Effects of Ionizing Radiation on Cardiac Implantable Electronic Devices (CIEDs) in Patients with Esophageal Cancer Undergoing Radiotherapy: A Pilot Study

被引:0
|
作者
Uzun, Davut D. [1 ,2 ,3 ]
Salatzki, Janek [2 ,3 ]
Xynogalos, Panagiotis [2 ,3 ]
Frey, Norbert [2 ,3 ]
Debus, Juergen [4 ,5 ,6 ,7 ,8 ,9 ]
Lang, Kristin [4 ,5 ,6 ]
机构
[1] Heidelberg Univ Hosp, Dept Anesthesiol, D-69120 Heidelberg, Germany
[2] Heidelberg Ctr Heart Rhythm Disorders HCR, D-69120 Heidelberg, Germany
[3] Heidelberg Univ Hosp, Dept Cardiol, D-69120 Heidelberg, Germany
[4] Heidelberg Univ Hosp, Dept Radiat Oncol, D-69120 Heidelberg, Germany
[5] Heidelberg Inst Radiat Oncol HIRO, D-69120 Heidelberg, Germany
[6] Natl Ctr Tumor Dis NCT, D-69120 Heidelberg, Germany
[7] Heidelberg Univ Hosp, Heidelberg Ion Beam Therapy Ctr HIT, Dept Radiat Oncol, D-69120 Heidelberg, Germany
[8] German Canc Res Ctr, Clin Cooperat Unit Radiat Oncol, D-69120 Heidelberg, Germany
[9] German Canc Consortium DKTK, Partner Site Heidelberg, D-69120 Heidelberg, Germany
关键词
radiotherapy; esophageal cancer; cardiac devices; toxicity; CARDIOVERTER-DEFIBRILLATORS; THERAPY; CHEMORADIOTHERAPY; RISK; MALFUNCTION; PACEMAKERS; EXPOSURE; ENERGY;
D O I
10.3390/cancers16030555
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary The number of cancer patients who require an implantable electronic heart device due to their heart disease is steadily increasing. Radiotherapy is an important treatment option for esophageal cancer, in addition to surgery and chemotherapy. Ionizing radiation can lead to serious malfunctions of cardiac devices, including complete loss of function with life-threatening consequences. There is already data in the literature on other types of cancer and radiotherapy. Esophageal cancer is rare, so there is limited information on patients with this cancer who need radiotherapy and have an electronic heart device. We retrospectively analyzed the occurrence of cardiac device malfunction in patients with esophageal cancer in our study between 2012 and 2022. By applying our internal treatment protocol, serious cardiac device malfunctions during, and after radiotherapy could be prevented. It is important to carefully plan and select the energy of the photons. The manufacturer's recommended dose limits should be observed.Abstract (1) Background: The prevalence of cancer patients relying on cardiac implantable electronic device (CIED) is steadily rising. The aim of this study was to evaluate RT-related malfunctions of CIEDs. (2) Methods: We retrospectively analyze sixteen patients with esophageal cancer who were treated with radiotherapy between 2012 and 2022 at the University Hospital Heidelberg. All patients underwent systemic evaluation including pre-therapeutic cardiological examinations of the CIED functionality and after every single irradiation. (3) Results: Sixteen patients, predominantly male (14) with a mean age of 77 (range: 56-85) years were enrolled. All patients received 28 fractions of radiotherapy with a cumulative total dose 58.8 Gy. The mean maximum dose at the CIEDs was 1.8 Gy. Following radiotherapy and during the one-year post-radiation follow-up period, there were no registered events associated with the treatment in this evaluation. (4) Conclusion: The study did not observe any severe CIED malfunctions following each radiation fraction or after completion of RT. Strict selection of photon energy and alignment with manufacturer-recommended dose limits appear to be important. Our study showed no major differences in the measured values of the pacing threshold, sensing threshold and lead impedance after RT.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Infective endocarditis in patients with cardiac implantable electronic devices: a nationwide study
    Mateos Gaitan, Roberto
    Boix-Palop, Lucia
    Munoz Garcia, Patricia
    Mestres, Carlos A.
