Design and evaluation of an implantable MEMS based biosensor for blood analysis and real-time measurement

被引:4
|
作者
Eidi, Amin [1 ]
机构
[1] Sahand Univ Technol, Fac Biomed Engn, Tabriz, Iran
关键词
SURFACE-PLASMON RESONANCE; CANTILEVER SENSORS; PHONONIC CRYSTAL; GOLD ELECTRODES; LIQUID SENSOR; IMMOBILIZATION; WIRELESS; MICROSYSTEM; RESONATORS; SYSTEM;
D O I
10.1007/s00542-023-05479-w
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Detection and measurement of specific molecules in person's blood is always important in determining his or her health status. Immediate diagnostic methods are essential in this regard, especially when a particular disease is spreading. In this paper, an implantable and real-time molecule detector is proposed for blood analysis which is possible to fabricate using Micro-Electro-Mechanical Systems (MEMS) technology. Inspired by mechanical resonator sensors which are proposed to droplet analysis for lab-on-a-chip applications, a design based on a micro-mechanical resonator is proposed in this work as an implantable biosensor. It can be used inside a needle and its application is suggested in this paper. In order to evaluate the quality of the proposed design, simulations are performed by COMSOL and the results are presented. Also, the fabrication method of this design is presented.
引用
收藏
页码:857 / 864
页数:8
相关论文
共 50 条
  • [21] Real-Time Measurement of Endosomal Acidification by a Novel Genetically Encoded Biosensor
    Serresi, Michela
    BIOPHYSICAL JOURNAL, 2010, 98 (03) : 439A - 439A
  • [22] Real-time reliability evaluation based on damaged measurement degradation data
    王小林
    蒋平
    郭波
    程志君
    Journal of Central South University, 2012, 19 (11) : 3162 - 3169
  • [23] Real-time measurement of endosomal acidification by a novel genetically encoded biosensor
    Serresi, Michela
    Bizzarri, Ranieri
    Cardarelli, Francesco
    Beltram, Fabio
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (04) : 1123 - 1133
  • [24] Real-time reliability evaluation based on damaged measurement degradation data
    Wang Xiao-lin
    Jiang Ping
    Guo Bo
    Cheng Zhi-jun
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2012, 19 (11) : 3162 - 3169
  • [25] Real-time reliability evaluation based on damaged measurement degradation data
    Xiao-lin Wang
    Ping Jiang
    Bo Guo
    Zhi-jun Cheng
    Journal of Central South University, 2012, 19 : 3162 - 3169
  • [26] MEMS based Design and Analysis of a Biosensor for Detection of Hepatitis Virus
    Moudgil, Akshay
    Singh, K. K.
    Swaminathan, Sundaram
    2015 IEEE 15TH INTERNATIONAL CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO), 2015, : 805 - 808
  • [27] Approaching near real-time biosensing: Microfluidic microsphere based biosensor for real-time analyte detection
    Cohen, Noa
    Sabhachandani, Pooja
    Golberg, Alexander
    Konry, Tania
    BIOSENSORS & BIOELECTRONICS, 2015, 66 : 454 - 460
  • [28] Analysis of a GMR-Based Plethysmograph transducer and its Utility for Real-time Blood Pressure Measurement
    Chugh, Vinit Kumar
    Kalyan, Kubera
    Anoop, C. S.
    Patra, Amit
    Negi, Shubham
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 1704 - 1707
  • [29] Evaluation of novel micro-electro-mechanical sensors (MEMS) for measuring real-time blood coagulation
    Pasi, J.
    Langley, K.
    Booth, J.
    Djakov, V.
    Dunn, R.
    Jones, G.
    HAEMOPHILIA, 2008, 14 : 26 - 26
  • [30] Machine Learning Methods for Real-Time Blood Pressure Measurement Based on Photoplethysmography
    Xie, Qingsong
    Wang, Guoxing
    Peng, Zhengchun
    Lian, Yong
    2018 IEEE 23RD INTERNATIONAL CONFERENCE ON DIGITAL SIGNAL PROCESSING (DSP), 2018,