Optimization of Automated Radiosynthesis of Gallium-68-Labeled PSMA11 with Two [68Ge]Ge/[68Ga]Ga Generators: Fractional Elution or Prepurification?

被引:1
|
作者
Durieux, Flore [1 ,2 ]
Dekyndt, Berengere [1 ,2 ,3 ]
Legrand, Jean-Francois [1 ,2 ]
Rogeau, Antoine [2 ]
Malek, Emmanuel [4 ]
Semah, Franck [2 ,5 ]
Odou, Pascal [1 ,3 ]
Benesova-Schaefer, Martina
机构
[1] CHU Lille, Inst Pharm, F-59000 Lille, France
[2] CHU Lille, Nucl Med Dept, F-59000 Lille, France
[3] Univ Lille, EA 7365, GRITA, Grp Rech Formes Injectables & Technol Associees, F-59000 Lille, France
[4] CH Valenciennes, Inst Pharm, Radiopharm Unit, F-59300 Valenciennes, France
[5] Univ Lille, INSERM, U1171, F-59000 Lille, France
关键词
radiopharmacy; Ga-68]Ga-PSMA-11; double elution; CANCER;
D O I
10.3390/ph16111544
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Prostate cancer is one of the most common forms of cancer in men. An imaging technique for its diagnosis is [Ga-68]-prostate-specific membrane antigen ([Ga-68]Ga-PSMA-11) positron emission tomography (PET). To address the increasing demand for [Ga-68]-labeled peptides and reduce the cost of radiosynthesis, it is therefore necessary to optimize the elution process of [Ge-68]Ge/[Ga-68]Ga generators. This study aims to identify the most effective approach for optimizing radiosynthesis using double elution in parallel of two [Ge-68]Ge/[Ga-68]Ga generators. Two methods have been tested: one using prepurification, and the other using fractionated elution. Five synthesis sequences were conducted using each method. The mean labeling yields for double elution with prepurification were 45.8 +/- 29.4 (mean +/- standard deviation) and none met the required criteria. The mean labeling yields for the fractionated double elution were 97.5 +/- 1.9 (mean +/- standard deviation) meeting the criteria, significantly superior to the prepurification method (p = 0.012), and similar to those of simple elution. This study showed that fractionated double elution from [Ge-68]Ge/[Ga-68]Ga generators produced a significantly higher labeling yield than double elution with prepurification, resulting in a larger activity recovered via radiosynthesis, thereby allowing more diagnostic tests to be performed.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Preparation of 68Ge/68Ga Generator with a Binary Ga/Ag Electrodepositions as Solid Target
    Wu-Long Cheng
    Yun Jao
    Chung-Shin Lee
    Ai-Ren Lo
    Journal of Radioanalytical and Nuclear Chemistry, 2000, 245 : 25 - 30
  • [42] Preparation of [68Ga]PSMA-11 for PET-CT imaging using a manual synthesis module and organic matrix based 68Ge/68Ga generator
    Nanabala, Raviteja
    Anees, Muhammed K.
    Sasikumar, Arun
    Joy, Ajith
    Pillai, M. R. A.
    NUCLEAR MEDICINE AND BIOLOGY, 2016, 43 (08) : 463 - 469
  • [43] Development of adsorption/desorption material for novel 68Ge/68Ga generator
    Lee, J.
    Park, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S121 - S121
  • [44] A new 68Ge/68Ga generator based on CeO2
    Institute of Nuclear Research, Academia Sinica, Shanghai 201800, China
    J. Radioanal. Nucl. Chem., 4 (233-238):
  • [45] A new 68Ge/68Ga generator based on CeO2
    J Radioanal Nucl Chem, 4 (233):
  • [46] 68Ge/68Ga发生器的临床应用
    黄钱焕
    潘栋辉
    徐宇平
    盛洁
    王彦婷
    杨敏
    同位素, 2017, 30 (04) : 270 - 275
  • [47] How is 68Ga Labeling of Macrocyclic Chelators Influenced by Metal Ion Contaminants in 68Ge/68Ga Generator Eluates?
    Simecek, Jakub
    Hermann, Petr
    Wester, Hans-Juergen
    Notni, Johannes
    CHEMMEDCHEM, 2013, 8 (01) : 95 - 103
  • [48] Characterization of a tin dioxide based 68Ge/68Ga generator and study on 68Ga radiolabelling of DOTA-NOC
    Chen Bao Jun
    Shi Cui Yan
    Wen Kai
    Fu Hong Yu
    Shen Yi Jia
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2013, 56 : S195 - S195
  • [49] A SIMPLE, ROBUST, FULLY AUTOMATED SYSTEM FOR DUAL 68GE/68GA GENERATOR RADIOPHARMACEUTICAL PRODUCTION
    Nguyen, B.
    Poniger, S.
    Sachinidis, J.
    INTERNAL MEDICINE JOURNAL, 2019, 49 : 32 - 33
  • [50] Quantitative online isolation of 68Ge from 68Ge/68Ga generator eluates for purification and immediate quality control of breakthrough
    Eppard, Elisabeth
    Loktionova, Natalia S.
    Roesch, Frank
    APPLIED RADIATION AND ISOTOPES, 2013, 82 : 45 - 48