Effects of Ionizing Radiation on Cardiac Implantable Electronic Devices (CIEDs) in Patients with Esophageal Cancer Undergoing Radiotherapy: A Pilot Study

被引:0
|
作者
Uzun, Davut D. [1 ,2 ,3 ]
Salatzki, Janek [2 ,3 ]
Xynogalos, Panagiotis [2 ,3 ]
Frey, Norbert [2 ,3 ]
Debus, Juergen [4 ,5 ,6 ,7 ,8 ,9 ]
Lang, Kristin [4 ,5 ,6 ]
机构
[1] Heidelberg Univ Hosp, Dept Anesthesiol, D-69120 Heidelberg, Germany
[2] Heidelberg Ctr Heart Rhythm Disorders HCR, D-69120 Heidelberg, Germany
[3] Heidelberg Univ Hosp, Dept Cardiol, D-69120 Heidelberg, Germany
[4] Heidelberg Univ Hosp, Dept Radiat Oncol, D-69120 Heidelberg, Germany
[5] Heidelberg Inst Radiat Oncol HIRO, D-69120 Heidelberg, Germany
[6] Natl Ctr Tumor Dis NCT, D-69120 Heidelberg, Germany
[7] Heidelberg Univ Hosp, Heidelberg Ion Beam Therapy Ctr HIT, Dept Radiat Oncol, D-69120 Heidelberg, Germany
[8] German Canc Res Ctr, Clin Cooperat Unit Radiat Oncol, D-69120 Heidelberg, Germany
[9] German Canc Consortium DKTK, Partner Site Heidelberg, D-69120 Heidelberg, Germany
关键词
radiotherapy; esophageal cancer; cardiac devices; toxicity; CARDIOVERTER-DEFIBRILLATORS; THERAPY; CHEMORADIOTHERAPY; RISK; MALFUNCTION; PACEMAKERS; EXPOSURE; ENERGY;
D O I
10.3390/cancers16030555
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary The number of cancer patients who require an implantable electronic heart device due to their heart disease is steadily increasing. Radiotherapy is an important treatment option for esophageal cancer, in addition to surgery and chemotherapy. Ionizing radiation can lead to serious malfunctions of cardiac devices, including complete loss of function with life-threatening consequences. There is already data in the literature on other types of cancer and radiotherapy. Esophageal cancer is rare, so there is limited information on patients with this cancer who need radiotherapy and have an electronic heart device. We retrospectively analyzed the occurrence of cardiac device malfunction in patients with esophageal cancer in our study between 2012 and 2022. By applying our internal treatment protocol, serious cardiac device malfunctions during, and after radiotherapy could be prevented. It is important to carefully plan and select the energy of the photons. The manufacturer's recommended dose limits should be observed.Abstract (1) Background: The prevalence of cancer patients relying on cardiac implantable electronic device (CIED) is steadily rising. The aim of this study was to evaluate RT-related malfunctions of CIEDs. (2) Methods: We retrospectively analyze sixteen patients with esophageal cancer who were treated with radiotherapy between 2012 and 2022 at the University Hospital Heidelberg. All patients underwent systemic evaluation including pre-therapeutic cardiological examinations of the CIED functionality and after every single irradiation. (3) Results: Sixteen patients, predominantly male (14) with a mean age of 77 (range: 56-85) years were enrolled. All patients received 28 fractions of radiotherapy with a cumulative total dose 58.8 Gy. The mean maximum dose at the CIEDs was 1.8 Gy. Following radiotherapy and during the one-year post-radiation follow-up period, there were no registered events associated with the treatment in this evaluation. (4) Conclusion: The study did not observe any severe CIED malfunctions following each radiation fraction or after completion of RT. Strict selection of photon energy and alignment with manufacturer-recommended dose limits appear to be important. Our study showed no major differences in the measured values of the pacing threshold, sensing threshold and lead impedance after RT.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Radiotherapy (RT) and cardiac implantable electronic devices (CIEDs): a prospective study.
    Villa, E.
    Michelotti, F.
    Motta, M.
    Ravasio, A.
    Gherardi, D.
    Manazzale, V.
    Locatelli, F.
    Trombetta, L.
    Salmoiraghi, P.
    Mascioli, G.
    Vavassori, V.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S612 - S612
  • [2] Recommendations for Imaging Patients With Cardiac Implantable Electronic Devices (CIEDs)
    Vigen, Karl K.
    Reeder, Scott B.
    Hood, Maureen N.
    Steckner, Michael
    Leiner, Tim
    Dombroski, David A.
    Gulani, Vikas
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (05) : 1311 - 1317
  • [3] Safety verification of carbon-ion radiotherapy for patients with cardiac implantable electronic devices (CIEDs)
    Okano, Naoko
    Sakai, Makoto
    Shibuya, Kei
    Tsuda, Kazuhisa
    Kanzaki, Takao
    Sano, Masato
    Kaneko, Yoshiaki
    Ohno, Tatsuya
    JOURNAL OF RADIATION RESEARCH, 2022, 63 (01) : 122 - 127
  • [4] Prediction of radiation-induced malfunction for cardiac implantable electronic devices (CIEDs)
    Matsubara, Hiroaki
    Ezura, Takatomo
    Hashimoto, Yaichiro
    Karasawa, Kumiko
    Nishio, Teiji
    Tsuneda, Masato
    MEDICAL PHYSICS, 2020, 47 (04) : 1489 - 1498
  • [5] Monitoring Cardiovascular Implantable Electronic Devices (CIEDs) for Patients Receiving Radiotherapy (RT)
    Bowman, K.
    Popple, R.
    Doppalapudi, H.
    Fiveash, J. B.
    Meredith, R.
    Brezovich, I. A.
    Bonner, J. A.
    Spencer, S. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S599 - S599
  • [6] Management of cardiac implantable devices in patients undergoing radiotherapy
    Dobson, Rebecca
    Wright, David J.
    CURRENT PROBLEMS IN CANCER, 2018, 42 (04) : 443 - 448
  • [7] How to Manage Patients With Cardiac Implantable Electronic Devices Undergoing Radiation Therapy
    Fradley, Michael G.
    Lefebvre, Benedicte
    Carver, Joseph
    Cheung, Jim W.
    Feigenberg, Steven J.
    Lampert, Rachel
    Liu, Jennifer
    Rajagopalan, Bharath
    Lenihan, Daniel J.
    JACC: CARDIOONCOLOGY, 2020, 3 (03): : 447 - 451
  • [8] Management of Radiotherapy Patients with Cardiac Implantable Electronic Devices
    Miften, Moyed
    Mihailidis, D.
    Kry, S.
    Miften, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3240 - 3240
  • [9] Radiotherapy-induced malfunctions of cardiac implantable electronic devices in cancer patients
    Vincenzo L. Malavasi
    Giuseppina De Marco
    Jacopo F. Imberti
    Filippo Placentino
    Marco Vitolo
    Ercole Mazzeo
    Gianfranco Cicoria
    Edoardo Casali
    Vincenzo Turco
    Frank Lohr
    Giuseppe Boriani
    Internal and Emergency Medicine, 2020, 15 : 967 - 973
  • [10] Radiotherapy-induced malfunction in cancer patients with cardiac implantable electronic devices
    Imberti, J. F.
    Placentino, F.
    Malavasi, V. L.
    Demarco, G.
    Lohr, F.
    Boriani, G.
    EUROPEAN HEART JOURNAL, 2019, 40 : 290 - 290