Finite element biomechanical analysis of 3D printed intervertebral fusion cage in osteoporotic population

被引:1
|
作者
Wu, Jincheng [1 ]
Miao, Jun [2 ]
Chen, Guangdong [2 ]
Xu, Hanpeng [3 ]
Wen, Wangqiang [4 ]
Xu, Haoxiang [5 ]
Liu, Lizhu [1 ]
机构
[1] Hainan Med Univ, Dept Emergency Trauma Surg, Affiliated Hosp 2, 48 Baishuitang Rd, Haikou 571700, Hainan, Peoples R China
[2] Tianjin Univ, Tianjin Hosp, Tianjin, Peoples R China
[3] Huazhong Univ Sci & Technol, Wuhan, Hubei, Peoples R China
[4] Hainan Med Univ, Affiliated Hosp 1, Haikou, Hainan, Peoples R China
[5] Second Peoples Hosp Hefei, Hefei, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Interbody fusion; Osteoporosis; Lumbar spine; Finite element model; 3D printed cage; Instrumentation failure; BONE-MINERAL DENSITY; LUMBAR SPINE; STRUCTURAL-PROPERTIES; DISC DEGENERATION; INTERBODY FUSION; SUBSIDENCE; IMPROVES; OUTCOMES; DISEASE; MODEL;
D O I
10.1186/s12891-024-07221-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectiveTo study the biomechanical characteristics of each tissue structure when using different 3D printing Cage in osteoporotic patients undergoing interbody fusion.MethodsA finite element model of the lumbar spine was reconstructed and validated with regarding a range of motion and intervertebral disc pressure from previous in vitro studies. Cage and pedicle screws were implanted and part of the lamina, spinous process, and facet joints were removed in the L4/5 segment of the validated mode to simulate interbody fusion. A 280 N follower load and 7.5 N center dot m moment were applied to different postoperative models and intact osteoporotic model to simulate lumbar motion. The biomechanical characteristics of different models were evaluated by calculating and analyzing the range of motion of the fixed and cephalic adjacent segment, the stress of the screw-rod system, the stress at the interface between cage and L5 endplate, and intervertebral disc pressure of the adjacent segment.ResultsAfter rigid fixation, the range of motion of the fixed segment of model A-C decreased significantly, which was much smaller than that of the osteoporotic model. And with the increase of the axial area of the interbody fusion cages, the fixed segment of model A-C tended to be more stable. The range of motion and intradiscal pressure of the spinal models with different interbody fusion cages were higher than those of the complete osteoporosis model, but there was no significant difference between the postoperative models. On the other hand, the L5 upper endplate stress and screw-rod system stress of model A-C show a decreasing trend in different directions of motion. The stress of the endplate is the highest during flexion, which can reach 40.5 MPa (model A). The difference in endplate stress between models A-C was the largest during lateral bending. The endplate stress of models A and B was 150.5% and 140.9% of that of model C, respectively. The stress of the screw-rod system was the highest during lateral bending (model A, 102.0 MPa), which was 108.4%, 102.4%, 110.4%, 114.2% of model B and 158.5%, 110.1%, 115.8%, 125.4% of model C in flexion, extension, lateral bending, and rotation, respectively.ConclusionsFor people with osteoporosis, no matter what type of cage is used, good immediate stability can be achieved after surgery. Larger cage sizes provide better fixation without significantly increasing ROM and IDP in adjacent segments, which may contribute to the development of ASD. In addition, larger cage sizes can disperse endplate stress and reduce stress concentration, which is of positive significance in preventing cage subsidence after operation. The cage and screw rod system establish a stress conduction pathway on the spine, and a larger cage greatly enhances the stress-bearing capacity of the front column, which can better distribute the stress of the posterior spine structure and the stress borne by the posterior screw rod system, reduce the stress concentration phenomenon of the nail rod system, and avoid exceeding the yield strength of the material, resulting in the risk of future instrument failure.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Optimization of 3D printed osteochondral tissue geometries using finite element analysis
    Bagwan, J. K.
    Jawale, Kishore
    Ahuja, B. B.
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 5197 - 5201
  • [22] Biomechanical evaluation of autologous bone-cage in posterior lumbar interbody fusion: a finite element analysis
    Zhu, Haodong
    Zhong, Weibin
    Zhang, Ping
    Liu, Xiaoming
    Huang, Junming
    Liu, Fatai
    Li, Jian
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [23] Biomechanical evaluation of autologous bone-cage in posterior lumbar interbody fusion: a finite element analysis
    Haodong Zhu
    Weibin Zhong
    Ping Zhang
    Xiaoming Liu
    Junming Huang
    Fatai Liu
    Jian Li
    BMC Musculoskeletal Disorders, 21
  • [24] Biomechanical Comparison of Optimal Shapes for the Cervical Intervertebral Fusion Cage for C5-C6 Cervical Fusion Using the Anterior Cervical Plate and Cage (ACPC) Fixation System: A Finite Element Analysis
    Wang, Jiajia
    Qian, Zhihui
    Ren, Luquan
    MEDICAL SCIENCE MONITOR, 2019, 25 : 8379 - 8388
  • [25] Biomechanical Analysis of Lumbar Interbody Fusion Cages With Various Elastic Moduli in Osteoporotic and Non-osteoporotic Lumbar Spine: A Finite Element Analysis
    Zou, Da
    Yue, Lihao
    Fan, Zheyu
    Zhao, Yi
    Leng, Huijie
    Sun, Zhuoran
    Li, Weishi
    GLOBAL SPINE JOURNAL, 2024, 14 (07) : 2053 - 2061
  • [26] BIOMECHANICAL ANALYSIS OF THE INTERVERTEBRAL DISC IMPLANT USING THE FINITE ELEMENT METHOD
    Kajzer, W.
    Kajzer, A.
    Pindycki, I.
    ADVANCES IN MATERIALS SCIENCE, 2015, 15 (03): : 57 - 66
  • [27] Biomechanical Evaluation of Intervertebral Fusion Process After Anterior Cervical Discectomy and Fusion: A Finite Element Study
    Shen, Yi-Wei
    Yang, Yi
    Liu, Hao
    Qiu, Yue
    Li, Ming
    Ma, Li-Tai
    Gan, Fang-Ji
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [28] Biomechanical effects of metastasis in the osteoporotic lumbar spine: A Finite Element Analysis
    Giuseppe Salvatore
    Alessandra Berton
    Hugo Giambini
    Mauro Ciuffreda
    Pino Florio
    Umile Giuseppe Longo
    Vincenzo Denaro
    Andrew Thoreson
    Kai-Nan An
    BMC Musculoskeletal Disorders, 19
  • [29] Biomechanical effects of metastasis in the osteoporotic lumbar spine: A Finite Element Analysis
    Salvatore, Giuseppe
    Berton, Alessandra
    Giambini, Hugo
    Ciuffreda, Mauro
    Florio, Pino
    Longo, Umile Giuseppe
    Denaro, Vincenzo
    Thoreson, Andrew
    An, Kai-Nan
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [30] An analysis of clinical application effects of 3d-printed act titanium trabecular intervertebral fusion cage in posterior lumbar interbody fusion (PLIF)
    Li, Zhijun
    Wang, Hong
    Wang, Zhaoqi
    Qi, Zhiming
    Yao, Qi
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2024, 40 (08) : 1791 - 1796