    Marin Arriaza, Mercedes
    Pedraz Prieto, Alvaro
    de Alarcon Gonzalez, Aristides
    Gutierrez Carretero, Encarnacion
    Hernandez Meneses, Marta
    Goenaga Sanchez, Miguel Angel
    Cobo Belaustegui, Manuel
    Oteo Revuelta, Jose Antonio
    Gainzarain Arana, Juan Carlos
    Garcia Vazquez, Elisa
    Martinez-Selles, Manuel
    EUROPACE, 2020, 22 (07): : 1062 - 1070
  • [42] Radiotherapy-Induced Cardiac Implantable Electronic Device Dysfunction in Patients With Cancer
    Bagur, Rodrigo
    Chamula, Mathilde
    Brouillard, Emilie
    Lavoie, Caroline
    Nombela-Franco, Luis
    Julien, Anne-Sophie
    Archambault, Louis
    Varfalvy, Nicolas
    Gaudreault, Valerie
    Joncas, Sebastien X.
    Israeli, Zeev
    Parviz, Yasir
    Mamas, Mamas A.
    Lavi, Shahar
    AMERICAN JOURNAL OF CARDIOLOGY, 2017, 119 (02): : 284 - 289
  • [43] HOSPITAL VISITS OF PATIENTS ON CARDIAC IMPLANTABLE ELECTRONIC DEVICES (CIEDS) REMOTE MONITORING DURING THE COVID-19 PANDEMIC: SOCIOECONOMIC IMPLICATIONS
    Seo, Jiyoung
    Kharawala, Amrin
    Krishnan, Suraj
    Alhuarrat, Majd Al Deen
    Varrias, Dimitrios
    Apple, Samuel J.
    Selevany, Ibrahim
    Chudow, Jay
    Krumerman, Andrew
    Ferrick, Kevin J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 216 - 216
  • [44] Remote monitoring of patients with cardiac implantable electronic devices: a Southeast Asian, single-centre pilot study
    Lim, Paul Chun Yih
    Lee, Audry Shan Yin
    Chua, Kelvin Chi Ming
    Lim, Eric Tien Siang
    Chong, Daniel Thuan Tee
    Tan, Boon Yew
    Ho, Kah Leng
    Teo, Wee Siong
    Ching, Chi Keong
    SINGAPORE MEDICAL JOURNAL, 2016, 57 (07) : 372 - 377
  • [45] REMOTE MONITORING IN PATIENTS WITH CARDIAC IMPLANTABLE ELECTRONIC DEVICES (CIEDS) DURING THE COVID-19 PANDEMIC IN AN URBAN SETTING: SOCIOECONOMIC IMPLICATIONS
    Seo, Jiyoung
    Krishnan, Suraj
    Alhuarrat, Majd Al Deen
    Kharawala, Amrin
    Varrias, Dimitrios
    Apple, Samuel J.
    Selevany, Ibrahim
    Chudow, Jay
    Krumerman, Andrew
    Ferrick, Kevin J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 131 - 131
  • [46] Automatic consultation system for patients with cardiac implantable electronic devices undergoing magnetic resonance imaging
    Donghoon Han
    Ji Hyun Lee
    Il-Young Oh
    In-ho Chae
    Ho-Young Lee
    Youngjin Cho
    International Journal of Arrhythmia, 21 (1)
  • [47] Incidence of Radiotherapy Induced Cardiac Implantable Electronic Devices Malfunction: Australian -Based Observation Study
    Lin, Y. H.
    Azraai, M.
    Miura, D.
    Rodrigues, T.
    Nadurata, V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E408 - E408
  • [48] Intrinsic bleeding risk in patients with uninterrupted oral anticoagulation undergoing cardiac implantable electronic device procedures: A pilot study
    De Sensi, Francesco
    Paneni, Francesco
    Addonisio, Luigi
    Breschi, Marco
    Miracapillo, Gennaro
    Severi, Silva
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 176 (03) : 1420 - 1422
  • [49] Magnetic resonance imaging in patients with cardiac implantable electronic devices: A prospective study
    Navarro-Valverde, Cristina
    Ramos-Maqueda, Javier
    Jose Romero-Reyes, M.
    Esteve-Ruiz, Irene
    Garcia-Medina, Dolores
    Pavon-Jimenez, Ricardo
    Rodriguez-Gomez, Cristobal
    Leal-Del-Ojo, Juan
    Cayuela, Aurelio
    Molano-Casimiro, Francisco J.
    MAGNETIC RESONANCE IMAGING, 2022, 91 : 9 - 15
  • [50] RADIOTHERAPY IN PATIENTS WITH CARDIOVASCULAR IMPLANTABLE ELECTRONIC DEVICES: A SURVEY OF MULTI-DISCIPLINARY RADIATION ONCOLOGY PROFESSIONALS
    Safavi, Amir H.
    Elzibak, Alyaa H.
    Donovan, Elysia K.
    Detsky, Jay S.
    Louie, Alexander V.
    RADIOTHERAPY AND ONCOLOGY, 2020, 150 : S32 - S33