Electrospinography for non-invasively recording spinal sensorimotor networks in humans

被引:1
|
作者
Steele, Alexander G. [1 ,2 ]
Faraji, Amir H. [2 ,3 ,4 ,5 ]
Contreras-Vidal, Jose L. [1 ]
机构
[1] Univ Houston, Lab Noninvas Brain Machine Interfaces, IUCRC BRAIN, N308 Engn Bldg 1, Houston, TX 77204 USA
[2] Houston Methodist Res Inst, Ctr Neuroregenerat, Dept Neurosurg, Houston, TX 77030 USA
[3] Houston Methodist Res Inst, Ctr Translat Neural Prosthet & Interfaces, Houston, TX 77030 USA
[4] Houston Methodist Res Inst, Clin Innovat Lab, Houston, TX 77030 USA
[5] Houston Methodist Hosp, Dept Neurol Surg, Houston, TX 77030 USA
关键词
spinal cord; non-invasive; electrospinography; EEG-DATA; CORD; STIMULATION;
D O I
10.1088/1741-2552/ad1782
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Currently, few non-invasive measures exist for directly measuring spinal sensorimotor networks. Electrospinography (ESG) is one non-invasive method but is primarily used to measure evoked responses or for monitoring the spinal cord during surgery. Our objectives were to evaluate the feasibility of ESG to measure spinal sensorimotor networks by determining spatiotemporal and functional connectivity changes during single-joint movements at the spinal and cortical levels. Approach. We synchronously recorded electroencephalography (EEG), electromyography, and ESG in ten neurologically intact adults while performing one of three lower-limb tasks (no movement, plantar-flexion and knee flexion) in the prone position. A multi-pronged approach was applied for removing artifacts using H-infinity filtering, artifact subspace reconstruction and independent component (IC) analysis. Next, data were segmented by task and ICs of EEG were clustered across participants. Within-participant analysis of ICs and ESG data was conducted, and ESG was characterized in the time and frequency domains. Generalized partial directed coherence analysis was performed within ICs and between ICs and ESG data by participant and task. Results. K-means clustering resulted in five clusters of ICs at Brodmann areas (BAs) 9, BA 8, BA 39, BA 4, and BA 22. Areas associated with motor planning, working memory, visual processing, movement, and attention, respectively. Time-frequency analysis of ESG data found localized changes during movement execution when compared to no movement. Lastly, we found bi-directional changes in functional connectivity (p < 0.05, adjusted for multiple comparisons) within IC's and between IC's and ESG sensors during movement when compared to the no movement condition. Significance. To our knowledge this is the first report using high density ESG for characterizing single joint lower limb movements. Our findings provide support that ESG contains information about efferent and afferent signaling in neurologically intact adults and suggests that we can utilize ESG to directly study the spinal cord.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Measuring fluid and slurry density and solids concentration non-invasively
    Bamberger, JA
    Greenwood, MS
    ULTRASONICS, 2004, 42 (1-9) : 563 - 567
  • [42] FORCED DIURESIS AS A TOOL FOR THE NON-INVASIVELY EVALUATION OF BLADDER SENSATION
    Heeringa, R.
    van Koeveringe, G.
    van Kerrebroeck, P.
    Gillespie, J.
    de Wachter, S.
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2010, 21 : S105 - S106
  • [43] Evaluation of a mathematical model to predict intrapulmonary shunt non-invasively
    Seear, M
    Malagon, I
    Hui, H
    Alexander, J
    Daoust, C
    Skippen, P
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (05): : 483 - 487
  • [44] A signal analysis algorithm for determining brain compliance non-invasively
    Manwaring, P
    Wichern, D
    Manwaring, M
    Manwaring, J
    Manwaring, K
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 353 - 356
  • [45] FORCED DIURESIS AS A TOOL FOR THE NON-INVASIVELY EVALUATION OF BLADDER SENSATION
    Heeringa, R.
    van Koeveringe, G.
    van Kerrebroeck, P.
    Gillespie, J.
    de Wachter, S.
    NEUROUROLOGY AND URODYNAMICS, 2010, 29 (06) : 909 - 910
  • [46] Watching stem cells in the skin of living mice non-invasively
    Uchugonova, Aisada
    Hoffman, Robert M.
    Weinigel, Martin
    Koenig, Karsten
    CELL CYCLE, 2011, 10 (12) : 2017 - 2020
  • [47] Design and Development offinger probefor diagnosis ofAnemia non-invasively
    Kumar, Yogesh
    Shaw, Vikash
    Rani, Parul
    Dhiman, Varun
    Jha, Ranjan
    Kumar, Sanjeev
    2019 3RD INTERNATIONAL CONFERENCE ON RECENT DEVELOPMENTS IN CONTROL, AUTOMATION & POWER ENGINEERING (RDCAPE), 2019, : 384 - 389
  • [48] Monitoring photocatalytic degradation mechanisms non-invasively with Raman spectroscopy
    Nee, Matthew J.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [49] Non-Invasively Silencing and Monitoring Machado-Joseph Disease
    Nobre, Rui
    Saraiva, Joana
    Fusco, Clelia
    Paixao, Susana
    Santana, Magda
    Petrella, Lorena
    Sereno, Jose
    Castelhano, Joao
    Castelo-Branco, Miguel
    Sena-Esteves, Miguel
    de Almeida, Luis Pereira
    MOLECULAR THERAPY, 2018, 26 (05) : 269 - 269
  • [50] Evaluation of a mathematical model to predict intrapulmonary shunt non-invasively
    Michael Seear
    Ignacio Malagon
    Henry Hui
    John Alexander
    Christopher Daoust
    Peter Skippen
    Canadian Journal of Anesthesia, 1999, 46 : 483 - 487