differences in clinical, radiological or patient-reported outcome measurements were observed between these groups. A survivorship of 96% without differences in revision rates was observed at medium-term follow-up of 6.5 years.Discussion Metal allergy leading to contact or generalized dermatitis after TKA is very rare and usually linked to chrome or cobalt hypersensitivity. Nickel release from knee implants has not been shown to lead to cutaneous symptoms, but unexplained pain and swelling, peri-prosthetic osteolysis and component loosening remain potential issues not fully understood. The use of coated implants eliminates this factor from the diagnostic equation in case of postoperative dissatisfaction.Conclusion The use of titanium niobium nitride coated implants for primary knee osteoarthritis in self-reported metal hypersensitivity patients shows similar outcomes and survivorship rates as conventional chrome cobalt TKA, with no revisions for allergy at medium-term follow-up.
引用
收藏
页码:5269 / 5275
页数:7
相关论文
共 50 条
  • [31] Hydrotherapy after total knee arthroplasty. A follow-up study
    Giaquinto, S.
    Ciotola, E.
    Dall'Armi, V.
    Margutti, F.
    ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2010, 51 (01) : 59 - 63
  • [32] Revision total knee arthroplasty with modular cemented stems - Long-term follow-up
    Mabry, Tad M.
    Vessely, Michael B.
    Schleck, Cathy D.
    Harmsen, William Scott
    Berry, Daniel J.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (06): : 100 - 105
  • [33] Revision Total Knee Arthroplasty Using Metaphyseal Sleeves at Short-term Follow-up
    Huang, Ronald
    Barrazueta, Gustavo
    Ong, Alvin
    Orozco, Fabio
    Jafari, Mehdi
    Coyle, Catelyn
    Austin, Matthew
    ORTHOPEDICS, 2014, 37 (09) : e804 - e809
  • [34] Complex total knee arthroplasty using resection prostheses at mid-term follow-up
    Molenaers, Ben
    Arnout, Nele
    Bellernans, Johan
    KNEE, 2012, 19 (05): : 550 - 554
  • [35] Medium term outcome of Titanium Nitride, mobile bearing total knee Replacement
    Mohammed, Aso
    Metcalfe, Andy
    Woodnutt, David
    ACTA ORTHOPAEDICA BELGICA, 2014, 80 (02): : 269 - 275
  • [36] Medium-term patient's satisfaction after primary total knee arthroplasty: enhancing prediction for improved care
    Ulivi, Michele
    Orlandini, Luca
    D'Errico, Mario
    Perrotta, Riccardo
    Perfetti, Sofia
    Ferrante, Simona
    Dui, Linda Greta
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (02)
  • [37] Primary total knee arthroplasty using the genesis total knee arthroplasty system - 3- to 6-year follow-up study of 105 knees
    Mokris, JG
    Smith, SW
    Anderson, SE
    JOURNAL OF ARTHROPLASTY, 1997, 12 (01): : 91 - 98
  • [38] Unicompartmental knee arthroplasty has higher revisions than total knee arthroplasty at long term follow-up: a registry study on 6453 prostheses
    A. Di Martino
    B. Bordini
    F. Barile
    C. Ancarani
    V. Digennaro
    C. Faldini
    Knee Surgery, Sports Traumatology, Arthroscopy, 2021, 29 : 3323 - 3329
  • [39] Unicompartmental knee arthroplasty has higher revisions than total knee arthroplasty at long term follow-up: a registry study on 6453 prostheses
    Di Martino, A.
    Bordini, B.
    Barile, F.
    Ancarani, C.
    Digennaro, V.
    Faldini, C.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2021, 29 (10) : 3323 - 3329
  • [40] Associations of the Oxford Knee Score and knee arthroplasty revision at long-term follow-up
    Tay, Mei Lin
    Monk, A. Paul
    Frampton, Chris M. M.
    Hooper, Gary J. J.
    Young, Simon W. W.
    ANZ JOURNAL OF SURGERY, 2023, 93 (1-2) : 310 - 315