Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population

被引:14
|
作者
Choi, Wan Kyu [1 ]
Han, Hyo Ji [1 ]
Son, Hyeck-Soo [2 ]
Khoramnia, Ramin [2 ]
Auffarth, Gerd U. [2 ]
Choi, Chul Young [1 ]
机构
[1] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Sch Med, Dept Ophthalmol, 29 Saemunan Ro, Seoul 03181, South Korea
[2] Heidelberg Univ, Dept Ophthalmol, David J Apple Int Lab Ocular Pathol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
关键词
Eyhance; Tecnis; Monofocal IOL; Cataract; INTRAOCULAR-LENS; EXTENDED RANGE; PERFORMANCE; DEPTH;
D O I
10.1186/s12886-023-02897-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo compare the clinical outcomes of bilateral implantation of enhanced intermediate function intraocular lenses (IOLs) and standard monofocal IOLs.MethodsIn this prospective, randomized, comparative controlled study, we compared the visual outcomes of patients who underwent bilateral cataract surgery at the Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, with either enhanced monofocal IOLs (Tecnis Eyhance, ICB00, Johnson and Johnson Vision Care, Inc) (Group 1) or standard monofocal IOLs (Tecnis, ZCB00, Johnson and Johnson Vision Care, Inc) (Group 2). The assessment included monocular and binocular uncorrected distance visual acuity (UDVA), uncorrected intermediate (UIVA at 60 cm) and near (UNVA at 40 cm) visual acuity, uncorrected defocus curves, contrast sensitivity testing (CST), and reading speed test using Quality of vision was evaluated using the Visual Function Questionnaire (VFQ-25).ResultsAt 3-months postoperatively, monocular and binocular outcomes of UIVA and UNVA were statistically significantly better in Group 1 (P < 0.05). The binocular uncorrected defocus curve of Group 1 showed statistically significantly better outcomes at vergence ranges of -1.5 to -4.0 D (P < 0.05). Significantly higher reading speed test was also observed in Group 1 in all ranges tested (1.0 to 0.1 LogMAR) (P < 0.05). There were no statistically significant differences in CST between groups.ConclusionsBilateral implantation of enhanced monofocal IOLs provided better vision at intermediate and near distances compared to standard monofocal IOLs, while maintaining good distance vision and contrast sensitivity.
引用
收藏
页数:8
相关论文
共 44 条
  • [41] Comparative clinical outcomes of Tecnis toric IOL implantation in femtosecond laser-assisted cataract surgery and conventional phacoemulsification surgery
    Kai-Ran Lai
    Xiao-Bo Zhang
    Yin-Hui Yu
    Ke Yao
    International Journal of Ophthalmology, 2020, (01) : 49 - 53
  • [42] Comparative clinical outcomes of Tecnis toric IOL implantation in femtosecond laser-assisted cataract surgery and conventional phacoemulsification surgery
    Lai, Kai-Ran
    Zhang, Xiao-Bo
    Yu, Yin-Hui
    Yao, Ke
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (01) : 49 - 53
  • [43] Rotational stability and clinical outcomes after implantation of a new monofocal toric intraocular lens with double C-loop design
    Chassain, C.
    Hallak, M. K.
    Lesaffre, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (06): : 571 - 580
  • [44] Association between body mass index and clinical outcomes after new-generation drug-eluting stent implantation: Korean multi-center registry data
    Kim, Byung Gyu
    Hong, Sung-Jin
    Kim, Byeong-Keuk
    Ahn, Chul-Min
    Shin, Dong-Ho
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Hong, Myeong-Ki
    Jang, Yangsoo
    ATHEROSCLEROSIS, 2018, 277 : 155 - 162